Documentation Information

Manufacturer
LiftMaster
Model
CAPXM
Equipment type
Smart Video Intercom M, cloud based access control with integrated video camera (controls up to two doors or gates)
Document type
Installation Manual (English, French, and Spanish in one PDF; this page presents the English version, pages 1 to 26)
Manufacturer document number
Not printed on the English pages of the manual
Manual revision
Not printed on the English pages of the manual
Source
LiftMaster CAPXM Installation Manual; see Original LiftMaster Documentation
HTML resource last updated
November 11, 2026

Common tasks: Set up a myQ Business account | Connect to the internet | Connect power | Wire a door or gate | Pair a gate operator | Parts and accessories

LiftMaster CAPXM Manual Overview

The LiftMaster CAPXM Smart Video Intercom M (Model CAPXM, branded "myQ Business Smart Video Intercom M" on the manual's cover) is, in LiftMaster's words, a cloud based access control solution that includes an integrated video camera enabling advanced video features. It has a touchscreen display, speaker, microphone, and camera, a control board, and a door board that can control up to two access points (doors or gates), each with a primary relay, an auxiliary relay, a Wiegand input, a request-to-exit input, and a status (supervised) input. It also has a built-in LiftMaster Passport receiver (Security+ 2.0) that can communicate wirelessly with compatible gate operators.

LiftMaster's manual is organized in four parts after the introduction: (1) pre-install (myQ Business account), (2) install (knockouts, mounting, ground, power), (3) network, and (4) access control (gate and door wiring, RFID reader, Wiegand output, postal lock, wiring diagram, parts, accessories). This page follows the same order. The manual has no troubleshooting chart or diagnostic code table, so this page has none; see the Control Board Overview for the diagnostic LEDs LiftMaster labels.

Control Board Overview

LiftMaster's overview illustration of the control board (page 5, front and back views) labels these items; the illustration is not reproduced here.

  • Connections: power (+ and -), expansion, Wi-Fi antenna connection, speaker, microphone, touch panel, display data, Security+ 2.0 radio antenna, USB Ethernet, USB (camera), postal lock, and door board.
  • Switches and diagnostic LEDs: voltage input, admin mode (switch #1; see Connect Internet), not used, +12 volts, +5 volts, +3.3 volts, +3.4 volts, and diagnostic.
  • Coin cell battery: labeled on the back view.

The CAPXM overview illustration (page 4) labels the display (touchscreen), speaker (two), lock, provisions for a postal lock (two), provision for a card reader, camera window, microphone (two), tether, video camera, control board, and door control board.

Door Board Overview

The CAPXM has a combination of access control inputs and outputs on the door board that work together to control up to 2 access points (page 6). Each of Door 1 and Door 2 has a primary relay, auxiliary relay, Wiegand input, request-to-exit input, and status input, and the door board has a Wiegand output.

Swipe sideways to see all columns.

CAPXM door board inputs and outputs (page 6)
Input / output Used for
Relay output 1 and relay output 2 Gate operator, door strikes, maglocks, lights (for control-only; power to be provided by an external power supply), alarm shunt.
Wiegand output 1 and Wiegand output 2 Standard 26-bit, 30-bit Wiegand, HID 37-bit with Facility Code, Transcore 37-bit, 32-bit MiFare.
Supervised input 1 and supervised input 2 Closed door sensor (supervised EOL or unsupervised), closed limit gate sensor (supervised EOL or unsupervised), open limit gate sensor (supervised EOL or unsupervised).

Per the manual, only the 26-bit Wiegand protocol is compatible in UL installations. See pages 17 and 19 of the manual for wiring examples, and Gate Access (Wired) and Door Access below.

What Is in the CAPXM Carton

LiftMaster's carton inventory (page 7) lists these items (the installation manual is provided but not shown):

  • Power supply
  • Goose-neck gasket
  • PK625 keys (2)
  • Ferrite core
  • S10K30MOV (metal oxide varistor) (4)
  • 1N4005 diode kit (4)
  • Radio antenna (Security+ 2.0) and cable
  • Wi-Fi antenna (labeled "Wi-Fi" in the carton illustration)
  • Installation manual

Tools Needed

  • PH2 Phillips screwdriver
  • Precision 1/8 in. flat or PH0 Phillips screwdriver
  • 1/4 in. nut driver
  • Drill/driver and 7/64 in. drill bit
  • Hammer drill bits for the drill/driver
  • RJ45 crimping pliers
  • Multimeter and measuring tape
  • Conduit bender and conduit cutter/reamer
  • Hack saw
  • Center punch tool and hammer

Additional tools LiftMaster recommends: network LAN cable tester, Wi-Fi analyzer app (smartphone app), network analyzer software, a computer with an Ethernet port, and an Ethernet patch cable.

All Security Equipment note. The product page for the CAPXM states that every LiftMaster Smart Access Solution requires a monthly myQ Community subscription, that the CAPXM needs a wired internet connection or Wi-Fi to function, and that, because of billing restrictions, it cannot work outside the USA and Canada. See the LiftMaster CAPXM product page for current details.

Source: LiftMaster CAPXM installation manual (English), pages 4 to 7.

Back to contents

LiftMaster CAPXM Specifications

Swipe sideways to see all columns.

CAPXM system specifications as printed by LiftMaster (page 8)
Specification Value
CAPXM capacity Resident capacity 50,000 / local event history 50,000
Supply voltage 24VDC, 60W (minimum), Class 2 output, Level VI efficiency (power supply 120VAC, 60Hz, 2A)
Operating current 0.75A (typical) at 24VDC, 3A max at 15VDC
Surge suppression EFT: 2 kV power line, ESD: 15 kV HBM / 8 kV direct / 200V MM
CAPXM operating temperature range -29°C to 54°C (-20°F to 130°F)
Enclosure Carbon steel and aluminum
Storage and shipping temperature range -40°C to 65°C (-40°F to 149°F)
Wiegand inputs (2) 26-bit, *30-bit, *32-bit Mifare, *37-bit with and without facility code, and ASCII (for keypads). 12VDC, 250mA power output (per input).
Relay outputs 2 primary and 2 auxiliary relay outputs, SPDT, rated load 3A at 30VDC (each)
Accessory compatibility Refer to the accessory page for compatible accessories
Network compatibility 10/100 Ethernet
Wi-Fi compatibility 802.11b/g/n @ 2.4 GHz
Wi-Fi security Compatible with routers using WPA3 Personal and WPA2 Personal (AES).
Wi-Fi range Up to 250 feet (76.2 m), open air/line-of-sight to front of panel (range will vary depending on obstructions)
Built-in LiftMaster Passport receiver Security+ 2.0
Wireless communication to gate operator Up to 750 feet (228.6 m), open air/line-of-sight (range will vary depending on obstructions). Compatible with LiftMaster Security+ 2.0 gate operators, 2018 LiftMaster gate operators (firmware v4.4 and later), and HD operators (firmware v3.3 or later). NOT compatible with LiftMaster barrier gate operators.
CAPXM video camera 1080p, viewing angle 135 degree diagonal, up to 1,000 30-second temporary video events stored locally

LiftMaster's note: *Only the 26-bit Wiegand protocol is compatible in UL installations. Wi-Fi and wireless ranges were not evaluated by UL.

Documentation note. The English specifications give the storage and shipping temperature range as -40°C to 65°C (-40°F to 149°F), while the Spanish version of the same manual prints -40°C to 60°C (-40°F to 140°F). This page follows the English text; confirm with LiftMaster if the storage limit matters for your project.

CAPXM Dimensions

LiftMaster's dimensions drawing (page 8) shows front, side, back, and bottom views with these printed dimensions: 6-1/8 in (15.6 cm), 17 in (43.2 cm), 15 in (38.1 cm), 8.43 in (21.4 cm), 4 in (10.2 cm), and 2.25 in (5.7 cm), plus two 3/4 in. conduit knockouts and one 1-1/4 in. conduit knockout. The drawing is not reproduced here; see page 8 of the original manual to match each dimension to its view.

Source: LiftMaster CAPXM installation manual (English), page 8.

Back to contents

Important Safety Information

Safety Warnings From the CAPXM Manual

To reduce the risk of SEVERE INJURY or DEATH:

  • Disconnect power at the fuse box BEFORE proceeding.
  • To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging.
  • ALL electrical connections MUST be made by a qualified individual.
  • ALL power and control wiring MUST be run in separate conduit.
  • All power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled.
  • The CAPXM shall be installed in accordance with the National Electrical Code and all local codes.

To protect against fire and electrocution:

  • Disconnect power BEFORE installing or servicing the CAPXM.
  • NEVER connect a keypad/reader or lock to doors without first consulting the applicable fire code.
  • You MUST consult with, and get approval from, local fire officials BEFORE installing locks or devices on ANY doors that may be fire exits.
  • Use of egress push buttons may not be legal. Single action exits may be required.
  • ALWAYS obtain proper permits and approvals in writing BEFORE installing equipment.

DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so may cause interference with the operation of panic hardware.

LiftMaster's page 2 also reviews its safety symbols (mechanical and electrical hazards) and signal words, which alert you to the possibility of serious injury or death, or of damage to property or product, if the warnings are not followed. It includes a California Proposition 65 warning: this product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm (www.P65Warnings.ca.gov).

All Security Equipment note. Fire exits, egress, and fail-secure installations are governed by local codes and the authority having jurisdiction. Follow the manual and local requirements; this page is not a substitute for them.

Source: LiftMaster CAPXM installation manual (English), page 2.

Back to contents

CAPXM Wire Specifications and Internet Requirements

Wire Specifications

LiftMaster says to use this chart to pull wires in preparation for installation, and to check the national and local building codes BEFORE installation (page 9).

Swipe sideways to see all columns.

CAPXM wire specifications and maximum run distances (page 9)
Description of wire run Wire specification Maximum run distance
Power wire, secondary DC output 2-conductor 14 AWG
2-conductor 16 AWG
2-conductor 18 AWG
Up to 300 feet (91.4 m)
Up to 200 feet (60.9 m)
Up to 100 feet (30.4 m)
Local Area Network (LAN), CAT 5e or better network cable 8-conductor, 24 AWG twisted pair 328 feet* (100 m)
Grounding the chassis (use grounding lug in the CAPXM) 12 AWG copper 12 feet (3.7 m)
Door strike 2-conductor 18-22 AWG shielded 100 - 250 feet (30.5 - 76.2 m)
Magnetic lock 2-conductor 18-22 AWG 50 - 125 feet (15.2 - 38.1 m)
Dry contact closure (most gate operators) 2-conductor 18-24 AWG shielded 500 - 2500 feet (152.4 - 762 m)
Exit request (REX) 2-conductor 18-24 AWG 500 feet (152.4 m)
Supervised input 2-conductor 18-24 AWG 500 feet (152.4 m)
Wiegand/proximity readers 7-conductor 18-22 AWG shielded 500 feet (152.4 m)

LiftMaster's notes: main power supply and control wiring MUST be run in separate conduits. Conduits must be UL approved for low and high voltage. Refer to the NEC for additional wiring requirements. Category 5e cabling is the minimum performance category recommended. Wiring shall be in accordance with the National Electrical Code (ANSI/NFPA 70), local codes, and authorities having jurisdiction.

Always provide power from a dedicated source. Plug the provided transformer into an outlet wired to its own 10 Amp minimum circuit breaker. This prevents two problems: other equipment cannot introduce spikes, noise, surges, or dips into the power circuit that will affect the system, and the system's operation will not be affected if other equipment develops a short circuit across the power line.

*CAT 5/6 network cable notes: for outdoor distances exceeding 140 feet (42.7 m), a UL497 compliant primary surge protector MUST be installed at the CAPXM. Distances exceeding 328 feet (100 m) may be accommodated with additional hardware (available through third-party sources).

Internet Requirements

When selecting a router, use the following information to ensure compatibility (page 10). The CAPXM can be connected to a router through a wired connection or Wi-Fi. LiftMaster recommends a minimum upload/download speed of 5 Mbps for each CAPXM supporting video camera feeds. This upload speed should be met when considering the use of other devices on the network, like cameras and computers.

  • Wi-Fi security compatibility: WPA3 Personal and WPA2 Personal (AES).
  • Wi-Fi protocols: 802.11b, 802.11g, and 802.11n @ 2.4 GHz.
  • Wi-Fi extenders: DO NOT use Wi-Fi extender devices. They may introduce latency in the connection, leading to choppy or lost video transmission.
  • Signal strength: if using a Wi-Fi signal strength tool or app, a continuous Wi-Fi signal strength of at least -65 dBm (numbers closer to zero are stronger) at the CAPXM must be guaranteed to ensure an acceptable connection to the local network. When checking signal strength in CAPXM admin mode, LiftMaster recommends at least two bars, as shown on the CAPXM screen.
  • If two bars are not available: relocate the router or the antenna, or use accessory WFAEXT (Wi-Fi Antenna Extension Kit, 15 ft) to move the CAPXM antenna higher up or to a location resulting in two or more bars.
  • Hidden networks: hidden network SSIDs are not supported. The network must be selectable from the CAPXM display.
  • Secondary authentication: Wi-Fi networks requiring secondary authentication are not supported (for example, hotel and airport Wi-Fi).

Source: LiftMaster CAPXM installation manual (English), pages 9 and 10.

Back to contents

myQ Business Account Setup

LiftMaster's pre-install step (page 11) sets up the myQ Business account the CAPXM needs. If you have an existing myQ account, your myQ Business account will have the same password; go to myQBusiness.com and log in.

Set up a myQ Business account

  1. If you do not have a myQ Business account, call LiftMaster Customer Care at 800.323.2276 to activate one. LiftMaster also says to be prepared by reviewing the information required on its Installation Readiness Survey.
  2. You will get a welcome email from LiftMaster. Accept the invitation and register or log in to your account.
  3. Set up the facility, select a subscription plan, add residents, and add credentials (refer to the available Help in myQ Business).
  4. Continue with the installation of the CAPXM in this manual.

For support, LiftMaster lists 800.528.2806 or support.partner.liftmaster.com/s/community-access-support. A SIP account is required for the calling function: LiftMaster only supports Phone.com for video calling features and cannot guarantee or support a third party SIP provider's compatibility for voice-only calling. For myQ Business programming, LiftMaster directs you to www.myqbusiness.com (page 3).

Documentation note. Page 11 says to review the Installation Readiness Survey but, in the English text, does not print a link or file name for it. LiftMaster's CAPXS manual prints a survey link (https://p.widencdn.net/oyeejd/114a4574); check LiftMaster.com or the original page 11 for the survey that applies to the CAPXM.

Source: LiftMaster CAPXM installation manual (English), page 11.

Back to contents

LiftMaster CAPXM Installation

LiftMaster's installation steps are: Step 1, remove knockouts; Step 2, mount the CAPXM; Step 3, install the ground; Step 4, connect power. Network setup then follows (connect internet and validate setup), and then the access control wiring.

Remove Knockouts (Step 1)

To prevent damage to the CAPXM from moisture or water:

  • DO NOT install during rain. Internal components MUST be kept free of water and moisture.
  • BEFORE opening the front cover of the CAPXM, remove ANY accumulated water from the top of the CAPXM.

To prevent damage to ANY internal components: DO NOT attempt to remove the knockouts with a hammer. Banging on the knockouts may result in shock to the circuit boards, which could cause permanent damage.

Step 1, remove knockouts

  1. Prepare the work surface by laying down a cloth or other protective material.
  2. Lay the CAPXM face down on the protective material.
  3. Identify which knockouts need to be removed based on your application.
  4. Use a center punch tool to remove the knockouts from the outside of the box inward using an appropriately sized punch and hammer. Be careful when removing the knockouts to avoid damaging the CAPXM components.

LiftMaster's illustration marks each knockout with a letter: E = electrical wiring, P = pedestal mount, R = recess/surface mount, S = Security+ 2.0 radio antenna, and W = Wi-Fi antenna.

Source: LiftMaster CAPXM installation manual (English), page 12.

Back to contents

Mount the CAPXM (Step 2)

Step 2, mount the CAPXM

  1. Attach the goose-neck gasket (provided) if mounting to a goose-neck.
  2. Mount the CAPXM securely to a flat surface or pedestal with appropriate 1/4 in. hardware, taking care to route wiring through the appropriate knockouts. Stainless steel hardware is recommended. Use of zinc plated or galvanized hardware is at risk for galvanic corrosion.
  • Cover clearance: ensure the cover can fully open to allow access after the installation is complete. Allow 1/8 in. (3.175 mm) of space between the bottom of the CAPXM and the wall if flush-mounting the CAPXM without the trim kit.
  • ADA compliance: when mounting the CAPXM at a pedestrian entrance, to meet ADA compliance, mount the top of the CAPXM screen no higher than 54 inches from the ground.
  • Sealing: make sure the CAPXM is properly sealed to prevent damage from moisture.

LiftMaster's illustrations show a pedestal mount and a surface mount.

Source: LiftMaster CAPXM installation manual (English), page 13.

Back to contents

Install the Ground (Step 3)

Important (LiftMaster): an earth ground rod is strongly recommended and should be no further than 12 feet (3.7 m) from the CAPXM, using a minimum of 12 gauge wire in most cases. The type and length of earth ground rods vary by region. Contact the AHJ (Authority Having Jurisdiction) in the municipality where you plan to install the CAPXM for correct grounding materials and installation procedures. A proper ground is critical to minimizing the risk of damage to the CAPXM from electrical transients.

Step 3, install the ground

  1. Connect the ground wire (12 AWG or larger) to the CAPXM main earth ground connection.
  2. Run the wire from the CAPXM to a suitable earth ground.

Note: shield connections on boards should not be connected to the main earth ground connection. Keep the ground wire as straight as possible, and check national and local codes for the proper depth. To AVOID damaging gas, power, or other underground utility lines, contact underground utility locating companies BEFORE digging.

LiftMaster's illustration shows 12 AWG minimum ground wire to an earth ground rod, with other ground sources within 12 feet of the access control panel (the existing electrical system ground, or a metallic cold water pipe) and a maximum of 12 feet (3.7 m).

Source: LiftMaster CAPXM installation manual (English), page 14.

Back to contents

Connect Power (Step 4)

  • DO NOT use ANY power supply other than those supplied with your CAPXM.
  • DO NOT power electronic strikes and latches with the same power supply used to power the access control panel; doing so will cause DAMAGE to the CAPXM. Use ONLY a UL listed burglar alarm or access control system to power electronic strikes and latches.
  • DO NOT connect the power supply to a switched outlet or otherwise controlled AC outlet.
  • DO NOT connect the power supply to the 120 Vac outlet until ALL wiring is completed.
  • Install the transient noise suppression device (MOV) supplied with the CAPXM for AC powered devices, and a diode for DC powered devices.
  • DISCONNECT the power supply from the 120 Vac outlet prior to removing or attaching the terminal block to the control board.

The outlet for the CAPXM MUST be an external dedicated 120 Vac outlet, wired back to its own 10 Amp minimum circuit breaker. Maximum wire run distances for the power wiring:

Swipe sideways to see all columns.

CAPXM power wire run (page 15)
Wire specification Maximum run distance
14 AWG Up to 300 feet (91.4 m)
16 AWG Up to 200 feet (60.9 m)
18 AWG Up to 100 feet (30.4 m)

Step 4, connect power

  1. Connect 14-18 AWG wire to the stripped secondary DC output wires on the power supply. Black is negative and red is positive.
  2. Remove the PWR INPUT terminal block from the control board.
  3. Connect the power supply wires to the PWR INPUT terminal block (red to +24V and black to GND). Reattach the terminal block to the control board.
  4. Plug the power supply into a 120 Vac outlet after all connections have been made.
  5. Close the CAPXM door.

Note: the green LED on the door board will blink and the green LEDs on the control board will light solid when powered up. The CAPXM will display the LiftMaster logo while booting up. When boot up is complete, the user interface will appear.

If the power supply is installed outdoors, it must have its own approved NEMA 4 rated weatherproof electrical enclosure. Use conduit from the power supply enclosure to the controller enclosure.

Source: LiftMaster CAPXM installation manual (English), page 15.

Back to contents

Connect Internet (Network Step 1)

The CAPXM can connect to the internet with a wired connection or with Wi-Fi (wireless); see Internet Requirements. Make sure you are in Admin Mode before you connect to the internet. If you are not in Admin Mode, flip switch #1 to the ON position on the control board, press the Network tab on the CAPXM display, and press the "Change Network Settings" button. Follow the instructions for your application.

Option 1, wired connection

The Local Area Network (LAN) port is a 10/100 Ethernet interface with an RJ45 jack for connecting the CAPXM to a hub, switch, or router so it can gain internet connectivity. Use a straight (non-crossover) Cat5e or Cat6 cable, referred to as an Ethernet cable in the manual.

  1. Connect an Ethernet cable from the hub, switch, or router to the LAN port on the control board. When connected properly, the green and amber LEDs on the Ethernet port of the control board will light or flicker (the control board is located on the back of the CAPXM display). If the green LED is not lit, check the connections on the CAPXM and the Ethernet hub.
  2. On the display, select Wired Network if dynamic configuration (DHCP) is desired, or select Manual Setup for a static IP address.

Option 2, connect through Wi-Fi (wireless)

  1. On the display, select Wi-Fi Network.
  2. Select the network the CAPXM will use.
  3. Enter the password for the network.
  4. Select Login.

Additional compatibility considerations (LiftMaster): when checking signal strength in CAPXM admin mode, LiftMaster recommends at least two bars. If two bars are not available, relocate the router or the antenna, or use accessory WFAEXT (Wi-Fi Antenna Extension Kit, 15 ft). If using a Wi-Fi signal strength tool or app, a continuous signal strength of at least -65 dBm at the CAPXM must be guaranteed. Hidden network SSIDs and networks requiring secondary authentication are not supported.

LiftMaster's illustration labels the Ethernet path (LAN on the control board, router/switch, modem, Ethernet cable, 325 feet [99.1 m] maximum) and a Wi-Fi signal graphic with three ranges: -30 to -67 dBm GOOD, -66 to -85 dBm POSSIBLE, and "-86 dBm or weaker" POOR (printed as "≥ -86 dBm").

Documentation note. The manual gives two different maximum Ethernet cable lengths: 328 feet (100 m) in the wire specifications (page 9) and 325 feet (99.1 m) in the Connect Internet illustration (page 16). The text also requires a continuous signal of at least -65 dBm (pages 10 and 16), while the signal graphic shows GOOD as -30 to -67 dBm and POSSIBLE as -66 to -85 dBm, and prints the POOR range with a "≥" sign ("≥ -86 dBm") although weaker signals have more negative numbers. Treat the stronger requirement as the safer target and confirm with LiftMaster if your installation is near these limits.

Validate Setup (Network Step 2)

On the display, select each tab in Admin Mode to validate the setup (network, inputs, outputs, and so on). Once you have validated the setup, exit Admin Mode.

Source: LiftMaster CAPXM installation manual (English), page 16.

Back to contents

CAPXM Access Control Wiring

LiftMaster's manual shows wiring examples for gate access (wired, page 17), gate access (wireless, page 18), door access (page 19), an RFID reader (page 20), a Wiegand output (page 21), and a postal lock (page 21), plus a wiring diagram of the CAPXM's internal connections (page 22). All wiring pages say to disconnect power BEFORE making electrical connections. The diagrams are not reproduced on this page; use the original manual pages for terminal-level connections, and the notes below, which LiftMaster prints on the diagrams.

  • Disconnect power BEFORE making electrical connections.
  • DO NOT run high voltage power within the CAPXM enclosure.
  • DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so may cause interference with the operation of panic hardware.

Gate Access, Wired (Page 17)

Gate access can be wired to Door 1 or Door 2 on the door board. LiftMaster Security+ 2.0 gate operators can also be programmed to communicate wirelessly instead of using a wired connection (see Gate Access, Wireless). The labels on LiftMaster's example include: push button, gate operator, maglock, reader or keypad (12Vdc red, ground black, DATA 0 green, DATA 1 white, green LED orange, red LED brown), external free exit loop detector, request to exit, status (supervised, with an end-of-line resistor), primary relay, auxiliary relay (alarm bypass, light), and an RFID antenna with Wiegand output.

  • Gate operator connection: connect to the gate operator's auxiliary closed limit switch; refer to the gate operator manual. The status (supervised) connection is not applicable for wireless gate operator connections.
  • Maglock: use 18-22 AWG wire and a separate power supply (not provided). DO NOT use the controller's power supply. For DC power, install a 1N4005 diode or equivalent. For AC power, install a Siemens S10K30MOV (metal oxide varistor) (provided) or equivalent.
  • End-of-line resistor: 1k ohm.
  • RFID antenna: power it separately (power not provided); DO NOT use the controller's power supply.
  • Wiring: keep the length of unshielded wires to a minimum to avoid electrical noise. For a KPR2000 keypad, wire the pink and black (ground) wires together.
  • Light or load on the auxiliary relay: the diagram's labels include an isolation relay, a low voltage power supply, and the load, line, and neutral connections.
  • UL evaluation: the maglock and alarm bypass were not evaluated by UL.

Source: LiftMaster CAPXM installation manual (English), page 17.

Back to contents

Gate Access, Wireless (Page 18)

The CAPXM can communicate wirelessly with LiftMaster UL325 gate operators to send open commands, monitor gate position, and send email notifications if an error occurs in the operator (email notifications are configured in myQ Business). Up to 4 gate operators can be paired with the CAPXM, one for each primary and auxiliary relay. If using dual gates, program the CAPXM to the primary operator. Use of this feature requires the optional Passport antenna kit.

Pair a gate operator wirelessly

  1. Enter Admin Mode. Flip switch #1 to the ON position. For new installations, press the login button without entering information in the Admin Username and Admin Password fields.
  2. Select Outputs and Relay. Select the Outputs tab, then select the desired relay on the left-hand side (1 through 4).
  3. Press the LEARN button on the gate operator. Press and release the LEARN button on the primary operator. The green XMITTER LED will light. The operator will time out of programming mode after 180 seconds.
  4. Press the LEARN button on the gate operator again. Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light.
  5. Select LEARN on the display. Select the LEARN button on the display and the button will go from blue to red. The gate operator and the CAPXM will beep once and the NETWORK LED on the gate operator will turn off, indicating programming is successful. Four beeps or blinks indicate you are not programming to the primary operator; reattempt programming from the other operator.
  6. Validate. Validate functionality by selecting Test Relay on the CAPXM display.

LiftMaster directs you to myQBusiness.com for more information on how to set up doors for wireless linking. See also the compatibility limits in Specifications (750 feet open air, Security+ 2.0 and listed operator firmware, not compatible with barrier gate operators).

Source: LiftMaster CAPXM installation manual (English), page 18.

Back to contents

Door Access (Page 19)

Door access can be wired to Door 1 or Door 2 on the door board. The labels on LiftMaster's door access example include: push button, door strike, maglock, proximity sensor, request to exit (REX), supervised (door status) with a supervised or non-supervised door sensor, reader or keypad (12Vdc red, ground black, DATA 0 green, DATA 1 white, green LED orange, red LED brown), primary relay, auxiliary relay (alarm bypass and a light), and the isolation relay, low voltage power supply, load, line, and neutral. The diagram itself is the authority for which device connects to which terminal.

  • Maglock and door strike power: use a separate power supply (not provided). DO NOT use the controller's power supply for the maglock. Use 18-22 AWG wire.
  • Surge protection for the lock: for DC power, install a 1N4005 diode or equivalent. For AC power, install a Siemens S10K30MOV (metal oxide varistor) (provided) or equivalent.
  • Supervised input: the diagram shows an end-of-line (EOL) resistor (1k ohm) for the supervised door sensor.
  • Wiring: keep the length of unshielded wires to a minimum to avoid electrical noise. For a KPR2000 keypad, wire the pink and black (ground) wires together.
  • UL evaluation: the maglock, door strike, and alarm bypass were not evaluated by UL.

Source: LiftMaster CAPXM installation manual (English), page 19.

Back to contents

RFID Reader (Page 20)

Page 20 is the LiftMaster LMSC1000 RFID reader wiring diagram. Its labels include: the LMSC1000 RFID reader, a power transformer (24 Volts AC/DC, 1 Amp max.), an optional arming loop detector, a low voltage light, an external low voltage indicator light (optional), the gate operator (normally open and common), and the door board with Door 1 and Door 2 (Wiegand input, primary relay, auxiliary relay, request to exit, status, and Wiegand output).

  • To enable the optional arming loop detector, set switch #5 to "ON".
  • The gray, blue, and brown wires from the RFID reader are unused.

Source: LiftMaster CAPXM installation manual (English), page 20.

Back to contents

Wiegand Output (Page 21)

Disconnect power BEFORE making electrical connections. The CAPXM offers a Wiegand output capable of 26-bit transmission of the following data, and/or:

  • Success call with access granted by the resident: the CAPXM will provide a myQ Business specified facility code followed by the Directory Code of the resident that granted access.
  • Successful access through entry code: the CAPXM will provide a myQ Business specified facility code followed by the successful entry code.
  • Successful access with a Wiegand credential: the CAPXM will pass along the successful credential facility code and ID.

LiftMaster's illustration connects the door board's Data-0, Ground, and Data-1 to a third party access system Wiegand input. This device/reader must be listed to UL 294.

Postal Lock (Page 21)

  1. Remove the wing nut and plug. Discard the wing nut and plug.
  2. Remove 4 mounting nuts from studs.
  3. Install the postal lock using 4 nuts.
  4. Cut the factory installed wire tie from the postal lock switch.
  5. The postal lock switch is wired from the factory.

Source: LiftMaster CAPXM installation manual (English), page 21.

Back to contents

CAPXM Wiring Diagram (Page 22)

LiftMaster's wiring diagram (page 22, not to scale) shows the internal connections on the back of the control board, with wire colors (yellow, white, green, black, white, red, black, red, black, and purple) between these labeled parts: the red Ethernet connection, USB, USB camera, door board, postal lock switch, power supply, Ethernet connection, internal Wi-Fi antenna, optional external Wi-Fi antenna, optional myQ cable extension kit, speaker, microphone, faceplate/screen, display data, and touch panel. LiftMaster states that it is not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes; the information is for suggested use ONLY, and local codes must be checked BEFORE installation. Use the original page 22 for the diagram itself.

Source: LiftMaster CAPXM installation manual (English), page 22.

Back to contents

CAPXM Repair Parts and Accessories

LiftMaster's page 23 lists two tables and the headings "Accessories" and "Repair Parts." The links below open related All Security Equipment category pages and do not by themselves confirm that we stock an item or that it fits your CAPXM.

Repair Parts

Swipe sideways to see all columns.

CAPXM repair parts as printed by LiftMaster (page 23)
Item Part number
Cam and lock kit K41-0215-000
Front panel with display kit, CAPXM K41-0216-000
Control board, CAPXM K41-0217-000
Microphone kit, CAPXM K41-0223-000
Postal lock switch, CAPXM K41-0219-000
Rear housing assembly, CAPXM K41-0220-000
Wiring kit, CAPXM K41-0221-000
Speaker kit, CAPXM K41-0222-000
Power supply kit K41-0227-000
Door board and covers K001D8478
USB camera kit CAPXLCAM

Compatible CAPXM Accessories

Swipe sideways to see all columns.

CAPXM accessories as printed by LiftMaster (page 23)
Item Part number
Reader, multi-class SE RP10 mini mullion LMMC-MINI
Wi-Fi antenna kit K76-38957
Radio antenna kit K76-38958
Radio antenna extension (15 foot) 86LM
Wi-Fi antenna extension (15 foot) WFAEXT
Wi-Fi/Bluetooth external antenna WFBTEXT
ESARM antenna XMANTKIT
Internal proximity reader XMRDRKIT
Wiegand keypad/proximity reader KPR2000*
Connected Access Portal, 2 door CAP2D
Cellular 4G/LTE modem with Wi-Fi CAPCELL
All LiftMaster myQ/UL325 compatible gate operators (listed as an entry; no part number printed) (none printed)
Passport 3-button visor remote control MAX PPV3M
Passport 3-button mini remote control MAX PPK3M
Passport 3-button mini proximity remote control MAX PPK3PHM
Passport Lite 1-button visor remote PPLV1-X**
Passport Lite 1-button key chain remote PPLK1-X**
Passport Lite 1-button mini proximity remote PPLK1PH-X**
RFID long range reader LMSC1000
RFID universal tag (windshield/headlamp) LMUNTG
RFID vehicle hang tag LMHNTG

*The KPR2000 is not UL listed to UL 294. It cannot be used as the primary means of granting or denying access, only for supplemental use. **Available in 10 and 100 packs; replace X with 10 or 100. LiftMaster also notes that a current list of compatible readers and keypads is maintained at LiftMaster.com; if your reader or keypad model is not listed there, contact LiftMaster Technical Support to determine compatibility.

Shop related products: intercom and telephone entry systems | keypads | fob and card readers | remotes and receivers | power supplies | gate operators

Documentation note. In the English text of page 23, the heading "Accessories" appears first and the heading "Repair Parts" after both tables, while the table of contents lists Repair Parts before Accessories. This page assigns the kits for the CAPXM's own components to Repair Parts and the readers, antennas, keypad, remotes, and RFID products to Accessories based on their content. Confirm against page 23 of the original manual.

Source: LiftMaster CAPXM installation manual (English), page 23.

Back to contents

CAPXM Configuration Sheet

LiftMaster provides a configuration sheet (page 24) to record device information and configuration settings. It has fields for the CAPXM name and notes, and, for each of Door 1 and Door 2: the door/gate name; the inputs (Wiegand, REX, status, and whether an EOL resistor is used, yes or no); and the outputs (primary relay and auxiliary relay, each normally open or normally closed). LiftMaster notes that any user of the system is subject to the terms outlined in the product EULA. Print the sheet from the original manual to fill it in.

Source: LiftMaster CAPXM installation manual (English), page 24.

Back to contents

The manual's legal page (page 25) includes the following topics. It is summarized here; read the original page for the full text.

  • Canada, Underwriters Laboratories: the CAPXM shall be installed in accordance with Part 1 of the Canadian Electrical Code.
  • Documentation disclaimer: information in the manual is subject to change without notice and does not represent a commitment on the part of LiftMaster; LiftMaster directs readers to LiftMaster.com for the most up-to-date information. The document and its data shall not be duplicated, used, or disclosed to others for procurement or manufacturing except with LiftMaster's written permission.
  • UL 294 access control unit ratings printed: Endurance: Level 3, Line security: Level 1, Destructive Attack: Level 1, Power Standby: Level 1.
  • FCC and Innovation, Science and Economic Development Canada: the device complies with part 15 of the FCC rules and Canadian license-exempt RSS standards, and is a Class B digital device. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The device must be installed to maintain a minimum 20 cm (8 in.) distance between users or bystanders and the device.
  • ADA: when mounting the CAPXM at a pedestrian entrance, mount the top of the screen no higher than 54 inches from the ground.
  • Local requirements: refer to the local jurisdiction for any specific requirements, such as physical signage that may be required.

Source: LiftMaster CAPXM installation manual (English), page 25.

Back to contents

CAPXM Warranty

Per LiftMaster's warranty (page 26), LiftMaster ("Seller") warrants to the first purchaser of the product, for the structure in which it is originally installed, that it is free from defects in materials and workmanship for a period of two years from the date of purchase. Proper operation depends on complying with the instructions for installation, operation, maintenance, and testing; failure to comply strictly with those instructions will void the limited warranty in its entirety.

If, during the warranty period, the product appears to contain a covered defect, LiftMaster says to call 1-800-528-2806 before dismantling the product, then send it, pre-paid and insured, to its service center for warranty replacement. The warranty does not cover non-defect damage, damage caused by improper installation, operation, or care, labor charges for reinstalling a repaired or replaced unit, problems related to interference, or replacement of batteries, and it limits liability as stated in the full text. The complete terms are printed on page 26 of the manual.

Documentation note. The English warranty gives the number 1-800-528-2806, while the French version of the same manual prints 1 800 528 9131 for the same instruction. Confirm the current warranty phone number with LiftMaster before calling.

All Security Equipment note. If you bought your CAPXM from All Security Equipment, see our refund policy and our Help Center for how manufacturer warranty returns are handled.

Source: LiftMaster CAPXM installation manual (English), page 26.

Back to contents

Frequently Asked Questions About the LiftMaster CAPXM

How many doors or gates can one CAPXM control?

Up to two access points (Door 1 and Door 2 on the door board), each with a primary relay, an auxiliary relay, a Wiegand input, a request-to-exit input, and a status input (page 6). It can also pair wirelessly with up to 4 gate operators, one for each primary and auxiliary relay (page 18). For a single access point, LiftMaster's CAPXS is the smaller model; see Related LiftMaster Resources.

What does the CAPXM need to work?

Per the manual: a myQ Business account with a service subscription (page 11), the supplied 24VDC power supply on a dedicated 120 Vac outlet (page 15), an internet connection by Ethernet or Wi-Fi with at least 5 Mbps upload and download per CAPXM that supports video (page 10), and a SIP account through Phone.com for the calling function (page 11).

How do I enter Admin Mode?

Flip switch #1 on the control board to the ON position (pages 16 and 18). For a new installation, press the login button without entering anything in the Admin Username and Admin Password fields (page 18). See Connect Internet.

What Wi-Fi does the CAPXM support?

802.11b/g/n at 2.4 GHz with WPA3 Personal or WPA2 Personal (AES), up to 250 feet open air. It does not support Wi-Fi extenders, hidden SSIDs, or networks that require secondary authentication such as hotel or airport Wi-Fi. If you cannot get two bars, relocate the router or antenna or use the WFAEXT antenna extension (pages 8, 10, and 16). See Internet Requirements.

Which gate operators can the CAPXM talk to wirelessly?

LiftMaster Security+ 2.0 gate operators, 2018 LiftMaster gate operators (firmware v4.4 and later), and HD operators (firmware v3.3 or later), up to 750 feet open air. It is not compatible with LiftMaster barrier gate operators, and wireless linking needs the optional Passport antenna kit (pages 8 and 18). See Gate Access, Wireless.

How far can I run the power wire?

Up to 300 feet with 14 AWG, 200 feet with 16 AWG, and 100 feet with 18 AWG (page 15). See Connect Power.

What ground does the CAPXM need?

LiftMaster strongly recommends an earth ground rod no more than 12 feet (3.7 m) from the CAPXM, with at least 12 AWG wire (page 14). See Install the Ground.

Which Wiegand formats does the CAPXM accept?

26-bit, 30-bit, 32-bit MiFare, and 37-bit with and without facility code, plus ASCII for keypads; only the 26-bit protocol is compatible in UL installations (pages 6 and 8). The CAPXM also has a 26-bit Wiegand output for third party access systems (page 21).

How high should I mount the CAPXM?

At a pedestrian entrance, to meet ADA compliance, mount the top of the screen no higher than 54 inches from the ground (page 13). See Mount the CAPXM.

Can I power a maglock or door strike from the CAPXM power supply?

No. LiftMaster says not to use the controller's power supply for the maglock, and to use only a UL listed burglar alarm or access control system to power electronic strikes and latches (pages 15, 17, and 19).

What warranty does the CAPXM have?

LiftMaster's limited warranty is two years from the date of purchase. See CAPXM Warranty and page 26 of the manual.

Does the manual come in other languages?

Yes. LiftMaster's combined PDF has the English manual first (pages 1 to 26), followed by French and Spanish versions. This page presents the English version.

Original LiftMaster CAPXM Documentation

This HTML resource is presented by All Security Equipment, is not a LiftMaster publication, and does not replace the original manufacturer documentation. It is based on LiftMaster's CAPXM Smart Video Intercom M installation manual (English).

Check LiftMaster's product page for the current revision before relying on any document, because LiftMaster may update them.

Need the intercom itself? All Security Equipment sells the LiftMaster CAPXM Smart Video Intercom M for residential and commercial applications that control up to two gates or doors.

This resource was last updated November 11, 2026. Based on the LiftMaster CAPXM installation manual (English).