LiftMaster LA500 Installation Manual HTML Guide

This HTML resource is based on the LiftMaster LA500 installation manual for the LA500PKGUL single arm package, LA500DC primary 24 Vdc actuator arm, LA500DCS secondary 24 Vdc actuator arm (includes a monitored retro-reflective photoelectric sensor), and related LA500UL light commercial and residential DC vehicular swing gate operator applications.

The page is designed to make the manual easier to browse, search, and reference online while still linking to the original PDF for diagrams, exact manufacturer formatting, and official documentation.

Important: This product is intended to be installed and serviced by a trained gate systems technician only. Always follow the official LiftMaster manual, UL325 requirements, ASTM F2200 gate construction standards, local codes, and all safety instructions.

Compatible Models

  • LiftMaster LA500UL
  • LA500PKGUL Single Arm Package
  • LA500DC Primary 24 Vdc Actuator Arm
  • LA500DCS Secondary 24 Vdc Actuator Arm

Key Applications

  • Light commercial and residential vehicular swing gates
  • Class I, II, III, and IV vehicular swing gate applications
  • Single and dual swing gate setups (wired or wireless)
  • myQ, Security+ 2.0, and Security+ 3.0 MAX / Universal accessory compatible systems

Quick Specs

Specification Detail
Usage classification Class I, II, III, & IV
Main AC supply 120 Vac, 2 Amps (8 Amps including accessory outlets), or 240 Vac, 1 Amp
System operating voltage 24 Vdc transformer run / battery backup
Accessory power 24 Vdc, 500mA max. for ON + SW (switched)
Solar power max 24 Vdc at 60 watts max.
Maximum gate weight / length 1600 lbs / 8 ft, 800 lbs / 16 ft, 600 lbs / 18 ft
90 degree travel time 15 to 18 seconds
Maximum travel range 115 degrees
Maximum daily cycle rate 300 cycles per day
Maximum duty cycle Continuous
Operating temperature -40°C to 60°C (-40°F to 140°F)

Cover / Overview

Page 1: Cover and Product Overview
Page 1: Cover and Product Overview
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Vehicular Swing Gate Operator Installation Manual for Models LA500PKGUL, LA500DC, LA500DCS.

LIGHT COMMERCIAL - RESIDENTIAL DC

EXTERNAL SAFETY DEVICES REQUIRED. SEE SAFETY SECTION FOR UL 325 ENTRAPMENT PROTECTION REQUIREMENTS.

THIS PRODUCT MUST BE INSTALLED AND SERVICED IN ACCORDANCE WITH THIS MANUAL BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.

  • This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates.
  • This model is intended for use in Class I, II, III, and IV vehicular swing gate applications.
  • Visit LiftMaster.com to locate a professional installing dealer in your area.
  • This gate operator is compatible with myQ® and Security+ 2.0® accessories and Security+ 3.0® MAX and Universal accessories.

LiftMaster

300 Windsor Drive Oak Brook, IL 60523 LiftMaster Support Home

Safety

Page 2: Table of Contents and Safety Symbol Review
Page 2: Table of Contents and Safety Symbol Review
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Safety Symbol and Signal Word Review

When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully.

WARNING - Mechanical

WARNING - Electrical

CAUTION

IMPORTANT NOTE:

  • BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.
  • DO NOT attempt repair or service of your gate operator unless you are a Trained Gate Systems Technician.

WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

SAFETY

Page 3: Usage Class and UL325 Entrapment Protection Requirements
Page 3: Usage Class and UL325 Entrapment Protection Requirements
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Usage Class

Class I - Residential Vehicular Gate Operator. A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families.

Class II - Commercial/General Access Vehicular Gate. A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public.

Class III - Industrial/Limited Access Vehicular Gate. A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.

Class IV - Restricted Access Vehicular Gate Operator. A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.

UL325 Entrapment Protection Requirements

Definitions. ENTRAPMENT: The condition when a person is caught or held in a position that increases the risk of injury. SWING GATE ENTRAPMENT ZONE: Locations between a moving gate or moving, exposed operator components and a counter opposing edge or surface where entrapment is possible up to 1.8 m (6 ft.) above grade. Such locations occur if during any point in travel: a. The gap between the bottom of a moving gate and the ground is greater than 101.6 mm (4″) and less than 406 mm (16″); or b. The distance between the center line of the pivot and the end of the wall, pillar, or column to which it is mounted when in the open or closed position exceeds 101.6 mm (4″).

Requirements. A minimum of two independent monitored entrapment protection devices are required to be installed at each entrapment zone. It is the responsibility of the installer to install external monitored entrapment protection devices for each entrapment zone. The operator will only operate with a minimum of two independent monitored entrapment protection devices installed in either the open or closed direction. If no entrapment zone exists in the other direction, an external entrapment protection device is NOT required in that direction. This operator has an inherent entrapment protection device built-in. The installer MUST provide one additional entrapment protection device for each entrapment zone.

Acceptable entrapment protection device types include: inherent (built into the operator), LiftMaster monitored external photoelectric sensors, and LiftMaster monitored external edge sensors.

SAFETY

Page 4: Safety Installation Information
Page 4: Safety Installation Information
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of INJURY or DEATH: READ AND FOLLOW ALL INSTRUCTIONS. NEVER let children operate or play with gate controls. Keep the remote control away from children. ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. Use the manual release ONLY when the gate is not moving. KEEP GATES PROPERLY MAINTAINED. The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance. SAVE THESE INSTRUCTIONS.

Safety Installation Information

1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. 2. Gate operating system designers, installers, and users must take into account the possible hazards associated with each individual application. 3. A gate operator can create high levels of force in its function as a component part of a gate system. Specific safety features include: Edge Sensors (contact), Photoelectric Sensors, and Instructional and Precautionary Signage. 4. Install the gate operator only when the operator is appropriate for the construction and usage class of the gate, and all exposed pinch points are eliminated or guarded. 5. The gate operator is intended for installation only on gates used for vehicles; pedestrians must be supplied with a separate access opening located so persons will not come in contact with the vehicular gate. 6. The gate must be installed with enough clearance between the gate and adjacent structures to reduce the risk of entrapment. Swinging gates shall not open into public access areas. 7. The gate must work freely in both directions prior to installing the operator. 8. Permanently mounted access controls must be located at least 6 feet (1.8 m) away from any moving part of the gate. 9. Stop and/or Reset buttons must be located in the line-of-sight of the gate. 10. A minimum of two (2) WARNING SIGNS shall be installed so at least one is visible from each side of the gate. 11 and 12. Non-contact and contact sensor placement rules apply per UL 325, including a contact sensor on the bottom edge if that edge sits between 4 and 16 inches above grade at any point in its travel.

SAFETY

Page 5: Gate Construction Information
Page 5: Gate Construction Information
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Gate Construction Information

Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.

1.1 Gates shall be constructed per the provisions given for the appropriate gate type. 1.2 Gates shall not fall over more than 45 degrees from vertical when detached from supporting hardware. 1.3 Gates shall have smooth bottom edges, with protrusions not exceeding 0.50 inches (12.7 mm). 1.4 Minimum height for barbed tape is 8 feet above grade; barbed wire is 6 feet above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.8 Gates shall not move under gravity alone if the automatic operator is disconnected. 1.9 A separate pedestrian access shall be provided so pedestrians never contact the moving vehicular gate.

3.1.1.1 The width of an object (wall, pillar, or column) covered by a swing gate in the open position shall not exceed 4 inches (102 mm), measured from the pivot centerline, unless entrapment protection is added. 3.1.1.2 The distance between a fixed object and a swing gate in the open position shall not be less than 16 inches (406 mm), unless entrapment protection is added. 3.2 Class IV vehicular horizontal swing gates shall be designed per security parameters specific to the application.

SAFETY

Introduction

Page 6: Carton Inventory and Optional Accessories
Page 6: Carton Inventory and Optional Accessories
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Carton Inventory

NOT SHOWN: Documentation packet and hardware bag. Gate Operator, Standard Control Box with Batteries 12 Vdc 7AH (2), Key (2), Post Bracket, Gate Bracket, Warning Signs (2) and Warranty Card, Installation Manual. MODEL LA500DCS ONLY additionally includes: LiftMaster Monitored Retro-Reflective Photoelectric Sensor, Key (2), Gate Operator, Post Bracket, Gate Bracket, Junction Box, Terminal Block Connector, Watertight Extension Cable Connector.

Optional Accessories (not provided)

Large Metal Control Box (Model LA500CONTXLMUL). Ideal for installations that require additional room in the control box (batteries not included).

Large Metal Control Box for Solar Applications (Model XLSOLARCONTUL). Required for solar installations (batteries not included). Requires two 33AH batteries, battery tray, and solar battery harness, see Accessories.

INTRODUCTION

Page 7: Operator Specifications
Page 7: Operator Specifications
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Operator Specifications

Usage Classification: Class I, II, III, & IV. Main AC Supply: 120 Vac, 2 Amps (8 Amps including Accessory Outlets) OR 240 Vac, 1 Amp. System Operating Voltage: 24 Vdc Transformer Run / Battery Backup. Accessory Power: 24 Vdc, 500mA max. for ON + SW (switched). Solar Power Max: 24 Vdc at 60 watts max. Maximum Gate Weight/Length: 1600 lbs. (725.7kg) / 8 ft (2.4 m), 800 lbs. (362.9 kg) / 16 ft (4.9 m), 600 lbs. (272.2 kg) / 18 ft (5.5 m). 90 Degree Travel Time*: 15-18 seconds. Maximum Travel Range*: 115 degrees. Maximum Daily Cycle Rate: 300 cycles / day. Maximum Duty Cycle: Continuous. Operating Temperature: -40°C to 60°C (-40°F to 140°F). Expansion Board: Provided.

External Entrapment Protection Device Inputs (noncontact and/or contact): Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device. Expansion board - up to 3 entrapment protection devices configurable to either close or open direction and up to 8 edge sensors using wireless edge sensor kit models LMWEKITU and LMWETXU.

*Travel time and range are affected by A and B mounting dimensions, see INSTALLATION.

INTRODUCTION

Page 8: Site Preparation and Check Your Gate
Page 8: Site Preparation and Check Your Gate
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Site Preparation

Check the national and local building codes BEFORE installation. Refer also to the Site Planning Safety Checklist in the Appendix. Trench and install conduit. Before trenching, contact underground utility locating companies. Conduit must be UL approved for low and high voltage. Vehicle loops allow the gate to stay open when vehicles are obstructing the gate path, suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are not required but are recommended. Before installing your Access Control Device(s) be sure to complete a site survey and determine the best device for your site needs.

Entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application. Install a warning sign (two provided) on the inside and outside of the property, where easily visible. Gate must be constructed and installed according to ASTM F2200 standards and must fit specifications of the operator.

Check Your Gate

Gate MUST be level. Gate and gate post MUST be plumb. Gate MUST have a smooth bottom edge, no protrusions should exist. Remove ANY/ALL wheels from the bottom of gate. Gate MUST NOT hit or drag across ground. Gate MUST swing freely and be supported entirely by its hinges.

INTRODUCTION

Installation

Page 9: Installation Tips
Page 9: Installation Tips
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

CAUTION: To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep. ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.

Do's

Weld a horizontal bar across entire gate on any installation for strength. Make sure that the operator is mounted level or it will not function properly. Make sure there is slack in the operator cable. The operator can be mounted on top of the gate frame. The operator must be installed at least 12″ (30 cm) from the ground.

Don'ts

DO NOT install upside down. DO NOT install next to sprinklers or any area that may expose the bottom of operator to water. DO NOT install on uphill or downhill gates. DO NOT install on ANY pedestrian passageways, doorways, or gates. DO NOT over-bend the operator cable. DO NOT weld the crossbar on just a few pickets, or they could bend.

INSTALLATION

Page 10: Step 1 - Position the Brackets
Page 10: Step 1 - Position the Brackets
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Step 1 Position the Brackets

If this operator is a replacement for a Miracle-One™ operator, use the existing post bracket and gate bracket. If your application is Push-to-Open, refer to the illustrations in the Appendix. The measurements shown are typical for a standard installation.

1. Close the gate. 2. Choose a vertical mounting location for the post bracket. 3. Place a measuring tape under the center of the gate hinge point and measure out dimension A (see chart). 4. Mark the location of the first measurement. 5. Measure out dimension B from the previous mark. 6. Align the post bracket as close as possible above the mark and tack weld it in the desired vertical position. 7. Position a level on the post bracket and measure 35-1/2″ (90.2 cm) over from the center hole of the post bracket and mark the location on the gate. 8. Measure 2-1/4″ (6.4 cm) down from the previous mark and center the gate bracket on this mark, then tack weld it.

Dimension Chart (A / B)

7-3/4″ (19.7 cm) / 8-1/2″ (21.6 cm) — 8-1/2″ (21.6 cm) / 7-3/4″ (19.7 cm) — 9″ (22.9 cm) / 9″ (22.9 cm) — 9″ (22.9 cm) / 8-1/2″ (21.6 cm) — 7-1/2″ (19.1 cm) / 7-1/2″ (19.1 cm)

NOTES: There should only be a maximum of 4″ (10.2 cm) from the center of the hinge to the edge of the post or column; if greater, entrapment protection for this area is required. While the gate is in the fully open position, the operator needs a clearance of 11-1/4″ (28.6 cm). The ideal installation measurements are A = 7-3/4″ and B = 8-1/2″. If different measurements are used, the sum of A and B cannot be greater than 18″ (45.7 cm).

INSTALLATION

Page 11: Step 2 - Attach the Brackets
Page 11: Step 2 - Attach the Brackets
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Step 2 Attach the Brackets

1. Insert the key into the lock and turn it 180 degrees counterclockwise. Turn the release lever 180 degrees counterclockwise. The operator is now in manual mode. 2. Position the operator on the brackets and make sure the operator is level and positioned correctly on the gate. 3. Remove the operator from the gate. 4. Completely weld around the post bracket and gate bracket. NOTE: Brackets may need additional reinforcement by welding flat stock. 5. Attach the operator to the post bracket with the bolt, mounting plate, and nut. 6. Attach the gate bracket to the operator with the bolt, washer, and nut. Tighten the nut until it reaches the bottom of the gate bracket, then turn a half turn more, without overtightening. Make sure the trolley does not reach the fully open or fully closed position.

For dual gate applications, repeat the previous installation steps to install the second operator.

INSTALLATION

Page 12: Step 3 - Install the Control Box (Standard)
Page 12: Step 3 - Install the Control Box (Standard)
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Step 3 Install the Control Box - Standard Control Box

The control box MUST be mounted within 5 feet (1.52 m) of the gate operator. Mount the control box as high as possible for best radio reception. Make sure the control box is level. NOTE: The expansion board DOES NOT need to be removed for a wall or column mount installation.

1. Remove the screws and open the control box. 2. Disconnect the "Main Board" connector from the expansion board. 3. Remove the expansion board by removing the screws. 4. Select the mounting holes (according to your application) and remove the knockouts. 5. Secure the control box to the mounting surface: A. Wall or Column: Use the provided screws (4). B. Post: Use U-bolts and rubber washers (not provided) to ensure a watertight seal, keeping the U-bolts from protruding more than 3/4 inch (this can short the control board). 6. Reinstall the expansion board and connect the "Main Board" connector to the expansion board.

INSTALLATION

Page 13: Large Metal Control Box Installation
Page 13: Large Metal Control Box Installation
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Large Metal Control Box

The control box MUST be mounted within 5 feet (1.52 m) of the gate operator, as high as possible for best radio reception, and level. NOTE: The Large Metal Solar Control Box (Model XLSOLARCONTUL) does not have the electrical outlets or the expansion board.

Wall or Column Mount

1. Open the control box; the door may be removed by opening it 90 degrees. 2. Remove the toroid assembly by loosening the three screws and lifting it up and out. 3. Knock out the 4 corner holes. 4. Secure the control box to the mounting surface using the provided screws (4).

Post Mount

NOTE: The post mount option is not recommended for the 33AH battery application. 1. Open the control box. 2. Select center mounting holes (top and bottom) and knock out with a screwdriver and hammer to accommodate a 3/8″ diameter U-bolt. 3. Secure the control box with U-bolts and rubber washers (not provided) to ensure a watertight seal.

U-Bolt Opening: Standard 3″ Round Pipe = 3-1/2″, Standard 4″ Square Post = 4″, Standard 3″ Square Post = 6″.

INSTALLATION

Page 14: Step 4 - Earth Ground Rod and Step 5 - Wire the Operator Arm
Page 14: Step 4 - Earth Ground Rod and Step 5 - Wire the Operator Arm
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

WARNING: Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. ALL electrical connections MUST be made by a qualified individual. ALL power and control wiring MUST be run in separate conduit.

Step 4 Earth Ground Rod

Use the proper earth/ground rod for your local area. The ground wire must be a single, whole piece of wire, never spliced. 1. Install the earth/ground rod within 3 feet (.9 m) of the operator. 2. Run wire from the earth/ground rod to the control box. NOTE: If the operator is not grounded properly the range of the remote controls will be reduced and the operator will be more susceptible to lightning and surge damage.

Step 5 Wire the Operator Arm to the Control Board

1. Choose a knockout in the bottom of the control box. 2. Insert the operator cable through the provided watertight connector. 3. Insert the operator cable and watertight connector into the knockout. 4. Slide the connector nut onto the operator cable. 5. Connect the operator cable wires to the connector according to the colored label (white to white, red to red, etc.). 6. Plug the connector into the GATE 1 terminal on the control board. 7. Tighten the connector nut. If installing one operator, proceed to Step 7. If installing two operators, continue to Dual Gate Setup.

INSTALLATION

Page 15: Step 6 - Dual Gate Setup, Wireless Setup
Page 15: Step 6 - Dual Gate Setup, Wireless Setup
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Step 6 Dual Gate Setup

There are two options for dual gate communication: wired or wireless. Do not use wired and wireless communication simultaneously. Wired applications have a longer battery standby time than wireless applications. Wireless dual gates require two control boxes, one for each operator arm.

Wireless Setup

1. Choose an operator to be the network primary operator. 2. Press and release the LEARN button on the primary operator; the green XMITTER LED will light. NOTE: The operator will time out of programming mode after 180 seconds. 3. Press and release the LEARN button again; the yellow NETWORK LED will light. 4. Press and release the OPEN test button to assign this operator as network primary. 5-6. Repeat the LEARN button sequence on the second operator. 7. Press and release the CLOSE test button to assign this operator as network second. Both operators will beep and the yellow NETWORK LEDs will turn off, indicating success.

To deactivate: press LEARN once, then press LEARN again, then press and hold LEARN for 5 seconds until the NETWORK LED blinks and turns off. Repeat on the other operator.

INSTALLATION

Page 16: Wired Dual Gate Setup
Page 16: Wired Dual Gate Setup
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Wired Setup

Install a second operator arm, then install the extension cable and junction box. Before digging, contact local underground utility locating companies. 1. Trench across the driveway to bury the extension cable, using PVC conduit. 2. Open the junction box. 3. Select mounting holes and drill two holes large enough for the watertight connectors. 4. Mount the junction box within 3 feet (0.9 m) of the second operator. 5-7. Route the operator cable and extension cable through the watertight connectors into the junction box. 8. Connect the wires from the extension cable and operator cable to the terminal block connector (like-colored wires facing each other). 9-11. Secure the wires, tighten the connector nuts, and reinstall the cover.

INSTALLATION

Page 17: Wire Secondary Operator and Set the Bipart Delay
Page 17: Wire Secondary Operator and Set the Bipart Delay
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

1-7. Wire the secondary operator arm to the control board through a knockout, watertight connector, and the GATE 2 terminal, following the same colored-wire matching process as Gate 1.

Set the Bipart Delay (single control box)

Occasionally in dual gate installations, one gate needs to open first and close second, such as with an ornamental overhang or a solenoid lock. This is the Primary gate and connects to the GATE 1 terminal. The BIPART DELAY switch on the control board needs to be set to ON.

Set the Bipart Delay (dual control box)

BIPART DELAY: used where a mag-lock, solenoid lock, or decorative overlay requires one gate to close before the other. SYNCHRONIZED CLOSE: used where one gate travels a longer distance; set BIPART DELAY to ON for both control boxes to synchronize closing.

INSTALLATION

Page 18: Step 7 - Install Entrapment Protection
Page 18: Step 7 - Install Entrapment Protection
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

WARNING: ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone. Entrapment protection devices MUST be located to protect in BOTH the open and close gate cycles, between the moving gate and RIGID objects such as posts, walls, pillars, columns, or the operator itself.

Step 7 Install Entrapment Protection

1. Install entrapment protection devices for ALL entrapment zones. This operator has an inherent entrapment protection device built-in; the installer MUST provide one additional device per entrapment zone. 2. The operator will NOT run unless a minimum of one external device is connected in either the open or closed direction. If no entrapment zone exists in the other direction, an external device is NOT required there. 3. Test ALL entrapment protection devices AFTER installing the operator.

INSTALLATION

Page 19: Step 8 - Wire Entrapment Protection Devices
Page 19: Step 8 - Wire Entrapment Protection Devices
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

There are three options for wiring external entrapment protection devices. These inputs are for monitored devices only, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. Only one monitored device may be wired to each input; additional devices go on the expansion board.

Control Board Inputs

CLOSE EYES/INTERRUPT (2 Terminals): For photoelectric sensor entrapment protection in the close direction. An obstruction reopens the gate fully and resets the Timer-to-Close.

CLOSE EDGE (2 Terminals): For edge sensor protection in the close direction. An obstruction reverses the gate to full open, disengaging the Timer-to-Close.

OPEN EYES/EDGE (2 Terminals): For photoelectric or edge sensor protection in the open direction. An obstruction reverses the gate for 4 seconds then stops.

Expansion Board Inputs

EYE ONLY and COM: Open or close direction photoelectric sensors, functionality set by a nearby switch. EYE/EDGE and COM: Open or close direction photoelectric or edge sensors, functionality set by a nearby switch.

INSTALLATION

Page 20: Step 9 - Power Wiring (Standard Control Box)
Page 20: Step 9 - Power Wiring (Standard Control Box)
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Step 9 Power Wiring

The standard control box can be wired for either 120 Vac or 240 Vac; factory default is 120 Vac. Batteries are charged by the toroid transformer, plug-in transformer, or solar panels. Main power and control wiring MUST be run in separate conduits. Use copper conductors ONLY.

Standard Control Box Steps

1. Turn off AC power at the main breaker. 2. Run AC power wires to the control box. 3. Remove the toroid assembly by loosening the four screws. 4. Ensure the 120/240 plug is connected to the correct EMI board connector. 5. Connect the ground wire to the ground screw on the back of the toroid assembly. 6. Connect the white wire to NEUTRAL. 7. Connect the black wire to HOT. 8. Replace the toroid assembly. 9. Plug the J15 plug into the control board (a small spark is normal). 10. Turn ON AC power.

Wire Gauge Distance (120 Vac)

14 gauge: 350 ft (107 m). 12 gauge: 525 ft (160 m). 10 gauge: 850 ft (259 m). OR at 240 Vac: 14 gauge: 1,150 ft (351 m). 12 gauge: 1,850 ft (564 m). 10 gauge: 2,950 ft (899 m).

INSTALLATION

Page 21: Power Wiring (Large Metal Control Box)
Page 21: Power Wiring (Large Metal Control Box)
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

To use solar panels with the Large Metal Control Box (Model XLSOLARCONTUL), skip these steps and refer to Solar Panels in the Appendix.

1. Unplug the J15 plug labeled BATT(-)(+) DC(-)(+). 2. Turn off AC power at the breaker. 3-4. Run AC power wires and remove the toroid assembly (three screws). 5. Confirm the 120/240 plug setting. 6-8. Connect ground, neutral, and hot wires, then replace the toroid assembly. 9-12. Connect a jumper between one battery's positive terminal and the other's negative terminal, then connect the red J15 wire to the positive terminal and the black J15 wire to the negative terminal. 13. Plug the J15 plug into the control board. 14. Turn ON AC power.

All control wiring to Class 2 circuits must be Power-Limited Circuit Cable Type CL2, CL2P, CL2R, or CL2X or better.

INSTALLATION

Page 22: Step 10 - Install Warning Signs and Step 11 - Finish the Installation
Page 22: Step 10 - Install Warning Signs and Step 11 - Finish the Installation
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Step 10 Install Warning Signs

Installers MUST install the UL required warning signs in plain view on both sides of each gate installed. Use the fastening holes in each corner to permanently secure the sign.

Step 11 Finish the Installation

1. Turn the release lever clockwise 180 degrees back to the engaged position; this engages the motor. 2. Turn the key clockwise 180 degrees; this locks the release lever. The operator is now engaged.

INSTALLATION

Adjustment

Page 23: Limit and Force Adjustment
Page 23: Limit and Force Adjustment
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

WARNING: Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate. NEVER increase force beyond the minimum amount required to move the gate. NEVER use force adjustments to compensate for a binding or sticking gate. After ANY adjustments are made, the safety reversal system MUST be tested.

Introduction

The electronic controls sense the amount of force required to open and close the gate. Force is adjusted automatically when you program the limits but should be fine-tuned using the REVERSAL FORCE dial to compensate for environmental changes. The limits can be set using the control board or a remote control (a 3-button remote programmed to OPEN, CLOSE, and STOP).

Limit Setup LEDs

SET OPEN off / SET CLOSE off = Normal Mode, limits are set. Both blinking = Limit Setting Mode, limits are not set. SET OPEN blinking / SET CLOSE on = open limit not set. SET OPEN on / SET CLOSE blinking = close limit not set. Both on = Limit Setting Mode, limits are set.

ADJUSTMENT

Page 24: Initial Limits and Force Adjustments
Page 24: Initial Limits and Force Adjustments
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

For dual gate applications the limits must be set for each operator. The gate MUST be attached to the operator before setting limits and force. If a mistake is made, press the reset button to start over.

1. Set the GATE switch to the 1 position. 2. Press and release SET OPEN and SET CLOSE simultaneously to enter limit setting mode. 3. Press and hold the MOVE GATE buttons to move the gate to the open or close limit. 4. Press and release SET CLOSE or SET OPEN depending on which limit is being set. 5-6. Repeat for the other limit; the operator exits limit setting mode. 7. Cycle the gate open and close using the TEST BUTTONS; this automatically sets the force. 8. For dual gates, set the GATE switch to position 2 and repeat steps 2-7.

ADJUSTMENT

Page 25: Fine Tune the Force and Obstruction Test
Page 25: Fine Tune the Force and Obstruction Test
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Fine Tune the Force

The REVERSAL FORCE DIAL is set to minimum at the factory. The force setting should be high enough that the gate will not reverse by itself or cause nuisance interruptions, but low enough to prevent serious injury. 1. Open and close the gate with the TEST BUTTONS. 2. If the gate stops or reverses before reaching a limit, increase force by turning the dial slightly clockwise. 3. Perform the Obstruction Test after every adjustment.

Obstruction Test

1. Open and close the gate with the TEST BUTTONS, confirming it stops at the proper limits. 2. Place an object between the open gate and the fixed closed catch post, or obstruct by hand, without triggering external entrapment devices. 3. Run the gate in the close direction; it should stop and reverse on contact. If it does not reverse, reduce force slightly counterclockwise. 4. Repeat the test for the open direction.

ADJUSTMENT

Programming

Page 26: Remote Controls (Security+ 2.0)
Page 26: Remote Controls (Security+ 2.0)
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

A total of 50 Security+ 2.0® remote controls or KPW250 keypads and 2 keyless entries can be programmed to the operator. NOTE: If installing an 86LM to extend range, DO NOT straighten the antenna.

Programming Options

Single button as OPEN only: Press LEARN (XMITTER LED lights, 30 second timeout), press OPEN, then press the remote button to program.

Single button (SBC) as OPEN, CLOSE, and STOP: Press LEARN, then press the remote button to program.

Three separate buttons as OPEN, CLOSE, and STOP: Press LEARN, press OPEN/CLOSE/STOP depending on function, then press the corresponding remote button.

The operator exits learn mode automatically (beeps, XMITTER LED off) if programming succeeds. Repeat for additional remotes.

PROGRAMMING

Page 27: Programming Security+ 3.0 MAX Remote Controls
Page 27: Programming Security+ 3.0 MAX Remote Controls
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

CAUTION: The gate will move during programming and verification. Ensure the area is clear of people, vehicles, and obstructions. Compatible MAX remotes: 1-Button (CH361), 2-Button (L932M, CH382), 3-Button (L993M).

Step 1: Put the Remote into Programming Mode

1-Button remote: press and release 6 times within 4 seconds until the red LED turns solid. 2-Button remote: press and hold both buttons about 6 seconds until the LED turns solid. 3-Button remote: press and hold the two smaller buttons about 6 seconds until the LED turns solid.

Step 2: Program to the Gate Operator

1. Press and release LEARN on the operator (green XMITTER LED lights). 2. On the remote, press the desired button twice in quick succession. 3. The remote transmits; the LEARN LED flashes once then turns off, confirming recognition. 4. When the gate begins to move, immediately press and release any remote button to complete programming.

Step 3: Verify Programming

Confirm the LEARN LED is off, then press the programmed remote button and confirm the gate moves.

PROGRAMMING

Page 28: Security+ 3.0 Keypads and LiftMaster Internet Gateway
Page 28: Security+ 3.0 Keypads and LiftMaster Internet Gateway
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Instructions for programming Security+ 3.0 keypads and/or universal remote controls are located on the LiftMaster support site.

LiftMaster Internet Gateway (Not Provided)

1. Connect the ethernet cable to the LiftMaster Internet Gateway and router. 2. Connect power to the Gateway. 3. Download the myQ® App. 4. Set up an account and add your gate operator. 5. The Gateway will pair to the operator if within range; the operator beeps if successful. The gate operator can then be controlled through the myQ® App.

CAPXL/CAPXLV Connected Access Portal

The CAPXL/CAPXLV communicates wirelessly to LiftMaster gate operators to send open commands, monitor gate position, and send email notifications. Up to 8 operators can be paired with the CAPXL/CAPXLV.

PROGRAMMING

Page 29: Erase Codes, Erase Limits, CPO, and Remove Devices
Page 29: Erase Codes, Erase Limits, CPO, and Remove Devices
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Erase All Codes

1. Press and release LEARN (XMITTER LED lights). 2. Press and hold LEARN again until the LED flashes, then release (about 6 seconds). All remote codes are erased.

Erase Limits

1. Press and hold SET OPEN and SET CLOSE simultaneously (5 seconds) until both LEDs blink rapidly and the operator beeps. 2. Release; the LEDs blink slowly, indicating limits need to be set.

Constant Pressure Override (CPO)

CPO is for use with KPW5 and KPW250 keypads. It temporarily overrides a fault in the entrapment protection system, for use only in line of sight of the gate with no obstructions. 1. Enter a valid 4-digit PIN. 2. Press and hold # for 5 seconds to enter CPO; continue holding to keep the operator in motion. 3. The operator stops at a limit or when # is released.

To Remove and Erase Monitored Entrapment Protection Devices

1. Remove the device wires from the terminal block. 2. Press and release SET OPEN and SET CLOSE simultaneously; both LEDs turn on. 3. Press and release both buttons again to exit learn limit mode.

PROGRAMMING

Operation

Page 30: Gate Operator Setup Examples
Page 30: Gate Operator Setup Examples
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Setup examples cover four site types: Residential (1 to 4 homes), Commercial/General Access (shared community entrance), Commercial (security-focused business site), and Industrial (large business site requiring security). Each site type has recommended settings for Quick Close, AC Fail Open, Low Battery behavior, Anti-Tail, Bipart Delay, and Auxiliary Relay outputs (open limit indicator, close limit indicator, gate motion alert, pre-motion delay alert, power status, and cycle count feedback for servicing).

OPERATION

Page 31: Control Board Overview
Page 31: Control Board Overview
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

SET OPEN / SET CLOSE Buttons: set the OPEN/CLOSE limits. MOVE GATE Buttons: open or close the gate in Limit setting mode. BATT FAIL switch: controls gate behavior when battery voltage is critically low (under 23 V). BIPART DELAY Switch: used only for dual gates. LEARN Button: programs remote controls and the wireless network. TIMER-TO-CLOSE dial: automatically closes the gate after 0 to 180 seconds (0 is off). REVERSAL FORCE dial: fine-tunes force. TEST BUTTONS: operate OPEN, STOP, and CLOSE. STATUS LEDs: indicate operator status. DIAGNOSTICS Display: shows operator type ("LA50" for LA500UL), firmware version, and diagnostic codes.

OPERATION

Page 32: Manual Release, Reset Button, and Party Mode
Page 32: Manual Release, Reset Button, and Party Mode
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Manual Release

In case of a power failure, the operator can be disengaged from the gate. NOTE: It is normal for the operator to run slow right after a disconnect or complete loss of power. Release: insert the key, turn it counterclockwise 180 degrees, then turn the release lever counterclockwise 180 degrees. Engage: turn the release lever clockwise 180 degrees, then turn the key clockwise 180 degrees, then remove and store the key.

Reset Button

Located on the side of the control box. Stops a moving gate like a stop button, disables the Timer-to-Close while the gate is open, and shuts off the alarm to reset the operator.

Party Mode

Press the reset button once while the gate is open to disable the Timer-to-Close; the gate stays open until the reset button is pressed again or a programmed remote is activated. Can also be enabled from a KPW5 or KPW250 keypad using a valid 4-digit PIN. NOTE: Using Party Mode at a solar site will deplete the batteries.

OPERATION

Page 33: Operator Alarm and Remote Control
Page 33: Operator Alarm and Remote Control
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Operator Alarm

When the inherent force of the operator detects the following twice consecutively, the alarm will sound up to 5 minutes and the operator will need to be reset: the gate hitting an obstruction, the arm or gate being incorrectly installed, the gate not meeting specifications, hinges too tight or broken, a car pushing the gate, a foreign object on the gate frame, or the gate hitting the driveway/curb and getting stuck. Remove obstructions and press the reset button to shut off the alarm. The alarm will beep 3 times with a command if the battery is low.

Remote Control (Single Button Control)

When the gate is closed, activating the remote opens it; a second activation during the open cycle stops the gate; a third activation closes it. When the gate is open, activation closes it; if activated while closing, the gate stops and the next activation reopens it.

OPERATION

Accessory Wiring

Page 34: External Control Devices
Page 34: External Control Devices
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

All control wiring to Class 2 circuits must be Power-Limited Circuit Cable Type CL2, CL2P, CL2R, or CL2X or better. NOT TO BE USED AS ENTRAPMENT PROTECTION.

EXIT (2 Terminals): A soft open command for exit probes, telephone entry, external exit loop detectors, or any device commanding the gate to open. Opens a closed/closing gate; holds an open gate open if maintained.

SHADOW (2 Terminals): For a shadow loop detector positioned under the swing of the gate. Holds the gate open at the limit; only active at the OPEN limit.

INTERRUPT (2 Terminals): For an interrupt loop detector on the outside of the gate. Holds the gate open at the limit, stops and reverses a closing gate, and activates quick close/anti-tailgate features when enabled on the expansion board.

ACCESSORY WIRING

Page 35: Maglock and Miscellaneous Wiring
Page 35: Maglock and Miscellaneous Wiring
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Maglock (LOCK, 2 Terminals, N.C. and COM)

Relay contact output, normally-closed for maglocks. The relay activates prior to and during motor run, and turns off when the motor is off.

Miscellaneous Wiring

Single Button Control (SBC) (2 Terminals): Gate command sequence Open, Stop, Close, Stop. Fire Department Open Input (2 Terminals): Acts as a hard open; a maintained input overrides external safeties and re-enables the Timer-to-Close. Accessory Power 24 Vdc, max 500 mA (4 Terminals): Switched (on during motion and open-limit timer, off 5 seconds after motion) or Unswitched (always on).

ACCESSORY WIRING

Expansion Board

Page 36: Expansion Board Overview
Page 36: Expansion Board Overview
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

CAUTION: To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.

QUICK CLOSE switch: when ON, deactivating the CLOSE EYES/Interrupt loop causes an opening or stopped gate to close, ignoring the Timer-to-Close. AC FAIL switch: OPEN causes the gate to open on AC power loss and stay open; BATT keeps the gate in place, running on batteries. EXIT FAIL switch: controls behavior when the plug-in EXIT loop detector faults. ANTI-TAIL switch: OFF reverses a closing gate on interrupt activation; ON pauses the closing gate instead. AUX RELAY switches and EYE/EDGE switches configure auxiliary relay behavior and sensor direction. Also includes the 1/2/3 LEDs for input status and firmware version display, the MAIN BOARD input connector, loop detector inputs, and the wireless edge input.

EXPANSION BOARD

Page 37: Auxiliary Relays 1 and 2
Page 37: Auxiliary Relays 1 and 2
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Normally Open (N.O.) and Normally Closed (N.C.) relay contacts for external devices, Class 2 low voltage (42 Vdc / 34 Vac max, 5 Amps). Function is set by three dipswitches per relay: Off (always off, conserves battery), Open Limit Switch (energizes at open limit, use with SAMS), Close Limit Switch (energizes when not at close limit), Gate Motion (energizes when motor runs), Pre-Motion Delay (energizes 3 seconds before motion), Power (energizes when AC/solar power is present, or on battery power for relay 2), Tamper (energizes if the gate is manually pushed off the close limit), and Cycle Quantity Feedback (blinks out the total cycle count on relay 1 only).

EXPANSION BOARD

Page 38: Red/Green Light Functionality and Auxiliary Relay Wiring
Page 38: Red/Green Light Functionality and Auxiliary Relay Wiring
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

A red light wired to AUX RELAY 1 and a green light wired to AUX RELAY 2 can indicate gate state: closed (red off, green off), opening/closing (red on/flashing, green off), open (red off, green on), and various timer states. Auxiliary relay wiring requires a Class 2 power source rated 42 Vdc (34 Vac) max, 5 Amps, connected to the warning light's N.C., COM, and N.O. terminals as needed.

EXPANSION BOARD

Page 39: Wiring Accessories to the Expansion Board
Page 39: Wiring Accessories to the Expansion Board
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

The expansion board provides inputs for: wireless edge receivers; EYES ONLY and EYES/EDGE entrapment protection devices (direction set by nearby switches); Single Button Control; a 3-Button Control Station (Open, Close, Stop with common); an Exit Loop Input; a Shadow Loop Input; and an Interrupt Loop Input. Each loop input behaves the same way as its main-board counterpart described in Accessory Wiring.

EXPANSION BOARD

Maintenance

Page 40: Maintenance Chart and Batteries
Page 40: Maintenance Chart and Batteries
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

WARNING: ALL maintenance MUST be performed by a Trained Gate Systems Technician. Disconnect all power (AC, solar, battery) before servicing; the AC Power switch ONLY turns off AC power and does NOT turn off battery power. ALWAYS disconnect the batteries to service the operator. To reduce the risk of FIRE or INJURY, use ONLY LiftMaster part 29-NP712 for replacement batteries.

Description / Task Monthly 6 Months 3 Years
Entrapment protection devices – check and test X
Warning signs – confirm present, replace if worn X
Manual disconnect – check and test X
Gate – inspect for wear/damage, ASTM F2200 compliance X
Accessories – check for proper operation X
Electrical – inspect wire connections X
Mounting hardware – check for tightness X
Operator – inspect for wear/damage X
Batteries – replace X

Batteries degrade over time depending on temperature and usage; the alarm beeps 3 times with a command if the battery is low. Replace every 3 years using only LiftMaster part 29-NP712. The standard control box uses two 7AH batteries; a Large Metal Control Box solar installation may use two 33AH batteries (A12330SGLPK) with a battery tray (K10-36183) and harness (K94-37236).

MAINTENANCE

Troubleshooting

Page 41: Diagnostic Codes
Page 41: Diagnostic Codes
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

To view codes: press and hold STOP, then CLOSE, then OPEN until "Er" shows on the display. The operator shows the code sequence number (01 is most recent) followed by the code itself. Press OPEN to scroll to the most recent code; press CLOSE to scroll to the oldest (up to 20 saved). Press and release STOP to exit; the display also times out after two minutes. To reset the code history, press and hold STOP for six seconds until "Er" then "CL" alternate, then release.

TROUBLESHOOTING

Page 42: Control Board LEDs
Page 42: Control Board LEDs
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Status LEDs: INPUT POWER (on when AC/solar available), BATT CHARGING (on during three-stage charging), TIMER (off/on/blinking states show timer running, paused, or canceled), GATE MOVING (on when opening/closing; blink patterns indicate single or double entrapment), BATT LOW (on = low, blinking = critically low), ACC PWR OVLD (on = accessory overload tripped).

Input LEDs: SBC, FIRE DEPT, EXIT, SHADOW, CLOSE EYES/INTERRUPT, CLOSE EDGE, and OPEN EYES/EDGE each show off (inactive), on (active), or blinking (active on the other operator or expansion board). LOCK LED shows whether the maglock relay is active.

TROUBLESHOOTING

Page 43: Troubleshooting Chart
Page 43: Troubleshooting Chart
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.
Symptom Possible Causes Solutions
Operator does not run, diagnostic display off No power to control board, open fuse, low/dead batteries, inoperable control board Check AC and battery power, check fuses, charge or replace batteries, replace control board if needed
Control board powers up but motor does not run Stuck reset switch, active stop input, low batteries, active open/close input, entrapment device active, vehicle loop active Check the reset switch and stop button, charge or replace batteries, check all inputs for a stuck-on signal
Arm moves but cannot set correct limits Arm not extending/retracting enough, arm interfering with bracket, gate too difficult to move Disengage and check arm movement, examine hinge/bracket clearance, repair the gate so it moves freely limit to limit
Gate does not fully open or close when setting limits Same as above Same as above
Operator does not respond to a wired control Stuck input, active stop button, stuck reset, low batteries, active entrapment device or loop detector Check inputs, stop button, reset button, batteries, and sensors for a stuck-on condition
Operator does not respond to a wireless control Remote not learned, stop button active, stuck reset, poor radio reception Re-learn the remote, check the stop and reset buttons, check the antenna and wiring

TROUBLESHOOTING

Page 44: Troubleshooting Chart Continued
Page 44: Troubleshooting Chart Continued
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.
Symptom Possible Causes Solutions
Gate stops during travel and reverses immediately Active control input, active loop detector, low battery voltage, entrapment protection activated Check inputs, confirm battery voltage is 23.0 Vdc or higher, clear obstructions and retest
Gate opens but will not close Open control active, loop detector active, Fire Dept input active, TTC not set, close entrapment device active Check all listed inputs and the Timer-to-Close setting
Gate closes but will not open Vehicle loop detector active, low battery with LOW BATT set to CLOSE Check loop detector inputs, charge or replace batteries
Exit loop activation does not open the gate Detector setup incorrect, inoperable detector, low battery Review loop settings, replace detector, charge/replace batteries
Interrupt loop does not stop/reverse the gate Detector setup incorrect or inoperable Review settings, replace detector
Shadow loop does not hold the gate open Detector setup incorrect or inoperable Review settings, replace detector

TROUBLESHOOTING

Page 45: Troubleshooting Chart Continued
Page 45: Troubleshooting Chart Continued
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.
Symptom Possible Causes Solutions
Obstruction in the gate's path does not cause a reversal Force adjustment needed Perform the obstruction test and adjust force per the Adjustment section
Photoelectric or edge sensor does not stop/reverse the gate Incorrect wiring or inoperable sensor Check wiring, retest, replace the sensor if faulty
Alarm sounds for 5 minutes or with a command Double entrapment detected Clear the obstruction, press reset to silence the alarm
Alarm beeps three times with a command Low battery Check AC power, charge or replace batteries
Incorrect gate opens/closes first on a dual-gate system Incorrect Bipart switch setting Set Bipart switch ON on the operator that opens second and OFF on the operator that opens first
Maglock or solenoid lock not working correctly Lock wired incorrectly or unpowered Confirm lock is wired to the correct N.C./N.O. and COM terminals and powered separately, not from accessory power
Solar operator not getting enough cycles per day Insufficient panel wattage, excessive accessory draw, old batteries, insufficient sunlight Add panels, reduce accessory load, replace batteries, or relocate panels away from obstructions

TROUBLESHOOTING

Page 46 to 47: Diagnostic Codes Table
Page 46 to 47: Diagnostic Codes Table
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.
Code Meaning Solution
31 Main control board internal error Disconnect all power for 15 seconds, then reconnect. Replace board if it continues.
32 / 33 Linear drive disengaged (Arm 1 / Arm 2) Disengage then re-engage the arm; check wiring and connections
35 Max-run-time exceeded Check for an obstruction, then reprogram the limits
36 / 37 Product ID error / failure Erase limits and reset if board was replaced, or reseat the product ID harness
38 / 39 Hard stop limit (Arm 1 / Arm 2) Re-adjust the limit or the mounting
40 / 41 Battery overvoltage / overcurrent Check the harness; confirm correct battery voltage for the system
42 No battery at boot up Check battery connections; replace if depleted below 20V (24V system) or 10V (12V system)
43 / 44 / 45 Exit / Shadow / Interrupt loop error Check loop wiring for a short or open connection
46 Wireless edge battery low Replace batteries in the wireless edge
60 Minimum entrapment protection devices not installed Review entrapment protection connections; at least one external device is required
61-66 Entrapment input held more than 3 minutes (main or expansion board) Check wiring, alignment, and obstruction on the relevant input
91-94 Force or RPM/stall reversal (Operator 1 / 2) Check for obstruction; confirm mechanical assembly is engaged and free to move
99 Normal operation No action required

TROUBLESHOOTING

Appendix

Page 48: Installation Types
Page 48: Installation Types
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Covers Pull-to-Open and Push-to-Open configurations for both column and post installations, with reinforcement steel plate guidance for each, and a note to weld rebar behind gate hinges for maximum strength.

APPENDIX

Page 49: Step 1 - Position the Brackets (Push-to-Open)
Page 49: Step 1 - Position the Brackets (Push-to-Open)
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

For Push-to-Open applications, a hole schedule and reinforcement plate (fabricated on site) locates the brackets 35-1/2″ (90.2 cm) apart with additional hole spacing of 7-3/4″ and 8-1/2″ as shown in the dimension chart.

APPENDIX

Page 50: Step 8 - Solar Panels
Page 50: Step 8 - Solar Panels
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

SOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES.

33AH Battery Requirements

Large Metal Control Box for Solar Applications (XLSOLARCONTUL), a minimum of two and maximum of six 10W solar panels (SP10W12V), two 33AH batteries (A12330SGLPK), solar battery harness (K94-37236), and battery tray (K10-36183).

7AH Battery Requirements

Standard Control Box for Solar Applications (LA500CONTUL), the same solar panel range, two 7AH batteries (29-NP712), and solar battery harness (K94-37236).

Solar Zones

Zone 1 (6 hours sunlight/day) is ideal for solar; Zone 2 (4 hours) is recommended; Zone 3 (2 hours) success depends on operator type and panel placement. Solar installations are not supported in northern climates or areas with heavy fog, lake effect snow, or rain.

APPENDIX

Page 51: Solar Usage Guide
Page 51: Solar Usage Guide
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Typical standby battery current draw at 24V: main board with no radios, 2.7 mA; each LiftMaster remote programmed, +1 mA; myQ device or wireless dual gate, +2.4 mA; expansion board, +11.1 mA; each plug-in loop detector, +3.8 mA (up to 3 supported). NOTE: photoelectric sensor heaters (LMRRUL, LMTBUL) are not recommended in solar applications.

Cycles per day scale with solar zone, panel wattage (10W to 60W), and battery size (7AH or 33AH). A 60W panel with 33AH batteries in Zone 1 supports up to roughly 300 cycles per day for a single gate; the same setup in Zone 3 drops to as low as 24 to 39 cycles per day. All figures are estimates; actual results vary by gate construction, installation, and temperature.

APPENDIX

Page 53 to 54: Solar Panel Position, Installation, and Wiring
Page 53 to 54: Solar Panel Position, Installation, and Wiring
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Solar panels must be mounted facing due south (verify with a compass), clear of shade from buildings and trees for a 180-degree arc east to west. If the panel is not casting a shadow, the battery is not charging. To optimize for winter, tilt the panel up to 15 degrees more vertical. Installation: position the mounting bracket, secure the panel to the bracket with the provided hardware, then secure the bracket to the mounting surface with lag screws.

The Solar Harness Kit (K94-37236) wires the batteries and solar panels. 33AH batteries wire in series with red, black, and a white jumper wire; 7AH batteries follow the same series wiring pattern. Solar panels wire in series for 20W, 40W, and 60W configurations depending on the number of panels used.

APPENDIX

Page 55: Limit Setup with a Remote Control
Page 55: Limit Setup with a Remote Control
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Requires a 3-button remote programmed for OPEN, CLOSE, and STOP (Security+ 2.0 Model 813LMX recommended; SP3 remotes are not recommended for this task). With the gate closed, press SET OPEN and SET CLOSE together to enter limit setting mode, jog the gate to the desired open position using the remote, press STOP to confirm, then press OPEN again to set that limit. Repeat the process using CLOSE and STOP to set the close limit. Cycling the gate afterward sets the force automatically.

APPENDIX

Page 56: SAMS Wiring with the Relays Not Energized
Page 56: SAMS Wiring with the Relays Not Energized
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

The Sequenced Access Management System (SAMS) uses programmable relays to determine the order in which multiple control devices operate across an opening, such as a swing gate opening fully before a barrier arm activates. This wires the barrier arm operator's auxiliary command input to the Exit Input on one control board and the Shadow Input on the expansion board of the other, with AUX Relay 1 dipswitches set to 1-OFF, 2-OFF, 3-ON.

APPENDIX

Repair Parts

Page 57 to 58: Repair Parts
Page 57 to 58: Repair Parts
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Standard Control Box

Item Part Number Description
1 K74-39307-1 Standard Plastic Control Box Only
2 K76-36296-1 Outlet
3 K75-36635 Control Board Bracket
4 K1D8388-1CC Control Board
5 K1D8387-1CC Expansion Board
6 K94-36411 Piezo Alarm
7 K94-36408-1 Reset Switch with Product ID
8 K74-36596 Batteries (2) with jumper
9 LA500HDTKITSTD Toroidal Transformer
10 29-NP712 Single Battery

Large Metal Control Box

Large Metal Control Box Only (K74-39309-1), Toroidal Transformer (LA500HDTKITXLM), Outlet (K76-34771), Solar 33AH Battery Harness (K94-37236), 7AH Battery Harness (K94-36274-1), 33AH Battery Tray (K10-36183), Transformer (APOW3).

Gate Operator Arm

Primary Arm (LA500DC), Rear Connector with Pin (KSWG-0623), Release Keys (41ASWG-0119), Steel Bracket Mounting Plates (Q230), Bottom Washer and Nut (Q232), Junction Box with Cable (K94-36591).

REPAIR PARTS

Wiring Diagram

Page 59: Wiring Diagram - Standard Control Box
Page 59: Wiring Diagram - Standard Control Box
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

WARNING: To protect against fire and electrocution, DISCONNECT power (AC or solar and battery) BEFORE installing or servicing the operator. Replace fuses ONLY with a fuse of the same type and rating.

The standard control box wiring diagram maps the EMI filter/surge protection board, transformer run kit, battery connections, expansion board, reset switch, piezo alarm, photoelectric sensor and edge sensor terminals, hard-wired open/close/stop and exit inputs, loop detector wiring, antenna connection, and earth ground rod connection.

WIRING DIAGRAM

Page 60: Wiring Diagram - Large Metal Control Box
Page 60: Wiring Diagram - Large Metal Control Box
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

The Large Metal Control Box wiring diagram follows the same layout as the standard box, with the input power connection shown both with and without the optional transformer run kit, and includes wiring for the primary and secondary operator terminals.

WIRING DIAGRAM

Accessories

Page 61: Entrapment Protection and Remote Controls
Page 61: Entrapment Protection and Remote Controls
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Entrapment Protection

LiftMaster monitored through-beam photoelectric sensor (Model LMTBUL). LiftMaster monitored retro-reflective photoelectric sensor (Model LMRRUL). LiftMaster Monitored Commercial Protector System® (Models CPS-UN4 and CPSUN4G). LiftMaster monitored wireless edge kit transmitter and receiver (Model LMWEKITU). LiftMaster monitored wireless edge transmitter (Model LMWETXU). Aluminum channel, 10 ft, for small and large edge profiles (Model L50CHAL). LiftMaster large profile monitored edges, 4/5/6 ft (Models L504AL, L505AL, L506AL). Small profile monitored edge, 82 ft roll (Model S50) with ends kit (Model S50E).

Remote Controls

Security+ 2.0® 3-button remote (Model 893MAX). Security+ 2.0® learning remotes (Models 892LT and 894LT). Security+ 2.0® keyless entry (Model 878MAX). Security+ 2.0® 3-button open/close/stop programmable DIP remote (Model 813LMX).

ACCESSORIES

Page 62: Miscellaneous Accessories and Batteries
Page 62: Miscellaneous Accessories and Batteries
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

Remote antenna extension kit (Model 86LM). Commercial access control receiver, up to 1,000 devices (Model STAR1000). Plug-in loop detector, not for entrapment protection (Model LOOPDETLM). Low power loop detector (Model LD7LP). Vehicle sensing probe (Model CP4). Magnetic gate lock, not for solar applications (Model MG1300). Transformer (Model APOW3). Wireless commercial keypad, Security+ 2.0® compatible (Model KPW250). myQ® Smart Video Intercom (Models CAPXLV2, CAPXM, CAPXS). LiftMaster® Internet Gateway (Model 828LM). Long range RFID reader (Model LMSC1000).

Batteries

Two identical 12 Vdc batteries are required per operator; do not mix 7AH and 33AH batteries in the same operator. 7AH battery, 12 Vdc, replacement (Model 29-NP712). 33AH battery, 12 Vdc, for solar and extended backup, Large Metal Control Box and XLSOLARCONTUL only (Model A12330SGLPK). Battery tray for 33AH applications (Model K10-36183). Universal solar wire harness kit for 7AH and 33AH applications (Model K94-37236).

ACCESSORIES

Warranty

Page 63: LiftMaster 2 Year Limited Warranty
Page 63: LiftMaster 2 Year Limited Warranty
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

LiftMaster warrants to the first purchaser of this product, for the structure in which it is originally installed, that it is free from defect in materials and/or workmanship for 2 years from the date of purchase. Proper operation depends on compliance with the installation, operation, maintenance, and testing instructions in this manual; failure to comply voids this warranty entirely.

Call 1-800-528-2806 before dismantling the product if a defect appears during the warranty period. Include a brief description of the problem and a dated proof-of-purchase receipt with any returned product.

This warranty does NOT cover non-defect damage, damage from improper installation or care, labor for reinstalling a repaired unit, or battery replacement. It also does NOT cover problems with the gate or gate hardware (springs, rollers, alignment, hinges) or problems caused by interference. Seller liability under this warranty is limited to the cost of the product.

WARRANTY

Safety Checklist

Page 64 to 65: Swing and Slide Gate Operator Safety Checklist
Page 64 to 65: Swing and Slide Gate Operator Safety Checklist
For images, wiring diagrams, mounting illustrations, and exact manufacturer formatting, refer to the original PDF.

LiftMaster provides a UL 325 and ASTM F2200 Site Planning Safety Checklist for dealers and installers to document at installation: gate construction compliance (smooth bottom edges, access control clearance of 6 feet, barbed tape/wire height, separate pedestrian gate, no self-closing under gravity), swing-specific checks (pivot-to-column clearance under 4 inches or protected, open-gate clearance of at least 16 inches or protected), and general UL 325 checks (operator label current to standard, warning signs on both sides, both entrapment zones protected by two safety devices and obstruction tested).

A minimum of two independent entrapment protection devices must protect every entrapment zone. A swing gate operator will only operate with a minimum of one external device in either the open or close direction; if no entrapment zone exists in the other direction, only the inherent protection is required there. The checklist should be signed by the dealer, installer, and customer, and a photograph of the completed installation should be kept on file.

SAFETY CHECKLIST