LiftMaster LA500 Instruction Manual
This HTML resource is based on the LiftMaster LA500 installation manual for the LA500PKGUL package, LA500DC primary 24 Vdc actuator arm, LA500DCS secondary 24 Vdc actuator arm (includes a monitored retro-reflective photoelectric sensor), and related LA500UL light commercial and residential DC vehicular swing gate operator applications.
The page is designed to make the manual easier to browse, search, and reference online. For diagrams, exact dimensions, and full manufacturer formatting, download the official LA500 PDF manual.
Compatible Models
- LiftMaster LA500UL
- LA500PKGUL Single Arm Package
- LA500DC Primary 24 Vdc Actuator Arm
- LA500DCS Secondary 24 Vdc Actuator Arm
Key Applications
- Light commercial and residential vehicular swing gates
- Class I, II, III, and IV vehicular swing gate applications
- Single and dual swing gate setups (wired or wireless)
- myQ, Security+ 2.0, and Security+ 3.0 MAX / Universal accessory compatible systems
Quick Specs
| Specification | Detail |
|---|---|
| Usage classification | Class I, II, III, & IV |
| Main AC supply | 120 Vac, 2 Amps (8 Amps including accessory outlets), or 240 Vac, 1 Amp |
| System operating voltage | 24 Vdc transformer run / battery backup |
| Accessory power | 24 Vdc, 500mA max. for ON + SW (switched) |
| Solar power max | 24 Vdc at 60 watts max. |
| Maximum gate weight / length | 1600 lbs / 8 ft, 800 lbs / 16 ft, 600 lbs / 18 ft |
| 90 degree travel time | 15 to 18 seconds |
| Maximum travel range | 115 degrees |
| Maximum daily cycle rate | 300 cycles per day |
| Maximum duty cycle | Continuous |
| Operating temperature | -40°C to 60°C (-40°F to 140°F) |
Manual Sections
Cover / Overview
Page 1: Cover and Product Overview
Vehicular Swing Gate Operator Installation Manual for Models LA500PKGUL, LA500DC, LA500DCS.
LIGHT COMMERCIAL - RESIDENTIAL DC
EXTERNAL SAFETY DEVICES REQUIRED. SEE SAFETY SECTION FOR UL 325 ENTRAPMENT PROTECTION REQUIREMENTS. THIS PRODUCT MUST BE INSTALLED AND SERVICED IN ACCORDANCE WITH THIS MANUAL BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
- This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates.
- This model is intended for use in Class I, II, III, and IV vehicular swing gate applications.
- Visit LiftMaster.com to locate a professional installing dealer in your area.
- This gate operator is compatible with myQ® and Security+ 2.0® accessories and Security+ 3.0® MAX and Universal accessories.
LiftMaster, 300 Windsor Drive, Oak Brook, IL 60523.
Safety
Page 2 to 3: Safety Symbol Review, Usage Class, and UL325 Entrapment Protection Requirements
Safety Symbol and Signal Word Review
Warning symbols on mechanical and electrical hazards alert you to the risk of serious injury or death. The Caution symbol alerts you to possible damage to the gate or operator. Before installing, operating, or maintaining this operator, read and fully understand this manual and follow all safety instructions. Only a trained gate systems technician should attempt repair or service.
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Usage Class
- Class I: Residential vehicular gate for one- to four-family residences.
- Class II: Commercial/general access gate for multi-family housing, hotels, retail, or other buildings servicing the public.
- Class III: Industrial/limited access gate for factories, loading docks, or other non-public locations.
- Class IV: Restricted access gate for guarded industrial locations such as airport security areas.
UL 325 Entrapment Protection Requirements
An entrapment zone is any location between a moving gate or exposed operator component and a counter-opposing edge or surface where entrapment is possible up to 6 feet above grade. This includes any gap between the bottom of the gate and the ground greater than 4 inches and less than 16 inches, and any gap between the pivot centerline and the end of a wall, pillar, or column exceeding 4 inches.
A minimum of two independent monitored entrapment protection devices is required at each entrapment zone. This operator includes one inherent (built-in) device; the installer must add at least one additional external device per entrapment zone. Acceptable device types are inherent, LiftMaster monitored external photoelectric sensors, and LiftMaster monitored external edge sensors.
Page 4: Safety Installation Information
Gate systems are made up of many component parts, and the operator is only one of them. Installers must account for the hazards of each individual application. Pedestrians must always be provided a separate access opening located so they never come in contact with the vehicular gate during its travel. Permanently mounted access controls must sit at least 6 feet from any moving gate part. A minimum of two warning signs must be installed so at least one is visible from each side of the gate.
Page 5: Gate Construction Information
Gates should be installed according to ASTM F2200. Gates must not fall over more than 45 degrees from vertical if detached from their hardware, must have smooth bottom edges with no protrusions exceeding 0.5 inches, and must not move under gravity alone if the operator is disconnected. For Class I, II, and III swing gates, the object covered by the gate in the open position must not exceed 4 inches measured from the pivot centerline, and clearance to any fixed object must be at least 16 inches unless entrapment protection is added.
Introduction
Page 6 to 7: Carton Inventory, Optional Accessories, and Operator Specifications
The carton includes the gate operator, standard control box with two 12 Vdc 7AH batteries, two keys, post bracket, gate bracket, two warning signs, warranty card, and installation manual. The LA500DCS model additionally includes a LiftMaster monitored retro-reflective photoelectric sensor with junction box, terminal block connector, and watertight extension cable connector.
Optional accessories not included in the box: the Large Metal Control Box (Model LA500CONTXLMUL) for installations needing extra room, and the Large Metal Control Box for Solar Applications (Model XLSOLARCONTUL), which requires two 33AH batteries, a battery tray, and a solar battery harness.
Operator Specifications
Usage Classification: Class I, II, III, & IV. Main AC Supply: 120 Vac, 2 Amps (8 Amps including Accessory Outlets) OR 240 Vac, 1 Amp. System Operating Voltage: 24 Vdc Transformer Run / Battery Backup. Accessory Power: 24 Vdc, 500mA max. Solar Power Max: 24 Vdc at 60 watts max. Maximum Gate Weight/Length: 1600 lbs / 8 ft, 800 lbs / 16 ft, 600 lbs / 18 ft. 90 Degree Travel Time: 15-18 seconds. Maximum Daily Cycle Rate: 300 cycles/day. Operating Temperature: -40°C to 60°C (-40°F to 140°F). Expansion Board: Provided.
Page 8: Site Preparation and Check Your Gate
Check national and local building codes before installation. Contact underground utility locating companies before trenching, and use UL-approved conduit for low and high voltage lines. Vehicle loops, while not required, are recommended for vehicles 14 feet or longer to keep the gate open while a vehicle blocks its path.
Before installing, confirm: the gate is level, the gate and post are plumb, the gate has a smooth bottom edge with no protrusions, any wheels are removed from the bottom of the gate, the gate does not drag across the ground, and the gate swings freely on its hinges.
Installation
Page 9: Installation Tips
Do: weld a horizontal bar across the entire gate for strength, mount the operator level, leave slack in the operator cable, and install the operator at least 12 inches from the ground.
Do not: install upside down, install near sprinklers, install on uphill or downhill gates, install on pedestrian passageways, over-bend the operator cable, or weld the crossbar to just a few pickets.
Page 10 to 11: Position and Attach the Brackets
With the gate closed, measure dimension A from the hinge point and dimension B from that mark to locate the post bracket and gate bracket. The ideal measurements are A = 7-3/4 inches and B = 8-1/2 inches, though other combinations are acceptable as long as A plus B does not exceed 18 inches. There must be no more than 4 inches from the center of the hinge to the edge of the post; if the gap is larger, that area needs entrapment protection. With the gate fully open, the operator needs a minimum clearance of 11-1/4 inches.
Insert the key and turn it 180 degrees counterclockwise, then turn the release lever 180 degrees counterclockwise to put the operator in manual mode. Position the operator on the brackets, confirm it sits level, then remove it and fully weld the brackets in place. Reattach the operator to the post bracket and gate bracket with the provided hardware. For dual gate applications, repeat these steps for the second operator.
Page 12 to 13: Install the Control Box
The control box must be mounted within 5 feet of the gate operator, as high as possible for best radio reception, and level. For the standard control box, remove the expansion board before mounting to a wall, column, or post, then reinstall it once the box is secured. For post mounts, use U-bolts and rubber washers, keeping the U-bolts from protruding more than 3/4 inch to avoid shorting the control board.
The Large Metal Control Box follows the same 5-foot and leveling rules, with wall/column and post mounting options. The post mount option is not recommended for the 33AH battery application.
Page 14: Earth Ground Rod and Wiring the Operator Arm
Install the earth ground rod within 3 feet of the operator using a single, whole piece of wire, never spliced. Improper grounding reduces remote control range and increases susceptibility to lightning and surge damage.
To wire the operator arm, route the operator cable through a watertight connector into a knockout at the bottom of the control box, match wire colors to the connector labeling, and plug the connector into the GATE 1 terminal on the control board.
Page 15 to 17: Dual Gate Setup
Dual gate communication is either wired or wireless, never both at once. Wired setups keep a longer battery standby time. Wireless setups need a second control box and are paired using the LEARN button: press it once on each operator to light the XMITTER LED, press again to light the NETWORK LED, then use the OPEN test button on the primary and CLOSE test button on the secondary to complete pairing.
Wired setups run an extension cable through a junction box mounted within 3 feet of the second operator, connecting like-colored wires at a terminal block, then wiring the secondary operator into the GATE 2 terminal on the control board.
The BIPART DELAY switch controls which gate opens first and closes first, useful for overlapping decorative gates or solenoid locks, and can also synchronize the close cycle when one gate travels farther than the other.
Page 18 to 19: Install and Wire Entrapment Protection
Entrapment protection devices must be installed at every entrapment zone identified using the Site Planning Safety Checklist. The operator will not run without a minimum of one external device connected in either the open or close direction. All devices must be tested after installation.
The control board has dedicated inputs: CLOSE EYES/INTERRUPT for photoelectric sensors in the close direction, CLOSE EDGE for edge sensors in the close direction, and OPEN EYES/EDGE for sensors in the open direction. The expansion board adds EYE ONLY and EYE/EDGE inputs that can be switched to either direction. Only one monitored device may be wired to each input.
Page 20 to 21: Power Wiring
The standard control box can run on 120 Vac (factory default) or 240 Vac. Turn off AC power at the breaker before wiring, connect ground, neutral, and hot wires to the toroid transformer assembly, then plug the J15 connector into the control board. A small spark when plugging in J15 is normal. Power and control wiring must always run in separate conduits, and control wiring must use Power-Limited Circuit Cable rated CL2, CL2P, CL2R, or CL2X or better.
Page 22: Warning Signs and Finishing the Installation
Install the two required UL warning signs in plain view on both sides of the gate. To finish, turn the release lever clockwise 180 degrees to re-engage the motor, then turn the key clockwise 180 degrees to lock the release lever.
Adjustment
Page 23 to 24: Limit and Force Adjustment
Never increase force beyond the minimum needed to move the gate, and never use force to compensate for a binding or sticking gate. After any adjustment to force or travel limits, retest the safety reversal system: the gate must reverse on contact with an object.
To set initial limits: set the GATE switch to position 1, press SET OPEN and SET CLOSE together to enter limit setting mode, use the MOVE GATE buttons to drive the gate to each limit, and press the matching SET button at each position. Cycling the gate with the TEST buttons afterward sets the force automatically. Repeat for the second gate on dual setups by switching to GATE position 2.
Page 25: Fine Tune the Force and Obstruction Test
The REVERSAL FORCE dial fine-tunes force for wind and seasonal changes. If the gate stops short of a limit, increase force slightly clockwise. After every adjustment, run the obstruction test: place an object or your hand in the gate's path during the close cycle. The gate must stop and reverse on contact. If it doesn't, reduce force slightly counterclockwise. Repeat the test in the open direction.
Programming
Page 26 to 27: Programming Remote Controls
Up to 50 Security+ 2.0® remotes or KPW250 keypads, plus 2 keyless entries, can be stored in memory. To program a remote, press and release the LEARN button (the green XMITTER LED lights), then press the remote button to program within 30 seconds. Three programming options exist: single button as open only, single button as open/close/stop, or three separate buttons for open, close, and stop.
Security+ 3.0 MAX remotes (models CH361, L932M, CH382, L993M) use a different pairing sequence: put the remote into programming mode first, then press LEARN on the operator, double-press the desired remote button, and confirm the gate moves when the button is pressed again.
Page 28 to 29: Internet Gateway, Erase Codes, and CPO
The LiftMaster Internet Gateway pairs through the myQ app after connecting it to a router and powering it on; the operator beeps to confirm a successful pair.
To erase all remote codes: press LEARN, then press and hold it again for about 6 seconds until the XMITTER LED flashes. To erase limits: hold SET OPEN and SET CLOSE together for 5 seconds until both LEDs blink rapidly. Constant Pressure Override (CPO) temporarily bypasses a faulted entrapment protection device using a valid 4-digit PIN plus holding the # key, and should only be used in direct line of sight of the gate.
Operation
Page 31: Control Board Overview
The control board includes SET OPEN and SET CLOSE buttons for limits, MOVE GATE buttons for jogging the gate during setup, a BATT FAIL option switch, a BIPART DELAY switch for dual gates, a LEARN button for remotes, a TIMER-TO-CLOSE dial (0 to 180 seconds, 0 is off), a REVERSAL FORCE dial, TEST buttons for open/stop/close, status LEDs, and a diagnostics display showing operator type, firmware version, and error codes.
Page 32: Manual Release, Reset Button, and Party Mode
To release the operator manually: insert the key, turn it counterclockwise 180 degrees, then turn the release lever counterclockwise 180 degrees. To re-engage: reverse both steps. The reset button stops a moving gate, cancels the Timer-to-Close (Party Mode), and clears alarms. Party Mode can also be triggered from a KPW5 or KPW250 keypad with a valid PIN while the gate sits open with the timer running.
Page 33: Operator Alarm and Remote Control Behavior
The alarm sounds for up to 5 minutes if the operator detects an obstruction, incorrect installation, tight or broken hinges, a vehicle pushing the gate, a foreign object on the frame, or the gate hitting a curb, twice consecutively. Clear the obstruction and press reset to silence the alarm. Three short beeps during a command indicate a low battery.
With a single-button remote, pressing it opens a closed gate, stops it mid-open on a second press, and closes it on a third. The same logic applies in reverse when the gate starts open.
Accessory Wiring
Page 34 to 35: External Control Devices, Maglock, and Miscellaneous Wiring
The EXIT input is a soft open command for exit probes, telephone entry, or exit loop detectors. SHADOW holds the gate open at the limit when a loop is positioned under the gate. INTERRUPT holds the gate open and reverses a closing gate when a loop sits outside the gate. None of these inputs function as entrapment protection.
The LOCK output is a normally-closed relay contact for maglocks that activates before and during motor movement. Accessory power provides 24 Vdc at 500mA max, either switched (on during motion and for 5 seconds after) or unswitched (always on).
Expansion Board
Page 36 to 39: Expansion Board Overview and Auxiliary Relays
The expansion board adds switches for Quick Close, AC Fail, Exit Fail, Anti-Tail, two configurable auxiliary relays, and EYE/EDGE direction settings, plus inputs for loop detectors and a wireless edge kit. Auxiliary Relay settings include Open Limit Switch, Close Limit Switch, Gate Motion, Pre-Motion Delay, Power, Tamper, and Cycle Quantity Feedback, each set via a 3-position dipswitch combination.
Maintenance
Page 40: Maintenance Chart and Batteries
Check entrapment protection devices, warning signs, and the manual disconnect monthly. Inspect the gate, accessories, electrical connections, and mounting hardware every six months. Replace batteries every 3 years using only LiftMaster part 29-NP712. Always disconnect all power, including batteries, before servicing.
Troubleshooting
Page 41: Reading Diagnostic Codes
To view codes, press and hold STOP, then CLOSE, then OPEN until "Er" appears. The display cycles through up to 20 saved codes, most recent first. Press OPEN to scroll toward the most recent, CLOSE to scroll toward the oldest. Hold STOP for 6 seconds to reset the code history.
Page 43 to 45: Troubleshooting Chart
| Symptom | Possible Causes | Solutions |
|---|---|---|
| Operator does not run, diagnostic display off | No power, blown fuse, dead batteries, inoperable control board | Check AC and battery power, check fuses, charge or replace batteries, replace control board if needed |
| Control board powers up but motor does not run | Stuck reset switch, active stop input, low batteries, active open/close input, triggered entrapment device | Check the reset switch and stop button, charge or replace batteries, check all inputs for a stuck-on signal |
| Gate stops during travel and reverses immediately | Active open/close control, active loop detector, low battery voltage, triggered entrapment protection | Check inputs, confirm battery voltage is 23.0 Vdc or higher, clear obstructions and retest |
| Gate opens but will not close | Open control active, loop detector active, Fire Dept input active, TTC not set, close entrapment device active | Check all listed inputs and the Timer-to-Close setting |
| Gate closes but will not open | Active vehicle loop detector, low battery with LOW BATT set to Close | Check loop detector inputs, charge or replace batteries |
| Photoelectric or edge sensor does not stop/reverse the gate | Incorrect wiring or inoperable sensor | Check wiring, retest, replace the sensor if faulty |
| Alarm sounds for up to 5 minutes | Double entrapment detected (two obstructions in one activation) | Clear the obstruction, press reset to silence the alarm |
| Alarm beeps three times with a command | Low battery | Check AC power, charge or replace batteries |
| Remote control does not respond | Not programmed, active stop button, poor radio reception | Re-learn the remote, check the stop button, check the antenna and wiring |
| Solar operator not getting enough cycles per day | Insufficient panel wattage, excessive accessory draw, old batteries, insufficient sunlight | Add solar panels, reduce accessory load, replace batteries, or relocate panels away from obstructions |
Page 46 to 47: Diagnostic Codes Table
| Code | Meaning | Solution |
|---|---|---|
| 31 | Main control board internal error | Disconnect all power for 15 seconds, then reconnect. Replace board if it continues. |
| 32 / 33 | Linear drive disengaged (Arm 1 / Arm 2) | Disengage then re-engage the arm; check wiring and connections |
| 35 | Max-run-time exceeded | Check for an obstruction, then reprogram the limits |
| 36 / 37 | Product ID error / failure | Erase limits and reset if board was replaced, or reseat the product ID harness |
| 38 / 39 | Hard stop limit (Arm 1 / Arm 2) | Re-adjust the limit or the mounting |
| 40 / 41 | Battery overvoltage / overcurrent | Check the harness; confirm correct battery voltage for the system |
| 42 | No battery at boot up | Check battery connections; replace if depleted below 20V (24V system) or 10V (12V system) |
| 43 / 44 / 45 | Exit / Shadow / Interrupt loop error | Check loop wiring for a short or open connection |
| 46 | Wireless edge battery low | Replace batteries in the wireless edge |
| 60 | Minimum entrapment protection devices not installed | Review entrapment protection connections; at least one external device is required |
| 61-66 | Entrapment input held more than 3 minutes (main or expansion board) | Check wiring, alignment, and obstruction on the relevant input |
| 91-94 | Force or RPM/stall reversal (Operator 1 / 2) | Check for obstruction; confirm mechanical assembly is engaged and free to move |
| 99 | Normal operation | No action required |
Appendix
Page 48 to 51: Installation Types and Solar Panels
Covers Pull-to-Open and Push-to-Open configurations for both column and post installations, with reinforcement guidance for each.
Solar installations require either the Large Metal Control Box for Solar Applications with two 33AH batteries, or the Standard Control Box for Solar Applications with two 7AH batteries, paired with a minimum of two and maximum of six 10W solar panels (model SP10W12V) and a solar battery harness. Solar panels must face south and sit clear of shade. Solar zones are rated by average daily sunlight (6, 4, or 2 hours), and cycles per day vary by zone, panel wattage, and battery capacity. Solar installations are not supported in far northern climates due to reduced winter sunlight.
Page 55 to 56: Limit Setup with a Remote Control and SAMS Wiring
Limits can also be set using a 3-button remote programmed for OPEN, CLOSE, and STOP (Security+ 2.0 model 813LMX recommended). Enter limit setting mode on the control board, then jog the gate to each position using the remote's OPEN and CLOSE buttons, pressing STOP to confirm each position before pressing OPEN or CLOSE again to lock it in.
The Sequenced Access Management System (SAMS) uses programmable relays to determine the order in which multiple control devices operate across an opening, such as a swing gate and barrier gate combination.
Repair Parts
Page 57 to 58: Standard and Large Metal Control Box Parts
Key replacement parts include the control board (K1D8388-1CC), expansion board (K1D8387-1CC), piezo alarm (K94-36296), reset switch with product ID (K94-36408-1), toroidal transformer kits, and single 7AH battery (29-NP712). Gate operator arm parts include the primary arm (LA500DC), rear connector with pin, release keys, steel bracket mounting plates, and junction box with cable.
Wiring Diagram
Page 59 to 60: Standard and Large Metal Control Box Wiring
Full wiring diagrams cover the standard and large metal control boxes, including photoelectric sensor and edge sensor terminals, hard-wired open/close/stop and exit inputs, battery connections, transformer wiring, solar panel wiring, and the expansion board connection. See the official PDF for the complete schematic.
Accessories
Page 61 to 62: Entrapment Protection, Remote Controls, and Miscellaneous
Available entrapment protection accessories include the monitored through-beam photoelectric sensor (LMTBUL), monitored retro-reflective photoelectric sensor (LMRRUL), Commercial Protector System (CPS-UN4, CPSUN4G), monitored wireless edge kit (LMWEKITU), and monitored wireless edge transmitter (LMWETXU). Remote control options range from the 3-button 893MAX to the keyless entry 878MAX and the 3-button DIP remote 813LMX. Other accessories include the STAR1000 commercial receiver, LOOPDETLM plug-in loop detector, CP4 vehicle sensing probe, MG1300 magnetic gate lock, KPW250 wireless keypad, and 828LM Internet Gateway.
Warranty
Page 63: LiftMaster 2 Year Limited Warranty
LiftMaster warrants this product against defects in materials and workmanship for 2 years from the date of purchase, contingent on following the installation, operation, maintenance, and testing instructions in this manual. The warranty does not cover gate or gate hardware issues, damage from improper installation or care, labor for reinstalling repaired units, or battery replacement. Call 1-800-528-2806 for warranty service before dismantling the product.
Common Questions
Why won't my LiftMaster LA500 gate operator run at all?
Check for power first. This can mean no AC power reaching the control board, a blown fuse, or dead batteries if you're running on battery power only. If the diagnostic display isn't lit, start with the power source and fuses before assuming the control board has failed.
The control board powers up but the LA500 motor won't move the gate. What's wrong?
This usually points to a stuck reset switch, an active stop button, an open or close input that's stuck on, or an entrapment protection device sensing an obstruction that isn't really there. Check each input for a stuck signal before replacing any parts.
How many entrapment protection devices does the LA500 need?
UL 325 requires two independent monitored entrapment protection devices for each entrapment zone. The LA500 has one built-in device, so you must add at least one more external device, such as a photoelectric sensor or edge sensor, per entrapment zone.
How do I set the open and close limits on a LiftMaster LA500?
Set the GATE switch to position 1, then press and release the SET OPEN and SET CLOSE buttons at the same time to enter limit setting mode. Use the MOVE GATE buttons to move the gate to each limit, pressing SET OPEN or SET CLOSE as you reach each position, then cycle the gate with the test buttons to automatically set the force.
My LA500 gate reverses on its own without hitting anything. How do I fix it?
This is almost always a force setting that's too sensitive, or low battery voltage. Turn the REVERSAL FORCE dial slightly clockwise to increase force, then run the obstruction test again. Never increase force beyond the minimum needed to move the gate.
How do I program a new remote control to the LA500?
Press and release the LEARN button on the control board. The green XMITTER LED will light up. Then press the button on your remote you want to program. The operator beeps and the LED turns off once programming is successful.
What does it mean when the LA500 alarm sounds for several minutes?
A long alarm, up to 5 minutes, means the operator detected a double entrapment condition, meaning two obstructions within a single gate cycle. Clear the obstruction, then press the reset button to silence the alarm and reset the operator.
What is diagnostic code 60 on a LiftMaster LA500?
Code 60 means the minimum number of monitored entrapment protection devices is not installed. The operator requires at least one external device connected in either the open or closed direction before it will run.
How often should the LA500 be tested and serviced?
Entrapment protection devices, the manual disconnect, and warning signs should be checked monthly. The gate itself, accessories, wiring, and mounting hardware should be inspected every six months. Batteries should be replaced every 3 years using only LiftMaster part 29-NP712.
Can the LA500 be used on a pedestrian gate?
No. The LA500 is designed exclusively for vehicular gates. Pedestrians must be provided with a completely separate access point, positioned so they never come into contact with the moving vehicular gate at any point in its travel.
Download the Official LiftMaster LA500 PDF Manual
Use the PDF below for the original manufacturer diagrams, tables, templates, and complete official formatting.
Download Official PDF Manual