Choose the BEA FLATSCAN manual that matches the complete model name on your sensor. The BEA LZR-FLATSCAN SW and BEA LZR-FLATSCAN 3D SW serve automatic pedestrian swing doors, but their setup instructions differ. Use the official BEA LZR-FLATSCAN SW manual or BEA LZR-FLATSCAN 3D SW manual before planning the installation or changing settings.
Keep the door operator’s manual alongside the sensor instructions: the sensor’s detection field, electrical outputs, and the operator’s response must work together.
Match the BEA FLATSCAN Model to Its Application
BEA uses the FLATSCAN name across several laser sensors. The letters after the name identify different products and applications. Check the label on the installed sensor rather than relying on a shortened invoice description.
|
Model |
Intended application |
Key distinction |
|---|---|---|
|
BEA LZR-FLATSCAN SW |
Automatic pedestrian swing doors |
One detection curtain covers the door leaf and hinge area. |
|
BEA LZR-FLATSCAN 3D SW |
Automatic pedestrian swing doors |
Four detection curtains and virtual push button functionality. |
|
BEA LZR-FLATSCAN S |
Industrial doors, gates, and barriers |
Laser presence detection; marketed as an alternative to an inductive loop. |
The BEA LZR-FLATSCAN SW is a laser time-of-flight presence sensor for automatic pedestrian swing doors. It does not detect vehicles through a buried inductive loop. For an industrial gate project where cutting the pavement is a concern, review the separate BEA LZR-FLATSCAN S application instead of applying pedestrian-door instructions.

Download the Correct BEA FLATSCAN Manual PDF
For the BEA LZR-FLATSCAN SW, the linked United States user guide is document 75.5947.10, dated August 13, 2024. The BEA LZR-FLATSCAN SW downloads page also provides a quick start guide, wiring matrix, and application notes. Use the full guide when you need installation conditions, troubleshooting, or the door coverage chart.
For the BEA LZR-FLATSCAN 3D SW, the linked guide is document 75.0036.09, dated March 23, 2026, for software version 0103 and higher. Match that version to the tracking label on the product. Check the BEA LZR-FLATSCAN 3D SW downloads page when confirming the appropriate revision.
A regional or older BEA LZR-FLATSCAN manual can use a different configuration chart. For example, the reviewed United States BEA LZR-FLATSCAN SW guide assigns DIP 3 to output configuration, while the reviewed BEA LZR-FLATSCAN 3D SW guide assigns DIP 3 to background detection. Copying a switch setting without checking the model can change the wrong function.
Confirm the Door Configuration Before Mounting
Identify whether the door is full energy or low energy, which side each sensor will monitor, and whether the installation uses one sensor or a connected pair. The BEA LZR-FLATSCAN SW manual specifies sensors on both sides for full-energy applications and allows a single approach-side sensor in certain low-energy arrangements. Have the technician confirm the complete arrangement for the door.
Before selecting hardware, check:
-
Mounting clearance through the full door movement, including the closer arm, frame, hinge area, and any finger guards.
-
Door dimensions against the sensor’s coverage chart. A maximum diagonal range is not a guarantee of coverage for every height and width.
-
The mounting method and accessories for the actual door material, especially a frameless glass door.
-
Whether the order is a complete kit or a replacement sensor, including the required harnesses and mounting components.
All Security Equipment’s BEA LZR-FLATSCAN SW low-energy right-door kit and BEA LZR-FLATSCAN 3D SW left-and-right kit identify different package configurations. Match the package to the installer’s plan before ordering.
Match BEA FLATSCAN Wiring to the Door Operator
The BEA LZR-FLATSCAN SW manual specifies a DC supply and distinguishes the stop output on the swing side from the reopening output on the approach side. Its test input is another separate connection. The installer must match these functions to the operator’s terminals and monitoring requirements.
Use the appropriate BEA wiring matrix together with the operator manual. Even the sequence for connecting outputs during setup differs between the reviewed BEA LZR-FLATSCAN SW and BEA LZR-FLATSCAN 3D SW guides. Avoid treating a wire color or terminal example from another model as a universal wiring diagram.
Teach In the BEA FLATSCAN Detection Field
Teach-in is the sensor’s learning process for its detection field. For the BEA LZR-FLATSCAN SW, prepare the door and sensor as the matching manual describes, remove the laser-window protector at the correct stage, and keep the detection area clear. The procedure uses a hand gesture at the leading edge to establish field width.
A low-energy installation using a single BEA LZR-FLATSCAN SW sensor can use the static-mode procedure in Appendix 2. That mode learns door dimensions without learning the surrounding environment. Confirm the applicable procedure before assuming that guide rails or nearby objects have been learned.
After teach-in, the technician must check the detection fields and actual door response using the applicable manufacturer test procedure. Repeat the learning and testing process after changing the sensor angle, position, or environment. A completed learning sequence alone does not demonstrate that every required detection area works correctly.
Troubleshoot BEA FLATSCAN LED Signals and Detection
Record the sensor model, serial number, CAN number, door operator model, and exact LED behavior before changing settings. In the BEA LZR-FLATSCAN SW manual, different orange flash counts identify different fault categories; the color alone does not identify the cause.
For unwanted detections, check whether the flexible cable enters the field or whether dirt or an obstruction covers the laser window. For power, wiring, or communication faults, use the matching troubleshooting chart. Have the technician confirm the cause before changing field dimensions or detection settings.
On the BEA LZR-FLATSCAN SW, Service Mode temporarily disables the detection fields. An unlit LED can occur in that mode, so do not treat it as proof that the sensor is ready for normal service. Finish with the required operational checks and restore the installation to its intended operating state.
When replacement hardware is needed, compare the model and package requirements with All Security Equipment’s BEA sensor selection. Preserve the model and revision information in the service record so the next technician can use the correct manual.
BEA FLATSCAN Manual Questions
Can I use the BEA LZR-FLATSCAN SW manual for the BEA LZR-FLATSCAN 3D SW?
Use the guide for the exact model and software version. The BEA LZR-FLATSCAN 3D SW has features and setup requirements that differ from the BEA LZR-FLATSCAN SW, including virtual push button functionality.
Is a BEA FLATSCAN sensor an inductive loop detector?
BEA FLATSCAN sensors use laser technology, and the BEA LZR-FLATSCAN S is marketed as an industrial alternative to an inductive loop. The BEA LZR-FLATSCAN SW and BEA LZR-FLATSCAN 3D SW serve pedestrian swing doors.
Does teach-in replace the final installation test?
No: teach-in configures the detection field, while the final test checks field coverage and the door’s response. BEA also calls for renewed teach-in and testing after changes to the sensor angle, position, or environment.