LiftMaster LA500UL Instruction Manual (LA500PKGUL, LA500DC, and LA500DCS)
This page presents the LiftMaster LA500UL light commercial / residential DC vehicular swing gate operator installation manual as searchable, linkable HTML, for the LA500PKGUL single arm package, the LA500DC primary 24 Vdc actuator arm, and the LA500DCS secondary 24 Vdc actuator arm: specifications, safety requirements, installation, wiring, adjustment, programming, troubleshooting, diagnostic codes, maintenance, solar panels, and replacement parts.
Source and scope. This HTML technical resource is based on official LiftMaster documentation for the LA500UL (document 114-6272-000, Rev. A). It is not published by LiftMaster, and All Security Equipment is not the manufacturer. Always verify that the instructions apply to your operator's model and manufacturing date, and follow the original LiftMaster documents when they differ from this page.
Text under "Source: LiftMaster manual" lines follows the manufacturer's documentation. Blue boxes labeled "All Security Equipment note" are our own supplemental guidance and are not manufacturer instructions.
Documentation Information
- Manufacturer
- LiftMaster (The Chamberlain Group, Inc.)
- Models
- LA500PKGUL (single arm package), LA500DC (primary 24 Vdc actuator arm), and LA500DCS (secondary 24 Vdc actuator arm for dual swing gate applications). One manual covers all three.
- Equipment type
- Light commercial / residential DC vehicular swing gate operator (Class I, II, III, and IV)
- Document type
- Installation Manual (English)
- Manufacturer document number
- 114-6272-000
- Manual revision
- Rev. A (printed as 114-6272-000 (Rev. A))
- Manual copyright / publication
- © 2025 The Chamberlain Group LLC. The manual does not print a separate revision date.
- Source
- Official LiftMaster documentation for the LA500UL (see Original LiftMaster Documentation)
- HTML resource last updated
- October 12, 2026
Common tasks: Set the limits | Program a remote | Wiring diagram | Diagnostic codes | Gate will not close | Replace batteries | Replacement parts
LiftMaster LA500UL Manual Overview
The LiftMaster LA500UL is a light commercial / residential DC vehicular swing gate operator. LiftMaster's installation manual (document 114-6272-000 Rev. A) covers the LA500PKGUL single arm package, the LA500DC primary 24 Vdc actuator arm for single swing gate applications, and the LA500DCS secondary 24 Vdc actuator arm for dual swing gate applications. LiftMaster states that external safety devices are required (see the UL 325 entrapment protection requirements), that the operator must be installed and serviced by a trained gate systems technician only, that it is for use on vehicular passage gates only, and that it is intended for Class I, II, III, and IV vehicular swing gate applications. It is compatible with myQ and Security+ 2.0 accessories and Security+ 3.0 MAX and Universal accessories.
What Is in the LA500UL Carton
LiftMaster's carton inventory (page 6) shows the vehicular swing gate operator, a standard control box with two 12 Vdc 7AH batteries, a post bracket and gate bracket, two warning signs and the warranty card, two keys, the installation manual, and a LiftMaster monitored retro-reflective photoelectric sensor. For the LA500DCS (secondary arm) only, the carton adds a post bracket, two keys, a gate bracket, a junction box, a terminal block connector, a watertight connector, and an extension cable. Not shown: documentation packet and hardware bag.
Optional accessories (LiftMaster, page 6): large metal control box (Model LA500CONTXLMUL), ideal for installations that require additional room in the control box (batteries not included); and the large metal control box for solar applications (Model XLSOLARCONTUL), required for solar installations (batteries not included), which requires two 33AH batteries, a battery tray, and a solar battery harness. See Accessories.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 6.
LiftMaster LA500UL Specifications
LA500UL operator specifications as printed by LiftMaster (page 7)
Swipe sideways to see all columns.
| Specification | LA500UL |
|---|---|
| Usage classification | Class I, II, III, and IV |
| Main AC supply | 120 Vac, 2 Amps (8 Amps including accessory outlets) OR 240 Vac, 1 Amp |
| System operating voltage | 24 Vdc transformer run / battery backup |
| Accessory power | 24 Vdc, 500 mA max. for ON + SW (switched) |
| Solar power max | 24 Vdc at 60 watts max. |
| Maximum gate weight / length | 1600 lbs. (725.7 kg) / 8 ft (2.4 m); 800 lbs. (362.9 kg) / 16 ft (4.9 m); 600 lbs. (272.2 kg) / 18 ft (5.5 m) |
| 90 degree travel time* | 15-18 seconds |
| Maximum travel range* | 115 degrees |
| Maximum daily cycle rate | 300 cycles / day |
| Maximum duty cycle | Continuous |
| Operating temperature | -40°C to 60°C (-40°F to 140°F) |
| Expansion board | Provided |
| External entrapment protection device inputs (noncontact and/or contact) | Main board: up to 2 close entrapment protection devices and 1 open entrapment protection device. Expansion board: up to 3 entrapment protection devices configurable to either close or open direction and up to 8 edge sensors using wireless edge sensor kit models LMWEKITU and LMWETXU. |
*Travel time and range are affected by the A and B mounting dimensions (see Position the Brackets).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 7.
Important Safety Information
This section reproduces the safety requirements that LiftMaster places at the front of the LA500UL manual (pages 1 to 5). Safety text is kept close to the manufacturer's wording on purpose.
Who Should Install and Service the LA500UL
- THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
- EXTERNAL SAFETY DEVICES REQUIRED. See the UL 325 entrapment protection requirements below.
- This model is for use on vehicular passage gates ONLY and is not intended for use on pedestrian passage gates.
- This model is intended for use in Class I, II, III, and IV vehicular swing gate applications.
LiftMaster's manual also includes a Safety Symbol and Signal Word Review on page 2. See the original manual for the symbols and signal words LiftMaster uses.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 1.
Gate Operator Usage Classes
LiftMaster's manual defines four vehicular gate operator usage classes (page 3). The LA500UL is intended for all four classes.
- Class I, Residential Vehicular Gate Operator: a vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one to four single families.
- Class II, Commercial/General Access Vehicular Gate: a vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public.
- Class III, Industrial/Limited Access Vehicular Gate: a vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.
- Class IV, Restricted Access Vehicular Gate Operator: a vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 3.
UL 325 Entrapment Protection Requirements for the LA500UL
- A minimum of two independent* monitored entrapment protection devices are required to be installed at each entrapment zone.
- Every installation is unique. It is the responsibility of the installer to install external monitored entrapment protection devices in each entrapment zone.
- The operator will only operate with a minimum of two independent monitored entrapment protection devices installed in either the open or closed direction. If no entrapment zone exists in the other direction, an external entrapment protection device is NOT required in that direction.
- Use the Site Planning Safety Checklist in the Appendix to identify entrapment zones found in your installation.
- Acceptable entrapment protection device types include inherent (built into the operator), LiftMaster monitored external photoelectric sensors, and LiftMaster monitored external edge sensors (see Accessories).
- This operator has an inherent entrapment protection device built in. The installer MUST provide one additional entrapment protection device for each entrapment zone.
* INDEPENDENT MONITORED ENTRAPMENT PROTECTION DEVICE: an entrapment protection device is independent if it is a different type (photoelectric sensors, edge device, inherent protection device) from the other devices in the same entrapment zone.
IMPORTANT SAFETY INSTRUCTIONS. To reduce the risk of INJURY or DEATH:
- READ AND FOLLOW ALL INSTRUCTIONS.
- NEVER let children operate or play with gate controls. Keep the remote control away from children.
- ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
- Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the speed, force, or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.
- Use the manual release ONLY when the gate is not moving.
- KEEP GATES PROPERLY MAINTAINED. Read this manual. Have a Trained Gate Systems Technician make repairs to gate hardware.
- The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
- SAVE THESE INSTRUCTIONS.
All Security Equipment note. The manual's safety instructions on page 3 say "emergency release," while the maintenance instructions on page 33 and the operation section on page 29 say "manual disconnect release" and "manual release." They describe the same release lever.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 3.
Safety Installation Information
- Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.
- Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards.
- A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include edge sensors (contact), photoelectric sensors, and instructional and precautionary signage.
- Install the gate operator only when, among LiftMaster's conditions, the operator is appropriate for the construction and the usage class of the gate and all exposed pinch points are eliminated or guarded.
- The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
- The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
- The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. (Per LiftMaster, one or more contact sensors shall be located on the bottom edge of a swing gate when the bottom edge is greater than 4 inches (10.1 cm) but less than 16 inches (406 mm) above the ground at any point in its arc of travel; see item 12.)
- Permanently mounted access controls intended for users to activate must be located at least 6 feet (1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. Exception: emergency access controls only accessible by authorized personnel (e.g. fire, police) may be placed at any location in the line-of-sight of the gate.
- The Stop and/or Reset (if provided separately) must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
- A minimum of two (2) WARNING SIGNS shall be installed in the area of the gate. Each placard is to be visible by persons located on the side of the gate on which the placard is installed.
- For a gate operator utilizing a non-contact sensor: (a) reference the owner's manual regarding placement of non-contact sensors for each type of application (see Install Entrapment Protection); (b) care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving; (c) one or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
- For a gate operator utilizing a contact sensor such as an edge sensor: (a) one or more contact sensors shall be located where the risk of entrapment or obstruction exists; (b) a hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage; (c) a wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals is not obstructed or impeded by building structures, natural landscaping or similar obstruction, and shall function under the intended end-use conditions; (d) one or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 4 inches (10.1 cm) but less than 16 inches (406 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 4.
Gate Construction Requirements (ASTM F2200)
LiftMaster states that vehicular gates should be installed in accordance with ASTM F2200, Standard Specification for Automated Vehicular Gate Construction (contact ASTM at 610-832-9585 or www.astm.org for a copy). The manual lists these provisions (page 5):
General requirements
- 1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed; refer to ASTM F2200 for additional gate types.
- 1.2 Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detached from the supporting hardware.
- 1.3 Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (12.7 mm) when other than the exceptions listed in ASTM F2200.
- 1.4 The minimum height for barbed tape shall not be less than 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade.
- 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator.
- 1.6 A gate latch shall not be installed on an automatically operated gate.
- 1.7 Protrusions shall not be permitted on any gate; refer to ASTM F2200 for exceptions.
- 1.8 Gates shall be designed, constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected. For a vehicular horizontal swing gate (1.8.1), this shall not result in continuous, unimpeded movement in either direction along the arc of its path of travel.
- 1.9 For pedestrian access in the vicinity of an automated vehicular gate, a separate pedestrian gate shall be provided. The pedestrian gate shall be installed in a location such that a pedestrian shall not come in contact with a moving vehicular access gate. A pedestrian gate shall not be incorporated into an automated vehicular gate panel.
Specific applications
- 2.1 Any non-automated gate that is to be automated shall be upgraded to conform to the provisions of this specification.
- 2.2 This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated.
- 2.3 When the gate operator requires replacement, the existing gate shall be upgraded to conform to the provisions of this specification.
- 2.4 When the gate of an automated gate system requires replacement, the new gate shall conform to the provisions of this specification.
Vehicular horizontal swing gates
- 3.1 The following provisions apply to Class I, Class II and Class III vehicular horizontal swing gates. 3.1.1 Gates shall be designed, constructed and installed so as not to create an entrapment area between the gate and the supporting structure or other fixed object when the gate moves toward the fully open position, subject to 3.1.1.1 and 3.1.1.2.
- 3.1.1.1 The width of an object (such as a wall, pillar or column) covered by a swing gate when in the open position shall not exceed 4 inches (102 mm), measured from the center line of the pivot point of the gate. Exception: for a gate not in compliance with this provision, the defined area must be provided with entrapment protection per UL 325.
- 3.1.1.2 Except for the zone specified in Section 3.1.1.1, the distance between a fixed object such as a wall, pillar or column, and a swing gate when in the open position shall not be less than 16 inches (406 mm). Exception: for a gate not in compliance with this provision, the defined area must be provided with entrapment protection per UL 325.
- 3.2 Class IV vehicular horizontal swing gates shall be designed, constructed and installed in accordance with security related parameters specific to the application in question.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 5.
Role of Dealers, Installers, and Trained Gate System Technicians
LiftMaster's list for dealers, installers, and trained gate system technicians (page 5) includes these items:
- Demonstrate the basic functions and safety features of the gate system to owners/end users/general contractors, including how to turn off power and how to use the manual release.
- Leave safety instructions, product literature, installation manual and maintenance manual with the end user.
- Explain to the owners the importance of testing by a trained gate system technician that includes a routine re-testing of the entire gate system.
Role of End Users and Home Owners
- Contact a trained gate systems technician to maintain and repair the gate system (end users should never attempt to repair the gate system).
- Retain and utilize the installation manual and maintenance and important safety instructions.
- Routinely check all gate operator functions and gate movement.
- Discontinue use if safety systems operate improperly, the gate is damaged, or the gate is difficult to move.
- Contact a trained gate systems technician to repair the gate system.
- Prominently display and maintain warning signs on both sides of the gate.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 5.
LiftMaster LA500UL Installation
LiftMaster presents LA500UL installation as eleven steps, followed by limit and force adjustment and an obstruction test. Each step below is labeled with the matching LiftMaster step number.
- Step 1, Position the brackets
- Step 2, Attach the brackets
- Step 3, Install the control box
- Step 4, Earth ground rod
- Step 5, Wire the operator arm to the control board
- Step 6, Dual gate setup
- Step 7, Install entrapment protection
- Step 8, Wire entrapment protection devices
- Step 9, Power wiring
- Step 10, Install warning signs
- Step 11, Finish the installation
After Step 11, continue with limit and force adjustment and the obstruction test. Solar installations also use Solar Panels in the appendix.
Installation Requirements and Tips
- To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep.
- ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
LiftMaster's do's:
- Weld a horizontal bar across the entire gate on any installation for strength. Make sure that the operator is mounted level or it will not function properly.
- The operator can be mounted on top of the gate frame.
- The operator must be installed at least 12 inches (30 cm) from the ground.
- Make sure there is slack in the operator cable.
LiftMaster's don'ts:
- DO NOT install upside down.
- DO NOT install on ANY pedestrian passageways, doorways, or gates.
- DO NOT install next to sprinklers or any area that may expose the bottom of the operator to water.
- DO NOT over-bend the operator cable. Doing this will cause the wires to eventually break.
- DO NOT install on uphill or downhill gates.
- DO NOT weld the crossbar on just a few pickets, or they could bend.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 9.
Site Preparation
- Check the national and local building codes BEFORE installation.
- Trench: trench and install conduit. Before trenching, contact underground utility locating companies. Conduit must be UL approved for low and high voltage.
- Safety: entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application. Install a warning sign (two provided) on the inside and outside of the property, where easily visible.
- Gate: the gate must be constructed and installed according to ASTM F2200 standards (see Gate Construction Requirements), and must fit the specifications of the operator (see Specifications).
- Additional accessories: vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. They are suggested for vehicles 14 feet (4.27 m) or longer and are not required but are recommended. Before installing your access control device(s), complete a site survey and determine the best device for your site needs.
Refer also to the Site Planning Safety Checklist in the Appendix.
Check your gate (LiftMaster): the gate MUST be level. The gate and gate post MUST be plumb. The gate MUST have a smooth bottom edge, and no protrusions should exist. Remove ANY/ALL wheels from the bottom of the gate. The gate MUST NOT hit or drag across the ground. The gate MUST swing freely and be supported entirely by its hinges.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 8.
Position the Brackets (Step 1)
If this operator is a replacement for a Miracle-One operator, use the existing post bracket and gate bracket: remove the Miracle-One operator from the brackets and proceed to the next step. LiftMaster notes that the measurements in its drawings are typical for a standard installation and that your installation may be different. The gate bracket MUST be installed in an area that can withstand heavy forces; additional reinforcement steel plates may be necessary for mounting. If your application is push-to-open, see the illustrations in the Appendix (page 48).
Step 1, position the brackets
- Choose a vertical mounting location for the post bracket.
- Close the gate.
- Place a measuring tape under the center of the gate hinge point and measure out dimension A (see the chart).
- Use a screwdriver or dowel rod to temporarily mark the location of the first measurement.
- Measure out dimension B (see the chart) from the previous mark.
- Use a screwdriver to mark the location of the second measurement.
- Align the post bracket as close as possible above the screwdriver or dowel rod and tack weld the post bracket in the desired vertical position.
- Position a level on the post bracket and measure 35-1/2 inches (90.2 cm) over from the center hole of the post bracket and mark the location on the gate. Measure 2-1/4 inches (6.4 cm) down from the previous mark and center the gate bracket on this mark. Tack weld the gate bracket in this position.
There should only be a maximum of 4 inches (10.2 cm) from the center of the hinge to the edge of the post or column. While the gate is in the fully open position, the operator needs a clearance of 11-1/4 inches (28.6 cm) minimum. The ideal installation measurements are A = 7-3/4 inches (19.7 cm) and B = 8-1/2 inches (21.6 cm); see the A and B dimension chart on page 10 for the other combinations.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 10.
Attach the Brackets (Step 2)
Step 2, attach the brackets
- Insert the key into the lock and turn it 180 degrees counterclockwise.
- Turn the release lever 180 degrees counterclockwise. The operator is now in manual mode.
- Position the operator on the brackets and make sure the operator is level and positioned correctly on the gate.
- Remove the operator from the gate.
- Completely weld around the post bracket and gate bracket. Brackets may need additional reinforcement by welding flat stock.
- Attach the operator to the post bracket with the bolt, mounting plate, and nut. Attach the gate bracket to the operator with the bolt, washer, and nut. Tighten the nut until it reaches the bottom of the gate bracket, then turn the nut a half turn, making sure not to overtighten.
- Make sure the trolley does not reach the fully open or fully closed position. Extra force may be needed to move the trolley back and forth.
For dual gate applications, repeat the previous installation steps to install the second operator.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 11.
Install the Control Box (Step 3)
The control box MUST be mounted within 5 feet (1.52 m) of the gate operator. Mount the control box as high as possible for best radio reception. Make sure the control box is level.
Standard control box
The expansion board does not need to be removed for a wall or column mount installation.
- Remove the screws and open the control box.
- For a post mount, remove the expansion board by removing the screws, and disconnect the "Main Board" connector from the expansion board.
- Select the mounting holes (according to your application) and remove the knockouts using a screwdriver and hammer.
- Secure the control box to the mounting surface. Wall or column: use the provided screws (4). Post: use U-bolts and rubber washers (not provided) to ensure a watertight seal. Make sure the U-bolts do not protrude more than 3/4 inch from the control box because this can short the control board.
- Reinstall the expansion board and connect the "Main Board" connector to the expansion board.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 12.
Large metal control box (LA500CONTXLMUL; solar model XLSOLARCONTUL)
The Large Metal Solar Control Box (Model XLSOLARCONTUL) does not have the electrical outlets or the expansion board shown in LiftMaster's images.
Wall or column mount:
- Open the control box. The control box door may be removed by opening the door 90°. Lift the door from the hinges and set aside until the installation is complete.
- Remove the toroid assembly from the control box by loosening the three screws and lifting the assembly up and out.
- Use the knock outs located at the 4 corners of the control box and knock out using a screwdriver and hammer.
- Secure the control box to the mounting surface using the provided screws (4).
Post mount: the post mount option is not recommended for the 33AH battery application.
- Open the control box. The control box door may be removed by opening the door 90°. Lift the door from the hinges and set aside until the installation is complete.
- The control box can be mounted to a post with 'U' bolts (see the chart on page 13 of the manual). The knock out will accommodate a 3/8 inch diameter 'U' bolt. Select the center mounting holes (top and bottom) and knock out using a screwdriver and hammer.
- Secure the control box to the mounting surface with U-bolts and rubber washers (not provided) to ensure a watertight seal.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 13.
Earth Ground Rod (Step 4)
- ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
- Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity.
- ALL electrical connections MUST be made by a qualified individual.
- DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram.
Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
- Install the earth ground rod within 3 feet (.9 m) of the operator.
- Run wire from the earth ground rod to the control box. The earth ground wire will be connected later (see Step 9, Power Wiring).
LiftMaster notes that if the operator is not grounded properly the range of the remote controls will be reduced and the operator will be more susceptible to lightning and surge damage.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 14.
Wire the Operator Arm to the Control Board (Step 5)
Step 7, wire the operator arm
- Choose a knockout in the bottom of the control box.
- Insert the operator cable through the provided watertight connector.
- Insert the operator cable and watertight connector into the knockout.
- Slide the connector nut onto the operator cable.
- Connect the operator cable wires to the connector according to the colored label on the connector (white to white, red to red, etc.).
- Plug the connector into the GATE 1 terminal on the control board as shown.
- Tighten the connector nut.
If installing one operator, proceed to Step 7. If installing two operators, continue with Step 6.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 14.
Dual Gate Setup (Step 6)
There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications. Wireless dual gates will require the installation of two control boxes, one for each operator arm.
Wireless setup: activate the wireless feature
Install a second operator arm and control box by following installation steps 1 to 5.
- Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. LiftMaster recommends that all accessories and board configurations are set on the primary operator.
- Press and release the LEARN button on the primary operator. The green XMITTER LED will light. The operator will time out of programming mode after 180 seconds.
- Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light.
- Press and release the OPEN test button to assign this operator as network primary.
- Press and release the LEARN button on the second operator. The green XMITTER LED will light.
- Press and release the LEARN button again on the second operator. The yellow NETWORK LED will light.
- Press and release the CLOSE test button to assign this operator as network second. Both operators will beep and the yellow NETWORK LEDs will turn off, indicating programming is successful.
Wireless setup: deactivate the wireless feature
- Press and release the LEARN button on either operator. The green XMITTER LED will light.
- Press and release the LEARN button again on the same operator. The yellow NETWORK LED will light.
- Press and hold the LEARN button for 5 seconds. The yellow NETWORK LED will blink (operator will beep) then turn off, indicating successful deactivation.
- Repeat the steps for the other operator.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 15.
Wired setup: install the second arm, extension cable and junction box
Install a second operator arm by following installation steps 1 and 2. Before digging, contact local underground utility locating companies.
- Trench across the driveway to bury the extension cable. Use PVC conduit to prevent damage to cables.
- Open the junction box by removing screws (4) and set aside.
- Select the holes to be used for mounting and knock out using a screwdriver and hammer. Drill two holes in the junction box large enough for the watertight connectors.
- Mount the junction box within 3 feet (0.9 m) of the second operator.
- Route the operator cable and extension cable through the watertight connector nut and watertight connector.
- Insert the cables and watertight connectors into the holes in the junction box.
- Slide the connector nut onto the operator cable and extension cable.
- Connect the wires from the extension cable and operator cable to the terminal block connector (like-colored wires must face each other: brown, green, white, yellow, blue, red).
- Put the wires inside of the junction box.
- Secure the operator and extension cables by tightening the connector nut.
- Reinstall the cover.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 16.
Wired setup: wire the secondary operator arm to the control board
- Choose a knockout in the bottom of the control box.
- Insert the extension cable through the watertight connector.
- Insert the extension cable and watertight connector into the knockout.
- Slide the connector nut onto the operator cable.
- Connect the extension cable wires to the connector according to the colored label on the connector (white to white, red to red, etc.).
- Plug the connector into the GATE 2 terminal on the control board as shown.
- Tighten the connector nut.
Set the bipart delay
Single control box. Occasionally in dual gate installations, one gate will need to open first and close second. This would happen if there was an ornamental overhang on one gate or if using a solenoid lock, for example. This gate is called the primary gate and needs to be connected to the Gate 1 connections on the control board. Thus, it is preferred that the control box be installed on the same side as this gate. If there is no appropriate location on that side for the control box, then mount the control box on the opposite side, but connect the operator closest to the control box to the Gate 2 connector and the operator on the opposite side to the Gate 1 connector. The BIPART DELAY switch on the control board needs to be set to the ON position.
Dual control boxes. The BIPART DELAY switch is used with dual control box applications and serves two functions. BIPART DELAY: used in applications where a maglock, solenoid lock, or decorative overlay would require one gate to close before the other; the control box with the BIPART DELAY switch ON will delay from the close limit when opening and be the first to close from the open limit. SYNCHRONIZED CLOSE: also used in applications where one gate travels a longer distance than the other; to synchronize the closing of the gates, set the BIPART DELAY switch to ON for both control boxes.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 17.
Install Entrapment Protection (Step 7)
To prevent SERIOUS INJURY or DEATH from a moving gate:
- ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone.
- Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
- Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
- Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts, walls, pillars, columns, or operator itself.
Install entrapment protection devices according to the UL 325 Entrapment Protection Requirements. LiftMaster's instructions:
- Use the Site Planning Safety Checklist in the Appendix to identify entrapment zones that will result from the installation.
- Install entrapment protection devices for ALL entrapment zones.
- This operator has an inherent entrapment protection device built in. The installer MUST provide one additional entrapment protection device for each entrapment zone.
- The operator will NOT run unless a minimum of one external device is connected in either the open or closed direction.
- LiftMaster monitored external entrapment protection devices MUST be used with LiftMaster operators to meet UL 325 requirements, see Accessories.
- Test ALL entrapment protection devices after completing installation of the operator. For testing instructions, refer to the manual provided with your entrapment protection device.
LiftMaster's illustrations (credited to the DASMA Gate Systems Safety Guide) show example sites and note that your site may have additional entrapment zones which MUST be protected. Mount access control devices at least 6 feet (1.8 m) beyond the gate. Place the warning signs on both sides of the gate in clear view, and make sure a separate pedestrian entrance is available and the path is clearly designated. See the original manual (page 18).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 18.
Wire Entrapment Protection Devices (Step 8)
LiftMaster describes three options for wiring external devices, depending on the device and how it will function. Refer to the manual included with your entrapment protection device. The inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored entrapment protection device may be wired to each input. Additional devices may be wired to the expansion board. Board inputs for entrapment protection devices are yellow.
LA500UL entrapment protection inputs
Swipe sideways to see all columns.
| Board and input | Device | Behavior when an obstruction is sensed (LiftMaster) |
|---|---|---|
| Control board: CLOSE EYES/INTERRUPT (2 terminals) | Close direction photoelectric sensor | During gate closing the gate will open to the full open position and resets the Timer-to-Close. The input is disregarded during gate opening. |
| Control board: CLOSE EDGE (2 terminals) | Close direction edge sensor | During gate closing the gate will reverse to the full open position, disengaging the Timer-to-Close. The input is disregarded during gate opening. |
| Control board: OPEN EYES/EDGE (2 terminals) | Open direction photoelectric sensor or edge sensor | During gate opening the gate will reverse for 4 seconds then stop. The input is disregarded during gate closing. |
| Expansion board: EYE ONLY and COM | Open or close direction photoelectric sensors | Based on the switch next to the terminals. Switch set to CLOSE: gate reverses fully. Switch set to OPEN: gate reverses 4 seconds. |
| Expansion board: EYE/EDGE and COM (two inputs) | Open or close direction photoelectric sensors or edge sensor | Based on the switch next to the terminals. Switch set to CLOSE: gate reverses fully. Switch set to OPEN: gate reverses 4 seconds. |
Source: LiftMaster manual, 114-6272-000 Rev. A, page 19.
Power Wiring (Step 9)
The standard control box can be wired for either 120 Vac or 240 Vac; the factory default is 120 Vac. The large metal control box (XLM) can be wired for 120 Vac (default). The batteries are charged in the circuit by the toroid transformer, plug-in transformer, or the solar panels. Main power supply and control wiring MUST be run in separate conduits. For solar applications refer to Solar Panels in the appendix. If using an external receiver, use shielded wire for the connections and mount the receiver away from the operator to avoid interference from the operator.
LA500UL maximum wire length by operator power source
Swipe sideways to see all columns.
| Wire gauge (AWG) | 120 VAC | 240 VAC |
|---|---|---|
| 14 | 350 feet (107 m) | 1,150 feet (351 m) |
| 12 | 525 feet (160 m) | 1,850 feet (564 m) |
| 10 | 850 feet (259 m) | 2,950 feet (899 m) |
Use copper conductors ONLY. All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
Standard control box
- Turn off the AC power from the main power source circuit breaker.
- Run the AC power wires to the control box.
- Remove the toroid assembly from the control box by loosening the four screws and lifting the assembly up and out.
- Ensure the 120/240 plug is connected to either the 120 or 240 Vac connector on the EMI board depending on your application. The factory default is 120 Vac.
- Connect the ground wire to the ground screw on the back of the toroid assembly.
- Connect the white wire from the toroid assembly to NEUTRAL using a wire nut.
- Connect the black wire from the toroid assembly to HOT using a wire nut.
- Replace the toroid assembly and tighten the four screws. Ensure the wires are not pinched.
- Plug the J15 plug into the control board. The control board will power up. You may see a small spark when plugging the J15 plug into the board.
- Turn ON AC power to the operator.
Large metal control box (LA500CONTXLMUL)
To use solar panels with the large metal control box (Model XLSOLARCONTUL), skip these steps and refer to Solar Panels in the appendix.
- Unplug the J15 plug labeled BATT(-)(+) DC(-)(+) on the control board by squeezing the plug and pulling it from the control board.
- Turn off the AC power from the main power source circuit breaker.
- Run the AC power wires to the control box.
- Remove the toroid assembly from the control box by loosening the three screws and lifting the assembly up and out.
- Ensure the 120/240 plug is connected to either the 120 or 240 Vac connector on the EMI board depending on your application. The factory default is 120 Vac.
- Connect the ground wire to the ground screw on the back of the toroid assembly.
- Connect the white wire from the toroid assembly to NEUTRAL using a wire nut.
- Connect the black wire from the toroid assembly to HOT using a wire nut.
- Replace the toroid assembly and tighten the screws. Ensure the wires are not pinched.
- Connect a jumper between the positive (+) terminal of one battery to the negative (-) terminal of the other battery.
- Connect the red wire from the J15 plug labeled BATT (+) to the positive (+) terminal of the battery.
- Connect the black wire from the J15 plug labeled BATT (-) to the negative (-) terminal of the battery.
- Plug the J15 plug into the control board. The control board will power up. You may see a small spark when plugging the J15 plug into the board.
- Turn ON AC power.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 20 to 21.
Install Warning Signs (Step 10)
Installers MUST install the UL required warning signs. The signs MUST be installed in plain view on both sides of each gate installed. Use the fastening holes in each corner to permanently secure the sign.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 22.
Finish the Installation (Step 11)
Step 11, finish the installation
- Turn the release lever clockwise 180° back to the engaged position. This engages the motor.
- Turn the key clockwise 180°. This locks the release lever. The operator is now engaged.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 22.
LiftMaster LA500UL Wiring
LiftMaster LA500UL Wiring Diagram
LiftMaster's installation manual shows the standard control box wiring diagram on page 59 and the large metal control box wiring diagram on page 60 (document 114-6272-000 Rev. A). This page does not reproduce the diagram; use the original LiftMaster manual for terminal-level connections. See Original LiftMaster Documentation.
- To protect against fire and electrocution: DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator.
- For continued protection against fire: replace ONLY with a fuse of the same type and rating.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 59 to 60.
Wiring Accessories to the LA500UL Control Board
All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. LiftMaster describes these control board inputs and outputs (pages 34 and 35):
LA500UL control board inputs and outputs
Swipe sideways to see all columns.
| Input / output | Terminals | Function (LiftMaster) | Manual page |
|---|---|---|---|
| EXIT | 2 terminals | Soft open command (maintained switch does not override external safeties and does not reset alarm condition). Used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open. Opens a closing gate and holds open an open gate; if maintained, pauses Timer-to-Close at OPEN limit. | 34 |
| SHADOW | 2 terminals | Used for an external shadow loop detector when the loop is positioned under the swing of the gate. Holds open gate at open limit; only active when the gate is at the OPEN limit, disregarded at all other times; pauses Timer-to-Close at OPEN limit. | 34 |
| INTERRUPT | 2 terminals | Used for photoelectric sensors and an external interrupt loop detector when the loop is on the outside of the gate. Holds open gate at open limit; stops and reverses a closing gate to open limit; pauses Timer-to-Close at OPEN limit; activates quick close and anti-tailgate features when enabled on the expansion board. | 34 |
| Maglock (LOCK) | 2 terminals, N.C. and COM | Relay contact output, normally closed (N.C.) output for maglocks. The relay activates prior to motor activation and during motor run. The relay is off when the motor is off. | 35 |
| Single button control (SBC) | 2 terminals | Gate command sequence: open, stop, close, stop, and so on. Soft open (maintained switch does not override external safeties and does not reset alarm condition). | 35 |
| Fire department open input | 2 terminals | Acts as a hard open. A maintained input overrides (ignores) external safeties (photoelectric sensor and edge) and pauses Timer-to-Close. A momentary input logic works as single button control, safeties remain active, and Timer-to-Close is re-enabled. | 35 |
| Accessory power, 24 VDC, MAX 500 mA | 4 terminals | SWITCHED: switched ON with gate motion and at the open limit when Timer-to-Close is active; turns off 5 seconds after motion. UNSWITCHED: 24 Vdc voltage out to power accessories, always ON. | 35 |
Entrapment protection devices are wired as described in Wiring entrapment protection devices (page 21). The expansion board provided with the LA500UL adds inputs for additional entrapment protection devices and controls; see Expansion Board and Accessory Connections.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 34 to 35.
Expansion Board and Accessory Connections
To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.
Expansion board switches
- EXIT FAIL switch. OPEN: if the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, then the gate will open and remain open until the fault is cleared. CLOSE: if the EXIT plug-in loop detector detects a fault, faults are ignored (EXIT loop is faulted and inoperative).
- AC FAIL switch. OPEN: loss of AC power will cause the gate to open approximately 15 seconds after AC power fail and remain OPEN until AC power is restored (enabling the Timer-to-Close). BATT: with loss of AC power, the gate will remain in its present position and the operator is powered from the batteries.
- ANTI TAIL switch. OFF: when the CLOSE EYES/Interrupt loop is activated it causes a closing gate to stop and reverse. ON: when the CLOSE EYES/Interrupt loop is activated it causes a closing gate to pause; once the vehicle is clear the gate will continue to close.
- QUICK CLOSE switch. OFF: no change to the gate's normal operation. ON: when the CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped gate to close (ignores the Timer-to-Close).
- AUX RELAY switches. Set the AUX RELAY switches as needed to obtain the desired function as shown in the auxiliary relay table below.
- EYE/EDGE switches. Set the EYE/EDGE switches as needed to obtain the desired OPEN or CLOSE functionality.
- 1, 2, and 3 LEDs. LEDs indicating the status of the EYE/EDGE inputs. They are also used to check the firmware version of the expansion board.
- MAIN BOARD input, input LEDs, loop detector inputs, and wireless edge input. The main board input is the connection for the main board connector; the input LEDs indicate the status of the SBC, OPN, CLS, and STP inputs; the loop detector inputs are for the plug-in loop detectors (Model LOOPDETLM); and the wireless edge input is for the wireless edge kit (Model LMWEKITU).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 36.
Auxiliary relays 1 and 2
The auxiliary relays provide Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only. The function of the relay contact activation is determined by the switch settings.
LA500UL auxiliary relay 1 and 2 switch settings (relay contacts: Class 2 low voltage only, 42 Vdc [34 Vac] max, 5 Amps)
Swipe sideways to see all columns.
| Aux relay setting | Switch 1 | Switch 2 | Switch 3 | Aux relay 1 (LiftMaster) | Aux relay 2 (LiftMaster) |
|---|---|---|---|---|---|
| Off (no feature selected) | OFF | OFF | OFF | Relay always off Use this Aux Relay setting to conserve battery power. | Same function as aux relay 1 (one cell spans both relays in the manual) |
| Open Limit Switch | OFF | OFF | ON | Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate). | Same function as aux relay 1 (one cell spans both relays in the manual) |
| Close Limit Switch | OFF | ON | OFF | Energizes when not at close limit. For an additional audible or visual display, connect an external light (low voltage). | Same function as aux relay 1 (one cell spans both relays in the manual) |
| Gate Motion | OFF | ON | ON | Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an external buzzer or light (low voltage). | Same function as aux relay 1 (one cell spans both relays in the manual) |
| Pre-Motion Delay | ON | OFF | OFF | Energizes 3 seconds before gate motion and remains energized during gate motion. The onboard alarm will sound. For an additional audible or visual display, connect an external buzzer or light (low voltage). | Energizes 3 seconds before gate motion and remains energized during gate motion. For an additional audible or visual display, connect an external buzzer or light (low voltage). |
| Power | ON | ON | OFF | Energizes when AC power or solar power is present. There is approximately a 10-12 second delay before relay cutoff after AC shutdown. | Energizes when on battery power. There is approximately a 10-12 second delay before relay cutoff after AC shutdown. |
| Tamper | ON | OFF | ON | Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible or visual display, connect an external buzzer or light (low voltage). | Same function as aux relay 1 (one cell spans both relays in the manual) |
| Cycle Quantity Feedback | ON | ON | ON | The 1, 2, and 3 LEDs will blink out the cycle count (cycle count is stored on the control board). See below. | Not used. |
Cycle count (LiftMaster): first, note the current Aux Relay switch positions. To determine the actual cycles that the gate operator has run (in thousands), set all three Aux Relay switches to the ON setting for Aux Relay 1. The expansion board's 1, 2, and 3 LEDs will blink out the cycle count, with the 1 LED blinking 1000's, the 2 LED blinking 10,000's, the 3 LED blinking 100,000's, and all three LEDs blinking together for 1,000,000's (example: the 1 LED blinks 3 times, the 2 LED blinks 6 times, and the 3 LED blinks once; the cycle count is 163,000). The cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set the Aux Relay switches back to their appropriate positions. The cycle count cannot be reset or changed. If under 1,000 cycles the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off. The expansion board will flash the cycle count 3 times, then all the LEDs will turn on solid for 10 seconds, then turn off.
The manual also contains a red/green light functionality table (red light wired to Aux Relay 1, green light to Aux Relay 2) on page 37.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 37.
Wiring accessories to the expansion board
LA500UL expansion board inputs
Swipe sideways to see all columns.
| Input | Terminals | Function (LiftMaster) |
|---|---|---|
| Entrapment protection (eye only) | EYE ONLY and COM | Open or close direction photoelectric sensors; the functionality is based on the switch settings next to the terminals. Switch set to CLOSE: gate reverses fully when an obstruction is sensed. Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed. |
| Entrapment protection (eye or edge) | EYE/EDGE and COM (two inputs) | Open or close direction photoelectric sensors or edge sensor; the functionality is based on the switch settings next to the terminals. Switch set to CLOSE: gate reverses fully. Switch set to OPEN: gate reverses 4 seconds. |
| Single button control | SBC and COM | Gate command sequence: open, stop, close, stop, and so on. |
| Open | OPEN and COM | Open command, soft open (maintained switch does not override external safeties and does not reset alarm condition). If maintained, pauses Timer-to-Close at OPEN limit. Opens a closing gate and holds open an open gate. |
| Close | CLOSE and COM | Close command, soft close (maintained switch does not override external safeties and does not reset alarm condition). |
| Stop | STOP and COM | Stop command, stops a moving gate. If maintained, pauses Timer-to-Close at OPEN limit. Overrides an Open or Close command. |
| EXIT loop | EXIT | Loop wire connection for a plug-in loop detector when the loop is inside the secured area near the gate. Open command, soft open; if maintained, pauses Timer-to-Close at OPEN limit; opens a closing gate and holds open an open gate. |
| SHADOW loop | SHADOW | Loop wire connection for a plug-in loop detector when the loop is positioned under the gate. Holds open gate at open limit; disregarded during gate motion; pauses Timer-to-Close at open limit. |
| INTERRUPT loop | INTERRUPT | Loop wire connection for a plug-in loop detector when the loop is on the outside of the gate. Holds open gate at open limit; stops and reverses a closing gate; pauses Timer-to-Close at open limit. |
Per LiftMaster, at least two external monitored entrapment protection devices are required prior to gate movement, one in the open and one in the closed direction, and only ONE monitored device may be connected to each input. See page 56 of the manual for the "SAMS Wiring with the Relays Not Energized" example.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 39.
Solar Panels
Solar panels are not provided (see Accessories). LiftMaster's solar appendix is on pages 50 to 54 of the manual.
Solar application requirements
33AH battery requirements:
- Large metal control box for solar applications (Model XLSOLARCONTUL).
- A minimum of two 10W solar panels in series (Model SP10W12V).
- A maximum of six 10W solar panels (Model SP10W12V), in a configuration of three sets of two 10W paralleled panels put in series.
- Two 33AH batteries (Model A12330SGLPK).
- Solar battery harness (Model K94-37236).
- Battery tray (Model K10-36183).
7AH battery requirements:
- Standard control box for solar applications (Model LA500CONTUL).
- A minimum of two 10W solar panels in series (Model SP10W12V).
- A maximum of six 10W solar panels (Model SP10W12V), in a configuration of three sets of two 10W paralleled panels put in series.
- Two 7AH batteries (29-NP712).
- Solar battery harness (Model K94-37236).
LiftMaster notes that photoelectric sensor heaters (models LMRRUL and LMTBUL) are NOT recommended in solar applications.
Solar zones
Solar panel recommendations are based upon the average solar radiation and the temperature effects on batteries in the given zones as shown on the map in the manual (page 50). Local geography and weather conditions may require additional solar panels. Solar powered gate operator installations are not supported in northern climates due to cold weather and a reduced number of hours of sunlight during the winter months. The cycles/day ratings are approximations; ratings vary based on gate construction, installation, and temperature. Solar panels cannot be installed in areas that experience long periods of heavy fog, lake effect snow, or rain.
Solar usage guide
LA500UL typical system standby battery current consumption (mA), 24V system (page 51)
Swipe sideways to see all columns.
| Feature | Current draw |
|---|---|
| Main board with no radios programmed | 2.7 mA |
| One or more LiftMaster remote controls programmed | +1 mA |
| myQ device or wireless dual gate programmed | +2.4 mA |
| Expansion board | +11.1 mA |
| Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board) | +3.8 mA |
Add up the current draw by feature and accessory to determine total current draw. For single-gate cycles per day by zone, panel wattage, battery size (7AH or 33AH), and battery current draw, see the solar usage guide tables on pages 51 and 52 of the manual (single and dual gate). LiftMaster states that the cycles/day ratings are approximations.
Position and installation
The location of the panel(s) is critical to the success of the installation. In general, the panel(s) should be mounted using the provided angle bracket facing due south, in an area clear of all obstructions and shade from buildings and trees. If the panel(s) is not casting a shadow, the battery is not being charged. Tall trees or buildings that do not shade the solar panel(s) in the summer could shade them during the winter months when the sun sits lower in the sky. Solar panel(s) MUST be installed facing south; use a compass to determine direction. LiftMaster's general instructions (your installation may vary slightly depending on the solar panel purchased):
- Position the mounting bracket on the mounting surface. Mark and drill holes.
- Secure the solar panel to the mounting bracket using the hex bolts, hex nuts and washers provided.
- Secure the solar panel to the mounting surface using lag screws provided.
Wire the batteries and the solar panels
Solar panel applications require the Solar Harness Kit model K94-37236 (see Accessories). LiftMaster's wiring drawings for the batteries and the 20W, 40W, and 60W solar panel applications are on page 54 of the manual. If you are using LiftMaster 12V panels, you must use two 12V panels, as this is a 24V system.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 50 to 54.
LiftMaster LA500UL Adjustment
Limit and Force Adjustment
To reduce the risk of SEVERE INJURY or DEATH:
- Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate.
- Too much force on the gate will interfere with proper operation of the safety reversal system.
- NEVER increase force beyond the minimum amount required to move the gate.
- NEVER use force adjustments to compensate for a binding or sticking gate.
- If one control (force or travel limits) is adjusted, the other control may also need adjustment.
- After ANY adjustments are made, the safety reversal system MUST be tested. The gate MUST reverse on contact with an object.
The operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The electronic controls sense the amount of force required to open and close the gate. The force is adjusted automatically when you program the limits but should be fine tuned using the REVERSAL FORCE dial on the control board to compensate for environmental changes. The limit setup LEDs (next to the SET OPEN and SET CLOSE buttons) indicate the status of the limits. The limits can be set using the control board or a remote control (see Limit Setup with a Remote Control); setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP, and LiftMaster recommends the Security+ 2.0 remote control Model 813LMX (not an SP3 remote control) for this. The TEST buttons on the control board will not work until the limits have been set and the required entrapment protection devices are installed.
LA500UL limit setup LEDs
Swipe sideways to see all columns.
| SET OPEN LED | SET CLOSE LED | Operator mode | Explanation (LiftMaster) |
|---|---|---|---|
| OFF | OFF | NORMAL MODE | Limits are set |
| BLINKING | BLINKING | LIMIT SETTING MODE | Limits are not set |
| BLINKING | ON | LIMIT SETTING MODE | Open limit is not set |
| ON | BLINKING | LIMIT SETTING MODE | Close limit is not set |
| ON | ON | LIMIT SETTING MODE | Limits are set |
Initial limits and force adjustments (control board)
For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. If a mistake is made while programming the limits, press the reset button to start over.
- Set the GATE switch to the 1 position.
- Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
- Press and hold the MOVE GATE buttons to move the gate to the open or close limit.
- Press and release the SET CLOSE or SET OPEN button depending on which limit is being set.
- Press and hold the MOVE GATE button to move the gate to the other limit.
- Press and release the SET CLOSE or SET OPEN button depending on which limit is being set. The operator will exit limit setting mode.*
- Cycle the gate open and close using the TEST BUTTONS. This automatically sets the force.
- For dual gates, set the GATE switch to the 2 position and repeat steps 2 to 7.
When the limits are set properly the operator will automatically exit limit setting mode. *Dual gates only: when the limits are set on the secondary gate first, the control board will not exit the limit setting mode until the limits are set on the primary gate.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 23.
Fine tune the force
Once the initial limits have been set, the REVERSAL FORCE dial on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel. The dial is set to minimum at the factory. Based on the length and weight of the gate it may be necessary to make additional force adjustments. The force setting should be high enough that the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a person. The force setting is the same for both the open and close gate directions.
- Open and close the gate with the TEST BUTTONS.
- If the gate stops or reverses before reaching the fully open or closed position, increase the force by turning the force control slightly clockwise.
- Perform the "Obstruction Test" after every limit and force setting adjustment.
Adjust the limits. After both limits are set and the operator is ready to run, one limit can be adjusted independently from the other by following steps 1 to 3 of the initial limits and force adjustment procedure.
Obstruction test
The operator is equipped with an inherent (built into the operator) obstruction sensing device. If the gate encounters an obstruction during motion, the operator will reverse direction of the gate and then stop. This procedure tests ONLY the inherent obstruction sensing device:
- Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and close limit positions.
- Either place an object between the open gate and the fixed closed catch post or obstruct the gate by hand. Make sure that any external entrapment protection devices will NOT be activated by the object.
- Run the gate in the close direction. The gate should stop and reverse upon contact with the object. If the gate does not reverse off the object, reduce the force setting by turning the force control slightly counter-clockwise. The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with an object.
- Repeat the test for the open direction.
Test the operator after any adjustments are made.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 24.
Limit Setup with a Remote Control
To set the limits using a remote control, you first need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. LiftMaster recommends NOT using an SP3 remote control and instead using the Security+ 2.0 remote control Model 813LMX (see How to Program a Remote Control). For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. Ensure the gate is closed.
Initial limits and force adjustment
- Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
- Press and hold the OPEN or CLOSE button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
- Once the gate is in the desired open position, press and release the STOP button on the remote control.
- Press and release the OPEN button on the remote control again to set the open limit.
- Press and hold the CLOSE or OPEN button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons.
- Once the gate is in the desired close position, press and release the STOP button on the remote control.
- Press and release the CLOSE button on the remote control again to set the close limit.
- Cycle the gate open and close. This automatically sets the force.
Adjust the limits
If the limits have already been set, the operator will exit limit setting mode after resetting each limit.
Set the close limit only
- Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
- Press and hold the CLOSE button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
- Once the gate is in the desired close position, press and release the STOP button on the remote control.
- Press and release the CLOSE button on the remote control again to set the close limit. When the close limit is set properly the operator will automatically exit limit setting mode.
Set the open limit only
- Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
- Press and hold the OPEN button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control.
- Once the gate is in the desired open position, press and release the STOP button on the remote control.
- Press and release the OPEN button on the remote control again to set the open limit. When the open limit is set properly the operator will automatically exit limit setting mode.
Refer to the Adjustment section and follow the instructions for Fine Tune the Force and Obstruction Test; perform the obstruction test after every limit and force setting adjustment.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 55.
LiftMaster LA500UL Programming
How to Program a Remote Control
A total of 50 Security+ 2.0 remote controls or KPW250 keypads and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the operator's memory is full it will exit the programming mode and the remote control will not be programmed; the memory will need to be erased before programming any additional remote controls. If installing an 86LM to extend the range of the remote controls DO NOT straighten the antenna.
LiftMaster recommends the Security+ 2.0 remote control Model 813LMX. There are 3 different options for programming the Security+ 2.0 remote control, depending on how you would like the remote control to function:
Single button as OPEN only
- Press and release the LEARN button (operator will beep and green XMITTER LED will light). The operator will time out of programming mode after 30 seconds.
- Press the OPEN button.
- Press the remote control button that you would like to program.
Single button (SBC) as OPEN, CLOSE, and STOP
- Press and release the LEARN button (operator will beep and green XMITTER LED will light). The operator will time out of programming mode after 30 seconds.
- Press the remote control button that you would like to program.
Three separate buttons as OPEN, CLOSE, and STOP
- Press and release the LEARN button (operator will beep and green XMITTER LED will light). The operator will time out of programming mode after 30 seconds.
- Press the OPEN, CLOSE, or STOP button, depending on the desired function.
- Press the remote control button that you would like to program.
The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program additional Security+ 2.0 remote controls or remote control buttons, repeat the programming steps above.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 25.
Programming Security+ 3.0 (SP3) MAX remote controls (not provided)
CAUTION: the gate will move during programming and verification. Ensure the area of the gate, including the entire path of motion and all entrapment zones, are clear of people, vehicles, and obstructions during programming.
The MAX versions of SP3 remote controls that are compatible with the LA500UL are the 1-button CH361, the 2-button L932M and CH382, and the 3-button L993M and CH363. The remote control buttons are pre-set to Security+ 3.0 out of the box. Read these instructions in their entirety before programming. These instructions program the remote for single-button control of gate open/close/stop; if your application requires 3-button functionality (buttons assigned separately to open, close, and stop), LiftMaster recommends instead using the Security+ 2.0 E-DIP remote control 813LMX.
Step 1, put the SP3 remote control into programming mode
- 1-button remote (CH361): press and release the remote button 6 times within 4 seconds. The red LED will turn solid to confirm programming mode is active.
- 2-button remote (L932M, CH382): press and hold both buttons simultaneously until the red LED turns solid (typically 6 seconds), then release the buttons.
- 3-button remote (L993M, CH363): press and hold the two smaller buttons simultaneously until the red LED turns solid (typically 6 seconds), then release the buttons.
Step 2, program to the gate operator
- Locate the LEARN button on the gate operator control board.
- Press and release the LEARN button to put the gate operator into programming mode. The small green XMITTER LED next to the LEARN button will light up.
- Make sure the LED on the remote is solid, which indicates it is in programming mode.
- On your remote, decide which button you want to program and press it twice in quick succession. The remote will begin transmitting, during which time the LEARN LED on the gate operator will flash once and then turn off, confirming the remote has been recognized.
- The LED on your remote will continue flashing until pairing is complete.
- When the gate begins to move, immediately press and release any button on the remote. This will complete the programming.
To program additional SP3 remote controls, repeat the programming steps above.
Step 3, verify programming
- Ensure the operator/receiver is no longer in LEARN mode (the LEARN LED will be OFF).
- Press the programmed button on your remote. If successful, the gate will move. If unsuccessful, repeat Steps 1 and 2.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 26 to 27.
Instructions for programming Security+ 3.0 keypads and/or universal remote controls are located on the LiftMaster support site (LiftMaster's page 27 also gives a QR code).
How to Connect the LA500UL to the LiftMaster Internet Gateway and the CAPXL/CAPXLV
The LiftMaster Internet Gateway is not provided. To program the operator to the LiftMaster Internet Gateway (page 28):
Pair the LiftMaster Internet Gateway
- Press and release the LEARN button on the primary operator. The green XMITTER LED will light. The operator will time out of programming mode after 180 seconds.
- Connect the ethernet cable to the LiftMaster Internet Gateway and the router.
- Connect power to the LiftMaster Internet Gateway.
- Download the myQ app.
- Set up an account and follow the app instructions to add your gate operator.
- The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful. The gate operator can then be controlled through the myQ app.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 28.
All Security Equipment note. The LiftMaster Internet Gateway (Model 828LM) is a separate accessory. See the LiftMaster Internet Gateway 828LM product page for current availability.
CAPXL/CAPXLV connected access portal
The CAPXL/CAPXLV can communicate wirelessly to LiftMaster gate operators to send open commands, monitor gate position, and send email notifications if an error occurs in the operator (email notifications are configured in myQ Business). Up to 8 gate operators can be paired with the CAPXL/CAPXLV, one for each primary and auxiliary relay. If using dual gates, program the CAPXL/CAPXLV to the primary operator. For other Smart Video Intercom models (CAPXLV2, CAPXM, CAPXS), refer to the instructions of the SVI.
Program the CAPXL/CAPXLV
- Enter Admin Mode: flip dipswitch #1 to the ON position. For new installations, press the login button without entering information in the Admin Username and Admin Password fields.
- Select Outputs and Relay: select the Outputs tab, then select the desired relay on the left-hand side (1 through 4).
- Press the LEARN button on the gate operator: press and release the LEARN button on the primary operator. The green XMITTER LED will light.
- Press the LEARN button on the gate operator again: press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light.
- Select LEARN on the display: the LEARN button will go from blue to red. The gate operator and the CAPXL/CAPXLV will beep once and the NETWORK LED on the gate operator will turn off, indicating programming is successful. Four beeps/blinks indicate you are not programming to the primary operator.
- Validate functionality by selecting Test Relay on the CAPXL/CAPXLV display.
For more information refer to the CAPXL/CAPXLV documentation.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 28 to 29.
Constant Pressure Override and Erase Procedures (page 29)
Constant Pressure Override (CPO)
Constant Pressure Override is for use with KPW5 and KPW250 keypads (not provided). The KPW5/KPW250 wireless commercial keypads are security keypads and can only be programmed to ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions). The feature is intended to temporarily override a fault in the entrapment protection system, in order to operate the gate until the external entrapment protection device is realigned or repaired. Use the feature only in line of sight of the gate when no obstructions to travel are present. External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless edge sensors. Be sure to repair or replace these devices promptly if they are not working properly.
- Enter a valid 4-digit PIN.
- Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will sound until the limit is met and/or # is released.
- The operator will stop when either the operator reaches a limit or the user releases #.
Erase all codes
- Press and release the LEARN button (operator will beep and green XMITTER LED will light).
- Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote control codes are now erased.
Erase limits
- To erase the limits, press and hold the SET OPEN and SET CLOSE buttons simultaneously (5 seconds) until both the SET OPEN and SET CLOSE LEDs blink rapidly and the operator beeps.
- Release the buttons and the SET OPEN and SET CLOSE LEDs will blink slowly, indicating the limits will need to be set.
Remove and erase monitored entrapment protection devices
- Remove the entrapment protection device wires from the terminal block.
- Press and release the SET OPEN and SET CLOSE buttons simultaneously. The SET OPEN and SET CLOSE LEDs will turn on (entering learn limit mode).
- Press and release both the SET OPEN and SET CLOSE buttons again to turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 29.
LiftMaster LA500UL Operation
Gate Operator Setup Examples
LiftMaster provides example setups for the gate operator; your specific site requirements may be different. Always set up the operator system to the site requirements, including all necessary entrapment protection devices.
- Residential: one to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns.
- Commercial/general access: a residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns.
- Commercial: business site where security (gate closed) is important.
- Industrial: large business site where security is required.
LiftMaster example LA500UL settings by site type (page 30)
Swipe sideways to see all columns.
| Setting | Residential | Commercial/general access | Commercial | Industrial |
|---|---|---|---|---|
| Quick Close switch setting | Normally set to OFF. Normal gate close (timer or control). | Normally set to OFF. Normal gate close (timer or control). | Normally set to OFF. Normal gate close (timer or control). | Set to ON, so that gate closes immediately after vehicle passes CLOSE EYES/Interrupt loop. |
| AC Fail Open switch setting | Normally set to BATT. Run on battery if AC power fails. | Normally set to BATT. For local jurisdiction requirement, set to OPEN so that the gate will open approximately 15 seconds after AC power fail. | Normally set to BATT. Run on battery if AC power fails. | Normally set to BATT. Run on battery if AC power fails. |
| Low Battery switch setting | Normally set to OPEN. If powered from battery and battery is low, gate automatically opens and stays open. | Normally set to OPEN. If powered from battery and battery is low, gate automatically opens and stays open. | Normally set to CLOSE. If powered from battery and battery is low, gate stays closed. | Normally set to CLOSE. If powered from battery and battery is low, gate stays closed. |
| Anti-Tail switch setting | Normally set to OFF. CLOSE EYES/Interrupt loop reverses a closing gate. | Normally set to OFF. CLOSE EYES/Interrupt loop reverses a closing gate. | Set to ON. In attempt to prevent vehicle tail- gating, CLOSE EYES/ Interrupt loop pauses a closing gate. | Set to ON. In attempt to prevent vehicle tail- gating, CLOSE EYES/ Interrupt loop pauses a closing gate. |
| Bipart Delay switch setting | For DUAL-GATE site, set to ON for gate that delays upon opening. | For DUAL-GATE site, set to ON for gate that delays upon opening. | For DUAL-GATE site, set to ON for gate that delays upon opening. | For DUAL-GATE site, set to ON for gate that delays upon opening. |
| Aux Relay Out - Open Limit Switch | Typically not required. | Use with SAMS (Sequence Access Management System). | 1. Use with SAMS (Sequence Access Management System). 2. Connect “Gate Open” indicator (e.g. light). | 1. Use with SAMS (Sequence Access Management System). 2. Connect “Gate Open” indicator (e.g. light). |
| Aux Relay Out - Close Limit Switch | Typically not required. | Typically not required. | Connect “Gate Close/ Secure” indicator (e.g. light). | Connect “Gate Close/ Secure” indicator (e.g. light). |
| Aux Relay Out - Gate Motion | Attach alert signal (audible or visual alert system). | Attach alert signal (audible or visual alert system). | Attach alert signal (audible or visual alert system). | Attach alert signal (audible or visual alert system). |
| Aux Relay Out - Pre- Motion Delay | Attach alert signal (audible or visual alert system). | Attach alert signal (audible or visual alert system). | Attach alert signal (audible or visual alert system). | Attach alert signal (audible or visual alert system). |
| Aux Relay Out - Power | Attach visual alert to know when system is charging batteries (i.e. not running on batteries). | Attach visual alert to know when system is charging batteries (i.e. not running on batteries). | Attach visual alert to know when system is charging batteries (i.e. not running on batteries). | Attach visual alert to know when system is charging batteries (i.e. not running on batteries). |
| Cycle Quantity Feedback | Use during servicing only to determine operator cycles. | Use during servicing only to determine operator cycles. | Use during servicing only to determine operator cycles. | Use during servicing only to determine operator cycles. |
| Fire Dept Open Input | Typically not required. | Connect emergency access system (Knox box switch, SOS system, etc.). | Typically not required. | Typically not required. |
Source: LiftMaster manual, 114-6272-000 Rev. A, page 33.
LA500UL Control Board Overview
LiftMaster identifies these control board features (numbers match the manual's callouts on page 31):
- SET OPEN button: sets the OPEN limit (see Limit and Force Adjustment).
- SET CLOSE button: sets the CLOSE limit.
- MOVE GATE buttons: open or close the gate when the operator is in limit setting mode.
- BATT FAIL: when AC power is OFF and battery voltage is critically low the gate will latch at a limit until AC power is restored or battery voltage increases. The option select switch set to OPEN forces the gate to automatically open and then latch at the OPEN limit until AC power is restored or battery voltage increases. The option select switch set to CLOSE forces the gate to latch at the CLOSE limit if at the CLOSE limit or on the next CLOSE command until AC power is restored or battery voltage increases. Constant pressure on a hard command input overrides to open or close the gate. Critically low battery is less than 23 V.
- BIPART DELAY switch: the LOCK/BIPART DELAY switch is used only for dual gates (see Set the bipart delay).
- LEARN button: used for programming remote controls and the network.
- TIMER-TO-CLOSE (TTC) dial: can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the TTC is set to OFF, the gate will remain open until the operator receives another command from a control. Rotate the dial to the desired setting; the range is 0 to 180 seconds, and 0 seconds is OFF. Any radio command, single button control, or CLOSE command on the control board before the TTC expires will close the gate. The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IRs).
- REVERSAL FORCE dial: fine tunes the force (see fine tune the force).
- TEST BUTTONS: operate the gate (OPEN, STOP and CLOSE).
- STATUS LEDs: indicate the status of the operator (see the Control Board LEDs).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 31.
Manual Release
In case of a power failure, the operator can be disengaged from the gate. LiftMaster notes that the release action may sometimes feel stiff or jerky, which is normal and has no effect on function. It is also normal for the operator to run slow right after a disconnect or complete loss of AC/battery power (the operator will need to run a complete open and close cycle).
Release (manual mode)
- Insert the key into the lock.
- Turn the key counter-clockwise 180°.
- Turn the release lever counter-clockwise 180°. The operator is in manual mode and the gate can be opened and closed manually.
The lock relay will activate then turn off after 2 minutes to conserve power.
Engage
- Turn the release lever clockwise 180°. This engages the motor.
- Turn the key clockwise 180°. This locks the release lever.
- Remove the key and store it in a safe place. The operator is now engaged.
Use the manual release ONLY when the gate is not moving.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 32.
LA500UL Reset Button
The reset button is located on the side of the control box and serves several functions (LiftMaster, page 32):
- Press the reset button to stop a moving gate during a normal open/close cycle, like a stop button.
- Press the reset button once while the gate is in the open position to disable the Timer-to-Close. The gate will stay in the open position. To restart the Timer-to-Close, either press the reset button or activate the gate with a programmed remote control.
- Press the reset button to shut off the alarm and reset the operator.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 32.
Party Mode
Press the reset button once while the gate is in the open position to disable the Timer-to-Close; the gate will stay in the open position. To restart the Timer-to-Close, either press the reset button or activate the gate with a programmed remote control. Party mode can also be enabled from a KPW5 or KPW250 keypad (not provided):
- Enter a valid 4-digit PIN when the gate is at the open limit and the timer is running.
- The operator will chirp, indicating the timer is canceled.
To restart the gate, either re-enter the 4-digit PIN or activate a hard input or a programmed remote. LiftMaster notes that using party mode at a solar site will deplete the batteries.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 32.
LA500UL Operator Alarm
When the inherent force of the operator detects any of the following twice consecutively, the alarm will sound for up to 5 minutes and the operator will need to be reset:
- The gate is hitting an obstruction.
- The operator arm or gate is incorrectly installed.
- The gate does not meet specifications.
- Gate hinges are too tight or broken and the gate is not moving freely.
- The gate is moving and a car pushes the gate.
- A foreign object is on the gate frame while the gate is moving.
- The gate hits the driveway or curb and gets stuck or bent in an awkward position.
Remove any obstructions, then press the reset button to shut off the alarm and reset the operator. After the operator is reset, normal functions will resume. The operator alarm will beep 3 times with a command if the battery is low (see battery problems).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 33.
LA500UL Remote Control Operation
Single button control (SBC) functionality. Once the remote control has been programmed, the operator will operate as follows: when the gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote control will stop the gate and the next activation of the remote control will close the gate. When the gate is in the open position, activation of the remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open the gate. See How to Program a Remote Control for the other programming options.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 33.
LiftMaster LA500UL Troubleshooting
This section follows the troubleshooting chart in LiftMaster's LA500UL installation manual (document 114-6272-000 Rev. A). The full chart below keeps LiftMaster's wording; the problem-specific sections after it restate rows of the chart in task order and are condensed. Disconnect power (AC or solar and battery) before servicing the operator, and replace a fuse only with one of the same type and rating.
Documentation note. In the chart row "Gate opens, but will not close with transmitter or Timer-to-Close" (page 44), the possible causes are lettered a to e (five items) but the recommended actions are lettered a to g (seven items), so the letters do not correspond beyond the first two. The "Quick Close not working correctly" row (page 45) prints its causes starting at letter c (three items) and its actions as a to c. The chart below shows both lists exactly as printed.
- Gate will not open or does not move
- Gate opens but will not close
- Operator has no power
- Remote control does not operate the gate
- Safety device problems
- Battery and solar problems
- Complete troubleshooting chart (30 symptoms)
- Control board LEDs
LiftMaster LA500UL Troubleshooting Chart
LiftMaster LA500UL troubleshooting chart (letters in each row correspond except where the documentation note says otherwise)
Swipe sideways to see all columns.
| Symptom | Possible causes | Recommended diagnostic action | Manual reference |
|---|---|---|---|
| Operator does not run and diagnostic display not on. |
|
|
Troubleshooting Chart, page 43 |
| Control board powers up, but motor does not run. |
|
|
Troubleshooting Chart, page 43 |
| Arm moves, but cannot set correct limits. |
|
|
Troubleshooting Chart, page 43 |
| Gate does not fully open or fully close when setting limits. |
|
|
Troubleshooting Chart, page 43 |
| Operator does not respond to a wired control/command (example: Open, Close, SBC, etc.) |
|
|
Troubleshooting Chart, page 43 |
| Operator does not respond to a wireless control or transmitter. |
|
|
Troubleshooting Chart, page 43 |
| Gate stops during travel and reverses immediately. |
|
|
Troubleshooting Chart, page 43 |
| Gate opens, but will not close with transmitter or Timer-to-Close. |
|
|
Troubleshooting Chart, page 44 |
| Gate closes, but will not open. |
|
|
Troubleshooting Chart, page 44 |
| Exit loop activation does not cause gate to open. |
|
|
Troubleshooting Chart, page 44 |
| Interrupt loop does not cause gate to stop and reverse. |
|
|
Troubleshooting Chart, page 44 |
| Shadow loop does not keep gate at open limit. |
|
|
Troubleshooting Chart, page 44 |
| Obstruction in gate's path does not cause gate to stop and reverse. |
|
|
Troubleshooting Chart, page 44 |
| Photoelectric sensor does not stop or reverse gate. |
|
|
Troubleshooting Chart, page 44 |
| Edge sensor does not stop or reverse gate. |
|
|
Troubleshooting Chart, page 44 |
| Alarm sounds for 5 minutes or alarm sounds with a command. |
|
|
Troubleshooting Chart, page 44 |
| Alarm beeps three times with a command. |
|
|
Troubleshooting Chart, page 44 |
| On dual-gate system, incorrect gate opens first or closes first. |
|
|
Troubleshooting Chart, page 44 |
| Alarm beeps when running. |
|
|
Troubleshooting Chart, page 44 |
| Expansion board function not controlling gate. |
|
|
Troubleshooting Chart, page 45 |
| Maglock not working correctly. |
|
|
Troubleshooting Chart, page 45 |
| Solenoid lock not working correctly. |
|
|
Troubleshooting Chart, page 45 |
| Switched (SW) Accessory power remaining on. |
|
|
Troubleshooting Chart, page 45 |
| Accessories connected to Switch (SW) Accessory power not working correctly, turning of,f or resetting. |
|
|
Troubleshooting Chart, page 45 |
| Accessories connected to Accessory power not working correctly, turning of,f or resetting. |
|
|
Troubleshooting Chart, page 45 |
| Quick Close not working correctly. |
|
|
Troubleshooting Chart, page 45 |
| Anti-Tailgating not working correctly. |
|
|
Troubleshooting Chart, page 45 |
| AUX Relay not working correctly. |
|
|
Troubleshooting Chart, page 45 |
| Solar operator not getting enough cycles per day. |
|
|
Troubleshooting Chart, page 45 |
| Solar operator, insufficient standby time. |
|
|
Troubleshooting Chart, page 45 |
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 43 to 45.
Gate Will Not Open or the LiftMaster LA500UL Does Not Move
If a LiftMaster LA500UL gate will not open or the operator does not move, LiftMaster's troubleshooting chart separates several conditions. Find the one that matches what you see.
The control board powers up, but the motor does not run
LiftMaster lists these possible causes and checks (chart row):
- Reset switch is stuck: Check reset switch.
- Stop button active or jumper not in place for stop circuit: Check Stop button is not "stuck on", or verify that the stop button is a normally closed circuit, or put a jumper on the stop circuit.
- If on battery power only, low or dead batteries: Charges batteries by AC or solar power or replace batteries.
- Open or Close input active: Check all Open and Close inputs for a "stuck on" input.
- Entrapment Protection Device active: Check all Entrapment Protection Device inputs for a "stuck on" sensor.
- Vehicle loop detector or probe active: Check all vehicle detector inputs for a "stuck on" detector.
- Inoperable control board: Replace inoperable control board.
The gate closes but will not open
LiftMaster lists these possible causes and checks (chart row):
- Vehicle loop detector active: Check all vehicle detector inputs for an active detector.
- Low battery with LOW BATT option set to CLOSE: Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
The operator does not respond to a command
For wired controls such as Open, Close, or SBC, see the chart row. For remotes and transmitters, see remote control problems.
The arm moves but limits cannot be set correctly
See the chart row for "cannot set correct limits" and the chart row for "does not fully open or fully close when setting limits." See Limit and Force Adjustment.
The gate stops during travel and reverses immediately
LiftMaster lists these possible causes and checks (chart row):
- Control (Open, Close) becoming active: Check all Open and Close inputs for an active input.
- Vehicle loop detector active: Check all vehicle detector inputs for an active detector.
- Low battery voltage: Battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
- Entrapment protection was activated while moving: Check gate path for obstructions and remove. If there are no obstructions in gate path, manually disconnect the gate, and ensure it moves easily limit to limit. Repair gate as needed.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 43 to 44.
Gate Opens but Will Not Close on the LiftMaster LA500UL
For a gate that opens but will not close with a transmitter or the Timer-to-Close, LiftMaster's chart (chart row) prints its causes and actions as two separate lists:
Possible causes (as printed):
- Open control active.
- Vehicle loop detector active.
- Fire Dept input active.
- Timer-to-Close not set.
- Close Entrapment Protection Device active.
Recommended actions (as printed):
- Check all Open inputs for an active input.
- Check all vehicle detector inputs for an active detector.
- Check AC power and AC Fail option setting.
- Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
- Check Fire Dept input.
- Check Timer-to-Close (TTC) setting.
- Check all Entrapment Protection Device inputs for an active sensor.
If the display shows a code, see code 60 and codes 61 to 66 and 70 to 75 for entrapment protection inputs. LiftMaster's chart also has rows for an exit loop that does not open the gate, an interrupt loop that does not stop and reverse the gate, and a shadow loop that does not keep the gate at the open limit.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 44.
LiftMaster LA500UL Has No Power or the Display Is Off
If the LiftMaster LA500UL does not run and the diagnostic display is not on, LiftMaster lists these possible causes and checks (chart row):
- No power to control board: Check AC and battery power.
- Open fuse: Check fuses.
- If on battery power only, low or dead batteries: Charge batteries by AC or solar power or replace batteries.
- Inoperable control board: Replace inoperable control board.
For battery connections see Batteries. Related codes in LiftMaster's table include code 53 and code 54.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 43.
LiftMaster LA500UL Remote Control Does Not Operate the Gate
For a wireless control or transmitter that does not operate a LiftMaster LA500UL gate, LiftMaster lists these causes and checks (chart row):
- Check XMITTER LED when wireless control is active: Activate wireless control and check XMITTER LED is on. Re-learn wireless control/transmitter to control board. Replace wireless control as needed.
- Stop button is active: Check Stop button is not "stuck on".
- Reset button is stuck: Check reset button.
- Poor radio reception: Check if similar wired control operates correctly. Check if wireless controls work properly when within a few feet of operator. Check operator's antenna and antenna wire. Check other wireless controls or devices.
To re-learn a remote, see How to Program a Remote Control. If the operator's memory is full, LiftMaster notes that the memory must be erased before more remote controls can be programmed (Erase All Codes).
Source: LiftMaster manual, 114-6272-000 Rev. A, page 43.
LiftMaster LA500UL Safety Device Problems
LiftMaster's chart covers these safety device symptoms:
- Photoelectric sensor does not stop or reverse the gate (row): Incorrect photoelectric sensor wiring: Check photoelectric sensor wiring. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction. Inoperable photoelectric sensor: Replace inoperable photoelectric sensor. Retest that obstructing photoelectric sensor causes moving gate to stop, and may reverse direction.
- Edge sensor does not stop or reverse the gate (row): Incorrect edge sensor wiring: Check edge sensor wiring. Retest that activating edge sensor causes moving gate to stop and reverse direction. Inoperable edge sensor: Replace inoperable edge sensor. Retest that activating edge sensor causes moving gate to stop and reverse direction.
- Obstruction does not cause the gate to stop and reverse (row): Force adjustment needed: Refer to the Adjustment section to conduct the obstruction test and perform the proper force adjustment that is needed.
- Alarm sounds for 5 minutes or with a command (row): Double entrapment occurred (two obstructions within a single activation): Check for cause of entrapment (obstruction) detection and correct. Press the reset button to shut off alarm and reset the operator.
- Expansion board function not controlling the gate (row): Inoperable main board to expansion board wiring: Check main board to expansion board wiring. If required, replace wire cable. Incorrect input wiring to expansion board: Check wiring to all inputs on expansion board. Inoperable expansion board or inoperable main board: Replace inoperable expansion board or inoperable main board.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 44 to 45.
LiftMaster LA500UL Battery and Solar Problems
The operator alarm beeps 3 times with a command when the battery is low (see chart row). Critically low battery is less than 23 V (see BATT FAIL). For solar operators, LiftMaster's chart has two rows:
- Alarm beeps three times with a command (row): Low battery: Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries.
- Solar operator not getting enough cycles per day (row): Insufficient panel wattage: Add more solar panels. Excessive accessory power draw: Reduce the accessory power draw by using LiftMaster low power accessories. Old batteries: Replace batteries. Solar panels are not getting enough sunlight: Relocate the solar panels away from obstructions (trees, buildings, etc.).
- Solar operator, insufficient standby time (row): Insufficient panel wattage: Add more solar panels. Excessive accessory power draw: Reduce the accessory power draw by using LiftMaster low power accessories. Battery capacity too low: Use batteries with higher amp hour (AH) rating.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 44 to 45.
LA500UL Control Board LEDs
LA500UL control board status LEDs
Swipe sideways to see all columns.
| LED | State | Definition (LiftMaster) |
|---|---|---|
| INPUT POWER | OFF | OFF state |
| INPUT POWER | ON | AC charger or Solar power available |
| BATT CHARGING | OFF | Not charging |
| BATT CHARGING | ON | Three stage battery charging |
| TIMER | OFF | The timer is disabled |
| TIMER | ON | The timer is enabled |
| TIMER | MEDIUM BLINK (1 blink per second) | The timer is running |
| TIMER | FAST BLINK (2 blinks per second) | The timer is paused |
| TIMER | FASTEST BLINK (8 blinks per second) | The timer is canceled |
| GATE MOVING | OFF | The gate is stopped |
| GATE MOVING | ON | The gate is opening or closing |
| GATE MOVING | MEDIUM BLINK (1 blink per second) | Operator is in E1 (single entrapment) |
| GATE MOVING | FASTEST BLINK (8 blinks per second) | The operator is in E2 (double entrapment) |
| BATT LOW | OFF | No battery error |
| BATT LOW | ON | Battery low |
| BATT LOW | MEDIUM BLINK (1 blink per second) | Battery critically low |
| ACC PWR OVLD | OFF | OFF state |
| ACC PWR OVLD | ON | Accessory overload protector opened |
LA500UL control board input LEDs
Swipe sideways to see all columns.
| LED | State | Definition (LiftMaster) |
|---|---|---|
| SBC INPUT | OFF | Input inactive |
| SBC INPUT | ON | Input active |
| SBC INPUT | BLINK | Input active on other operator |
| FIRE DEPT INPUT | OFF | Input inactive |
| FIRE DEPT INPUT | ON | Input active |
| FIRE DEPT INPUT | BLINK | Input active on other operator |
| EXIT | OFF | Input inactive |
| EXIT | ON | Input active |
| EXIT | BLINK | Input active on other operator |
| SHADOW | OFF | Input inactive |
| SHADOW | ON | Input active |
| SHADOW | BLINK | Input active on other operator |
| CLOSE EYES/INTERRUPT | OFF | Input inactive |
| CLOSE EYES/INTERRUPT | ON | Input active |
| CLOSE EYES/INTERRUPT | BLINK | Input active on other operator |
| CLOSE EDGE | OFF | Input inactive |
| CLOSE EDGE | ON | Input active |
| CLOSE EDGE | BLINK | Input active on other operator |
| OPEN EYES/EDGE | OFF | Input inactive |
| OPEN EYES/EDGE | ON | Input active |
| OPEN EYES/EDGE | BLINK | Input active on other operator |
| LOCK | OFF | Maglock relay inactive |
| LOCK | ON | Maglock relay active |
Source: LiftMaster manual, 114-6272-000 Rev. A, page 37.
LiftMaster LA500UL Diagnostic and Error Codes
The LiftMaster LA500UL control board shows diagnostic codes on its display. Some codes are saved in the code history and some are not; a code that is not saved briefly appears on the display as it occurs, then disappears. When cycling or disconnecting power (AC/DC) to the control board, LiftMaster recommends unplugging the J15 plug.
How to Read LA500UL Diagnostic Codes
- To protect against fire and electrocution: DISCONNECT power (AC or solar and battery) BEFORE installing or servicing the operator.
- For continued protection against fire: replace ONLY with a fuse of the same type and rating.
View the saved codes on the diagnostic display
- Press and hold the STOP button...
- ...then press and hold the CLOSE button...
- ...then press and hold the OPEN button until "Er" shows on the display.
A second later the operator will show the code sequence number followed by the code number. The first number shown is the code sequence number: "01" is the most recent code, and the display will show the sequence of codes that occurred starting with "01" and going up to code "20". The second number is the code itself (31-99, example "31"); use the table below to look it up.
To scroll through the saved codes, press the OPEN button to cycle to the most recent code ("01") and the CLOSE button to cycle to the oldest code (up to "20"). The operator will only keep track of up to 20 codes, then will start saving over the oldest codes as new codes occur.
To exit: press and release the STOP button. The display will also time out after two minutes of inactivity.
Reset the code history
- Press and hold the STOP button for six seconds. The display will show "Er" then "CL" alternately for six seconds.
- Release the STOP button. The code history has now been reset and the display will show "- -" until a new code occurs.
- Press and release the STOP button to exit.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 41.
LiftMaster LA500UL Diagnostic Code Table
Each code below has its own anchor (for example code 60). The wording is LiftMaster's. LiftMaster's table is color-coded by category (LiftMaster system, installed system, informational, external entrapment protection, inherent entrapment protection); see the original table for the color key. The manual groups several codes that share one solution; they are listed separately here.
- 31
- 32
- 33
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 51
- 52
- 53
- 54
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
- 75
- 80
- 81
- 82
- 83
- 84
- 91
- 92
- 93
- 94
- 99
LiftMaster LA500UL diagnostic codes (display shows 31 to 99; code 00 is listed in the manual table)
Swipe sideways to see all columns.
| Code | Meaning (LiftMaster) | Recommended action (LiftMaster) | Saved in code history | Manual reference |
|---|---|---|---|---|
| 31 | Main control board has experienced an internal error. | Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board. | NO | Diagnostic Codes Table, page 39 |
| 32 | Linear Drive Disengaged (Arm 1) | Disengage then re-engage arm. Check wiring and connections. | YES | Diagnostic Codes Table, page 39 |
| 33 | Linear Drive Disengaged (Arm 2) | Disengage then re-engage arm. Check wiring and connections. | YES | Diagnostic Codes Table, page 39 |
| 35 | Max-Run-Time Exceeded Error | Check for an obstruction, then reprogram the limits. | YES | Diagnostic Codes Table, page 39 |
| 36 | Product ID Error | Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. | YES | Diagnostic Codes Table, page 39 |
| 37 | Product ID Failure | Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness. | YES | Diagnostic Codes Table, page 39 |
| 38 | Hard Stop Limit (Arm 1) | Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting). | NO | Diagnostic Codes Table, page 39 |
| 39 | Hard Stop Limit (Arm 2) | Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting). | NO | Diagnostic Codes Table, page 39 |
| 40 | Battery overvoltage | Too much voltage on the battery. Check harness. Make sure there is NOT a 24V battery on a 12V system. | YES | Diagnostic Codes Table, page 39 |
| 41 | Battery overcurrent | Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system. | YES | Diagnostic Codes Table, page 39 |
| 42 | No battery at boot up | Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system. | YES | Diagnostic Codes Table, page 39 |
| 43 | Exit Loop Error | Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only). Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. | YES | Diagnostic Codes Table, page 39 |
| 44 | Shadow Loop Error | Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only). Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. | YES | Diagnostic Codes Table, page 39 |
| 45 | Interrupt Loop Error | Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only). Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. | YES | Diagnostic Codes Table, page 39 |
| 46 | Wireless edge battery low | Replace batteries in wireless edge. | YES | Diagnostic Codes Table, page 39 |
| 51 | Pass-point not detected (Arm 1) | Check yellow pass-point wiring. If limits are not accurate, reprogram. | NO | Diagnostic Codes Table, page 39 |
| 52 | Pass-point not detected (Arm 2) | Check yellow pass-point wiring. If limits are not accurate, reprogram. | NO | Diagnostic Codes Table, page 39 |
| 53 | Brownout occurred | AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot. | YES | Diagnostic Codes Table, page 39 |
| 54 | Wireless Second Operator Communication Error | Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator. | YES | Diagnostic Codes Table, page 39 |
| 60 | Minimum number of monitored entrapment protection devices not installed. | Review monitored entrapment protection device connections. Slide gate operators require a minimum of two external safety devices; one in the close and one in the open direction. | NO | Diagnostic Codes Table, page 39 |
| 61 | CLOSE EYE/INTERRUPT held more than 3 minutes | Check wired input on main control board; check for alignment or obstruction. | YES | Diagnostic Codes Table, page 39 |
| 62 | CLOSE EDGE held more than 3 minutes | Check wired input on main control board; check for alignment or obstruction. | YES | Diagnostic Codes Table, page 39 |
| 63 | OPEN EYE/EDGE held more than 3 minutes | Check wired input on main control board; check for alignment or obstruction. | YES | Diagnostic Codes Table, page 39 |
| 64 | CLOSE EYE/INTERRUPT held more than 3 minutes | Check wired input on expansion board; check for alignment or obstruction. | YES | Diagnostic Codes Table, page 39 |
| 65 | CLOSE EYE/EDGE held more than 3 minutes | Check wired input on expansion board; check for alignment or obstruction. | YES | Diagnostic Codes Table, page 39 |
| 66 | OPEN EYE/EDGE held more than 3 minutes | Check wired input on expansion board; check for alignment or obstruction. | YES | Diagnostic Codes Table, page 39 |
| 67 | Wireless edge triggered more than 3 minutes | Check wired input for wiring issue or obstruction. | YES | Diagnostic Codes Table, page 40 |
| 68 | Wireless edge loss of monitoring | Check wireless edge inputs. | YES | Diagnostic Codes Table, page 40 |
| 69 | Wireless edge triggered | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring. | NO | Diagnostic Codes Table, page 40 |
| 70 | CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board | NO | Diagnostic Codes Table, page 40 |
| 71 | CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board | NO | Diagnostic Codes Table, page 40 |
| 72 | OPEN EYE/EDGE triggered, causing reversal or preventing opening | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board | NO | Diagnostic Codes Table, page 40 |
| 73 | CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. | NO | Diagnostic Codes Table, page 40 |
| 74 | CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. | NO | Diagnostic Codes Table, page 40 |
| 75 | OPEN EYE/EDGE triggered, causing reversal or preventing opening | IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. | NO | Diagnostic Codes Table, page 40 |
| 80 | Close input (EYE/EDGE) communication fault from other operator | Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators. | YES | Diagnostic Codes Table, page 40 |
| 81 | Open input (EYE/EDGE) communication fault from other operator | Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators. | YES | Diagnostic Codes Table, page 40 |
| 82 | Close input (EYE/EDGE) communication fault (expansion board) | Check the connections between the main board and the expansion board. | YES | Diagnostic Codes Table, page 40 |
| 83 | Open input (EYE/EDGE) communication fault (expansion board) | Check the connections between the main board and the expansion board. | YES | Diagnostic Codes Table, page 40 |
| 84 | Non-monitored device detected on the wireless safety system | Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection. | YES | Diagnostic Codes Table, page 40 |
| 91 | Force Reversal (Operator 1) | Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force Adjustment, and Obstruction Test. | YES | Diagnostic Codes Table, page 40 |
| 92 | Force Reversal (Operator 2) | Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force Adjustment, and Obstruction Test. | YES | Diagnostic Codes Table, page 40 |
| 93 | RPM / STALL Reversal (Operator 1) | Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly. | YES | Diagnostic Codes Table, page 40 |
| 94 | RPM / STALL Reversal (Operator 2) | Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly. | YES | Diagnostic Codes Table, page 40 |
| 99 | Normal Operation | No action required. | YES | Diagnostic Codes Table, page 40 |
LiftMaster LA500UL Maintenance
LiftMaster's maintenance instructions for the LA500UL are on page 40 of the manual (document 114-6272-000 Rev. A). Disconnect all power (AC, solar, battery) to the operator before servicing. The operator's AC power switch ONLY turns off AC power to the control board and DOES NOT turn off battery power. ALWAYS disconnect the batteries to service the operator.
Important Safety Instructions
To reduce the risk of SEVERE INJURY or DEATH:
- READ AND FOLLOW ALL INSTRUCTIONS.
- ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
- Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity.
- NEVER let children operate or play with gate controls. Keep the remote control away from children.
- ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
- The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
- Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.
- Use the manual disconnect release ONLY when the gate is NOT moving.
- KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware.
- ALL maintenance MUST be performed by a LiftMaster professional.
- Activate gate ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to gate travel.
- To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part 29-NP712 for replacement batteries.
- SAVE THESE INSTRUCTIONS.
- ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 40.
Maintenance Chart
LiftMaster LA500UL maintenance chart: check at least once every month, 6 months, or 3 years
Swipe sideways to see all columns.
| Description | Task | Month | 6 months | 3 years |
|---|---|---|---|---|
| Entrapment protection devices | Check and test for proper operation | X | ||
| Warning signs | Make sure they are present and replace if worn or broken | X | ||
| Manual release | Check and test for proper operation | X | ||
| Gate | Inspect for wear or damage; ensure it still complies with ASTM F2200, see page 5 | X | ||
| Accessories | Check all for proper operation | X | ||
| Electrical | Inspect all wire connections | X | ||
| Mounting hardware | Check for tightness | X | ||
| Operator | Inspect for wear or damage | X | ||
| Batteries | Replace | X |
LiftMaster's notes: severe or high cycle usage will require more frequent maintenance checks. It is suggested that while at the site, voltage readings be taken at the operator. Using a digital voltmeter, verify that the incoming voltage to the operator is within ten percent of the operator's rating.
Batteries
Batteries will degrade over time depending on temperature and usage. The operator alarm will beep 3 times with a command if the battery is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The batteries contain lead and need to be disposed of properly. The standard control box comes with two 7AH batteries. Shop gate operator batteries.
Source: LiftMaster manual, 114-6272-000 Rev. A, page 40.
LiftMaster LA500UL Repair and Replacement Parts
The tables below list the LA500UL repair parts and part numbers as printed by LiftMaster on pages 57 and 58 of manual 114-6272-000 Rev. A: the standard control box (items 1 to 10), the gate operator arm (items 11 to 16), and the large metal control box parts LiftMaster lists as "not shown."
All Security Equipment note: using these links. The part numbers and descriptions are LiftMaster's. The links in the right-hand column open our category pages or search our catalog for the part number; they do not by themselves confirm that we stock a part or that it fits your operator.
Browse by category: gate operator parts | control boards | motors | batteries | gate operator accessories
LiftMaster adds this note on page 57: as of August 2020, the LA500 arm will no longer have a light lens; the new design will replace the legacy design, and no legacy service kit is available.
LiftMaster LA500UL repair parts as listed by LiftMaster (pages 57 and 58)
Swipe sideways to see all columns.
| Part (LiftMaster description) | LiftMaster part number | Related manual section | Find at All Security Equipment |
|---|---|---|---|
| Standard Plastic Control Box Only (item 1) | K74-39307-1 | Repair parts, pages 57 and 58 | Search K74-39307-1 |
| Outlet (item 2) | K76-36296-1 | Repair parts, pages 57 and 58 | Search K76-36296-1 |
| Control Board Bracket (item 3) | K75-36635 | Repair parts, pages 57 and 58 | Search K75-36635 |
| Control Board (item 4) | K1D8388-1CC | Repair parts, pages 57 and 58 | Browse control boards | Search K1D8388-1CC |
| Expansion Board (item 5) | K1D8387-1CC | Repair parts, pages 57 and 58 | Browse control boards | Search K1D8387-1CC |
| Piezo Alarm (item 6) | K94-36411 | Repair parts, pages 57 and 58 | Search K94-36411 |
| Reset Switch with Product ID (item 7) | K94-36408-1 | Repair parts, pages 57 and 58 | Search K94-36408-1 |
| Batteries (2) with jumper (item 8) | K74-36596 | Repair parts, pages 57 and 58 | Browse batteries | Search K74-36596 |
| Toroidal Transformer (item 9) | LA500HDTKITSTD | Repair parts, pages 57 and 58 | Search LA500HDTKITSTD |
| Single Battery (item 10) | 29-NP712 | Repair parts, pages 57 and 58 | Browse batteries | Search 29-NP712 |
| Primary Arm (item 11) | LA500DC | Repair parts, pages 57 and 58 | Search LA500DC |
| Rear Connector with Pin (item 12) | KSWG-0623 | Repair parts, pages 57 and 58 | Search KSWG-0623 |
| Release Keys (item 13) | 41ASWG-0119 | Repair parts, pages 57 and 58 | Search 41ASWG-0119 |
| Steel Bracket Mounting Plates (item 14) | Q230 | Repair parts, pages 57 and 58 | Search Q230 |
| Bottom Washer and Nut (item 15) | Q232 | Repair parts, pages 57 and 58 | Search Q232 |
| Junction Box with Cable (item 16) | K94-36591 | Repair parts, pages 57 and 58 | Search K94-36591 |
Additional LA500UL parts listed by LiftMaster as "not shown" in the diagram (pages 57 and 58)
Swipe sideways to see all columns.
| Part (LiftMaster description) | LiftMaster part number | Find at All Security Equipment |
|---|---|---|
| Hardware Bag | K77-36389 | Search K77-36389 |
| Antenna | K77-36541 | Search K77-36541 |
| Standard Plastic Control Box (with control board) | LA500CONTUL | Search LA500CONTUL |
| J15 Harness | K94-36274-2 | Search K94-36274-2 |
| Wire harness between main control board and expansion board | K94-34778 | Search K94-34778 |
| Solar box for LA412U, LA400, LA500U | XLSOLARCONTUL | Search XLSOLARCONTUL |
| Large Metal Control Box Only | K74-39309-1 | Search K74-39309-1 |
| Large metal control box: Toroidal Transformer | LA500HDTKITXLM | Search LA500HDTKITXLM |
| Large metal control box: Outlet | K76-34771 | Search K76-34771 |
| Solar 33AH Battery Harness | K94-37236 | Search K94-37236 |
| 7AH Battery Harness | K94-36274-1 | Search K94-36274-1 |
| 33AH Battery Tray | K10-36183 | Search K10-36183 |
| Transformer | APOW3 | Search APOW3 |
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 57 to 58.
Compatible LA500UL Accessories
LiftMaster's manual lists the following accessories for the LA500UL (pages 61 and 62). Model numbers are LiftMaster's; the links go to related All Security Equipment categories and do not by themselves confirm that we stock an item or that it fits your operator.
Entrapment Protection Devices
LiftMaster monitored devices are required for UL 325 entrapment protection (see Install Entrapment Protection). Shop photoelectric sensors and edge sensors.
- LMTBUL, monitored through beam photoelectric sensor
- LMRRUL, monitored retro-reflective photoelectric sensor
- CPS-UN4 and CPSUN4G, LiftMaster Monitored Commercial Protector System
- LMWEKITU, monitored wireless edge kit (transmitter and receiver)
- LMWETXU, monitored wireless edge transmitter
- S50 (small profile monitored edge, 82 ft. roll) and S50E (small profile ends kit, 10 pair)
- L50CHAL, aluminum channel, 10 ft. (3.1 m), for both small and large edge profiles (pack of 8)
- L504AL, L505AL, L506AL (large profile monitored edges, 4, 5, 6 ft.)
Remote Controls and Access Devices
LiftMaster's remote controls are compatible with operators manufactured by LiftMaster after 1993. Shop gate remote controls and keypads.
- 893MAX, Security+ 2.0 3-button remote control (includes visor clip)
- 813LMX, Security+ 2.0 3-button open/close/stop programmable DIP remote control (ideal for applications to operate the gate with open, close, and stop functions assigned to separate buttons)
- 892LT and 894LT, Security+ 2.0 learning remote controls (one button can control a gate operator and the other(s) can control garage door(s))
- 878MAX, Security+ 2.0 keyless entry (4-digit code keypad)
- KPW250, wireless commercial keypad (Security+ 2.0 compatible)
- STAR1000, commercial access control receiver (up to 1,000 devices)
- 86LM, remote antenna extension kit
- LMSC1000, long range RFID reader
- CAPXLV2, CAPXM, and CAPXS, myQ Smart Video Intercom
- 828LM, LiftMaster Internet Gateway, which connects your gate operator to your WiFi network and allows you to monitor and control gate operators and lighting accessories enabled by myQ technology (ASE product page)
Operator Accessories
- LOOPDETLM, plug-in loop detector (low power; plugs into the existing control board; not to be used as entrapment protection). Search for LOOPDETLM or browse loop detectors.
- LD7LP, low power loop detector mounted and wired separately inside the control box (not to be used as entrapment protection)
- CP4, vehicle sensing probe
- MG1300, outdoor magnetic lock with transformer, junction box, mounting plate and hardware (not for use with solar applications; must be powered separately). Shop magnetic locks.
- APOW3, transformer
- K40-3505 and 40-39235-1, warning signs
- LA500CONTXLMUL, large metal control box (additional room in the control box; batteries not included) and XLSOLARCONTUL, large metal control box for solar applications
- SP10W12V (10 Watt, 12V) and SP20W12V (20 Watt, 12V), solar panels (see the solar requirements; this is a 24V system). Browse solar panels and accessories.
Batteries and Battery Hardware
- 29-NP712, standard 7AH 12 Vdc battery (reuse existing harnesses)
- A12330SGLPK, upgrade 33AH 12 Vdc battery (ideal for solar applications and extended battery backup; for use with the large metal control box and XLSOLARCONTUL boxes only)
- K10-36183, battery tray (required for 33AH applications)
- K94-37236, universal solar wire harness kit (for 7AH and 33AH applications). Search for K94-37236.
Two identical 12 Vdc batteries are required for each gate operator. Do not mix 7AH and 33AH batteries within a gate operator. Shop gate operator batteries.
Source: LiftMaster manual, 114-6272-000 Rev. A, pages 61 to 62.
Frequently Asked Questions About the LiftMaster LA500UL
What size gate can the LA500UL move?
Per the manual (page 7), the maximum gate weight depends on gate length: 1600 lbs. (725.7 kg) at 8 ft (2.4 m), 800 lbs. (362.9 kg) at 16 ft (4.9 m), and 600 lbs. (272.2 kg) at 18 ft (5.5 m). The 90 degree travel time is 15 to 18 seconds, the maximum travel range is 115 degrees, and the maximum daily cycle rate is 300 cycles per day. See Specifications.
How do I set the limits?
With the GATE switch on 1, press SET OPEN and SET CLOSE together to enter limit setting mode, move the gate with the MOVE GATE buttons and press SET OPEN or SET CLOSE at each limit, then cycle the gate with the TEST BUTTONS to set the force (page 23). Limits can also be set with a 3-button remote control, and LiftMaster recommends the Security+ 2.0 Model 813LMX for this (page 55). See Limit and Force Adjustment.
How do I open the gate by hand?
Insert the key, turn it 180° counter-clockwise, then turn the release lever 180° counter-clockwise. To engage again, turn the release lever and then the key 180° clockwise. Use the release only when the gate is not moving. See Manual Release.
What entrapment protection does the LA500UL need?
Per the manual, the operator has an inherent entrapment protection device built in, and the installer must provide one additional device for each entrapment zone. The operator will not run unless a minimum of one external device is connected in either the open or closed direction, and every entrapment zone must be protected (pages 3 and 18). See Install Entrapment Protection.
What batteries does the LA500UL use?
The standard control box comes with two 7AH batteries. LiftMaster says to use only part 29-NP712 for replacement batteries and recommends replacing them every 3 years. Solar installations use the large metal control box (XLSOLARCONTUL) with two 33AH batteries or the standard control box (LA500CONTUL) with two 7AH batteries. See Batteries and Solar Panels.
What wire gauge and length can I use?
See the maximum wire length table in Power Wiring (page 20): for example, 14 AWG up to 350 feet at 120 VAC and up to 1,150 feet at 240 VAC. Use copper conductors only.
What warranty does the LA500UL have?
Per the manual, LiftMaster's warranty is a 2 year limited warranty from the date of purchase. The warranty terms, including exclusions, are printed on page 63 of the manual.
Where is the wiring diagram?
The standard control box wiring diagram is on page 59 and the large metal control box wiring diagram is on page 60 of LiftMaster's installation manual. See the wiring diagram section.
Original LiftMaster LA500UL Documentation
This HTML resource is presented by All Security Equipment, is not a LiftMaster publication, and does not replace the original manufacturer documentation. It is based on LiftMaster's LA500UL installation manual, document 114-6272-000, Rev. A (© 2025 The Chamberlain Group LLC), which covers the LA500PKGUL, LA500DC, and LA500DCS.
- LiftMaster LA500PKGUL, LA500DC, LA500DCS Installation Manual, English (114-6272-000 Rev. A): the document this page is based on.
- LiftMaster LA500PKGUL single gate kit and LiftMaster LA500PKGUL dual gate kit at All Security Equipment, with the product literature.
Check the product page for the current revision before relying on any document, because LiftMaster may update them.
Related LiftMaster Resources
- LiftMaster LA500PKGUL single gate kit and dual gate kit at All Security Equipment
- Swing gate openers and operators and LiftMaster products
- Gate operator parts, gate operator accessories, and battery back-ups
- Gate operator articles and the Help Center
Other LiftMaster gate operator manuals on this site: LiftMaster CSL24UL instruction manual | LiftMaster RSL12UL instruction manual | LiftMaster HDSL24UL instruction manual | LiftMaster INSL24UL instruction manual | LiftMaster IHSL24UL instruction manual | LiftMaster SL3000UL instruction manual
Need the operator itself? All Security Equipment sells the LiftMaster LA500PKGUL light commercial / residential DC swing gate operator as a single gate kit and a dual gate kit.
This resource was last updated October 12, 2026. Based on LiftMaster document 114-6272-000 Rev. A.
