Compatible Models
- LiftMaster RSW12UL Residential DC Vehicular Swing Gate Operator
Key Applications
- Residential and light-duty vehicular swing gates, concrete pad mount
- Class I and II vehicular swing gate applications
- Single and dual swing gate setups (wired or wireless)
- 120 Vac or solar powered installations
- MyQ and Security+ 2.0 accessory compatible systems
Quick Specs
| Specification | Detail |
|---|---|
| Usage classification | Class I & II |
| Main AC supply | 120 Vac, 0.5 Amps (6.5 Amps including accessory outlets) |
| System operating voltage | 12 Vdc battery run / battery backup |
| Accessory power | 12 Vdc, 500mA max. for ON + SW (switched) |
| Solar power max | 12 Vdc at 30 watts max. |
| Maximum gate weight / length | 1000 lbs / 6 ft, 800 lbs / 8 ft, 700 lbs / 10 ft, 600 lbs / 12 ft, 400 lbs / 16 ft |
| 90 degree travel time | Less than 17 seconds |
| Maximum travel range | 115 degrees |
| Maximum daily cycle rate | 250 cycles per day |
| Maximum duty cycle | Continuous |
| Operating temperature | Without heater: -20°C to 60°C (-4°F to 140°F). With optional heater: -40°C to 60°C (-40°F to 140°F) |
| Expansion board | Optional |
Manual Sections
Cover / Overview
Page 1: Cover and Product Overview
Residential DC Vehicular Swing Gate Operator Installation Manual for Model RSW12UL.
- This product is to be installed and serviced by a trained gate systems technician only.
- This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates.
- This model is intended for use in Class I and II vehicular swing gate applications.
- Visit LiftMaster.com to locate a professional installing dealer in your area.
- This gate operator is compatible with MyQ® and Security+ 2.0® accessories.
LiftMaster, 300 Windsor Drive, Oak Brook, IL 60523.
Safety
Page 2 to 3: Safety Symbol Review, Usage Class, and UL325 Entrapment Protection Requirements
Warning symbols on mechanical and electrical hazards alert you to the risk of serious injury or death. Before installing, operating, or maintaining this operator, read and fully understand this manual and follow all safety instructions. Only an Authorized Service Technician should attempt repair or service.
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Usage Class
- Class I: Residential vehicular gate for one- to four-family residences.
- Class II: Commercial/general access gate for multi-family housing, hotels, retail, or other buildings servicing the public.
UL 325 Entrapment Protection Requirements
An entrapment zone is any location between a moving gate or exposed operator component and a counter-opposing edge or surface where entrapment is possible up to 6 feet above grade. This includes any gap between the bottom of the gate and the ground greater than 4 inches and less than 16 inches, and any gap between the pivot centerline and the end of a wall, pillar, or column exceeding 4 inches.
A minimum of two independent monitored entrapment protection devices is required at each entrapment zone. This operator includes one inherent (built-in) device; the installer must add at least one additional external device per entrapment zone. Acceptable device types are inherent, LiftMaster monitored external photoelectric sensors, and LiftMaster monitored external edge sensors.
Page 4: Safety Installation Information
Gate systems are made up of many component parts, and the operator is only one of them. Installers must account for the hazards of each individual application. Pedestrians must always be provided a separate access opening located so they never come in contact with the vehicular gate during its travel. Permanently mounted access controls must sit at least 6 feet from any moving gate part. A minimum of two warning signs must be installed so at least one is visible from each side of the gate. Stop and/or Reset controls must be located in the line-of-sight of the gate.
Page 5: Gate Construction Information
Gates should be installed according to ASTM F2200. Gates must not fall over more than 45 degrees from vertical if detached from their hardware, must have smooth bottom edges with no protrusions exceeding 0.5 inches, and must not move under gravity alone if the operator is disconnected. The object covered by the gate in the open position must not exceed 4 inches measured from the pivot centerline, and clearance to any fixed object must be at least 16 inches unless entrapment protection is added.
Introduction
Page 6 to 7: Carton Inventory and Operator Specifications
The carton includes the gearmotor operator, arm assembly, cover (rear and front), LiftMaster Monitored Retro-Reflective Photoelectric Sensor (Model LMRRUL), two keys, two warning signs and warranty card, and one 12 Vdc 7AH battery. Documentation packet and hardware bag are not shown.
Operator Specifications
Usage Classification: Class I & II. Main AC Supply: 120 Vac, 0.5 Amps (6.5 Amps including Accessory Outlets). System Operating Voltage: 12 Vdc Battery Run / Battery Backup. Accessory Power: 12 Vdc, 500mA max. Solar Power Max: 12 Vdc at 30 watts max. Maximum Gate Weight/Length: 1000 lbs / 6 ft, 800 lbs / 8 ft, 700 lbs / 10 ft, 600 lbs / 12 ft, 400 lbs / 16 ft. 90 Degree Travel Time: less than 17 seconds. Maximum Daily Cycle Rate: 250 cycles/day. Operating Temperature: -20°C to 60°C (-4°F to 140°F) without heater, -40°C to 60°C (-40°F to 140°F) with optional heater. Expansion Board: Optional.
Page 8: Site Preparation and Check Your Gate
Check national and local building codes before installation. Trench and install conduit before pouring the concrete pad; contact underground utility locating companies first, and use UL-approved conduit. Vehicle loops, while not required, are recommended for vehicles 14 feet or longer to keep the gate open while a vehicle blocks its path.
Before installing, confirm: the gate is level, the gate and post are plumb, the gate has a smooth bottom edge with no protrusions, any wheels are removed from the bottom of the gate, the gate does not drag across the ground, and the gate swings freely on its hinges.
Installation
Page 9 to 10: Step 1 - Determine Location for Concrete Pad and Operator
For compact installation (where the operator arm would hit an obstruction with the gate fully open), refer to the Appendix for installation steps 1 to 4. DO NOT run the operator until instructed.
Refer to the standard installation chart to determine the concrete pad measurements and location; dimensions A through E are measured from the center of one pivot point to the center of another. If the gate is longer than 18 feet, use the alternate dimension chart. As a rule of thumb, the distance between the gate and the concrete pad is always 10 inches less than dimension D.
NOTE: There should only be a maximum of 4 inches from the center of the hinge to the edge of the post or column; if the distance is greater, entrapment protection for that area is required.
Page 11: Step 2 - Concrete Pad and Operator Attachment
Check national and local building codes before installation. Lift the operator using its handle to avoid damage. 1. Install the electrical conduit. 2. Pour a concrete pad, reinforced concrete recommended, at least 6 inches above the ground and deeper than the frost line, tall enough to avoid flooding. 3. Secure the operator to the concrete pad with appropriate fasteners.
Page 12: Step 3 - Position the Gate Bracket and Step 4 - Adjust the Operator Arm Length
It may be necessary to attach horizontal reinforcement to the gate before attaching the gate bracket. 1. Position the operator arm onto the output shaft so the pin slides into the slot. 2. Measure along the gate length from the gate hinge center per the dimension chart. 3. Measure up from the concrete pad to the gate hinge position. 4. Confirm the operator arm is level and tack weld the gate bracket in place, using the set screws on the arm to temporarily hold it while measuring.
The arm length can be adjusted if necessary, keeping both sections proportional. Close the gate and measure the distance from the gate bracket to the output shaft center (distance E). Open the gate 90 degrees without letting the arms scissor, then measure both arm sections (C and D); the arm lengths are correct as long as C + D = E.
Page 13: Step 5 - Secure the Operator Arm
Once arm measurements are verified: 1. Weld the gate bracket to the gate. 2. Weld the short arm section. 3. Weld the long arm section. 4. Remove the set screws, completely welding around the outer tubing and bracket. 5. Adjust the nuts on the operator arm so it fits snug on the output shaft while still able to swivel (handle in a 90 degree position). 6. Tighten the handle by pushing it down and test that the arm does not slip on the output shaft. 7. Remove the vent plug pin on both the top and bottom gear boxes.
Page 14 to 16: Step 6 - Install and Wire Entrapment Protection
WARNING: ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone. Entrapment protection devices MUST be located to protect in BOTH the open and close gate cycles, between the moving gate and RIGID objects such as posts, walls, pillars, columns, or the operator itself.
Entrapment protection MUST be installed per UL 325 requirements: swing gate operators require the installation of the first external monitored entrapment protection device to function. Every installation is unique, so ensure ALL entrapment zones are protected. Test ALL entrapment protection devices after completing installation.
The control board has dedicated inputs: CLOSE EYES/INTERRUPT for photoelectric sensors in the close direction, CLOSE EDGE for edge sensors in the close direction, and OPEN EYES/EDGE for sensors in the open direction. An optional expansion board adds EYE ONLY and EYE/EDGE inputs that can be switched to either direction. Only one monitored device may be wired to each input.
Page 16: Step 7 - Earth Ground Rod and Step 8 - Power Wiring
Install the earth ground rod within 3 feet of the operator using a single, whole piece of wire, never spliced. Improper grounding reduces remote control range and increases susceptibility to lightning and surge damage.
The operator can be wired for 120 Vac or a solar panel (not provided). The battery is charged in the circuit by the integrated transformer. The operator requires one 7AH battery (provided) or one 33AH battery; the 33AH application requires the 33AH wire harness (Model K94-37236).
Page 17: 33AH Battery Wiring
To use a 33AH battery in place of the 7AH battery, install the 33AH wire harness: connect the red (+) wire from the new harness to the positive terminal, and the black (-) wire to the negative terminal, following the harness instructions for the J15 plug connections.
Page 18 to 19: Step 9 - Dual Gate Setup
Dual gate communication is either wired or wireless, never both at once. Wired setups keep a longer battery standby time. Wireless setups are paired using the LEARN button: press it once on each operator to light the XMITTER LED, press again to light the NETWORK LED, then use the OPEN test button on the primary and CLOSE test button on the secondary to complete pairing.
Wired setups use a shielded twisted pair cable run between the Com Link terminals on each control board (Com Link A to Com Link A, Com Link B to Com Link B), with the cable shield grounded to the chassis of one operator. 22AWG cable is rated up to 200 feet; 18AWG up to 1000 feet, both at 30 Volt minimum.
The BIPART DELAY switch controls which gate opens first and closes first for overlapping decorative gates or solenoid locks, and can also synchronize the close cycle when one gate travels farther than the other by setting both operators to ON.
Page 20: Step 10 - Install the Cover
Before installing the cover, adjust the limits and force per the Adjustment section. The cover has two pieces: a rear cover and a front cover, with an access door for the reset switch that can be locked with the key.
1. Remove the operator arm from the output shaft by releasing the handle. 2. Align the rear cover tabs with the chassis slots and place the cover over the operator. 3. Secure both sides of the rear cover with the lead-in screws. 4. Reattach the operator arm, making sure the pin fits the slot, and secure by pushing the handle down. 5. Place the operator arm cover over the arm. 6. Align and secure the front cover to the chassis and to the rear cover.
Adjustment
Page 21: Limit and Force Adjustment
Never increase force beyond the minimum needed to move the gate, and never use force to compensate for a binding or sticking gate. After any adjustment to force or travel limits, retest the safety reversal system: the gate must reverse on contact with an object.
To set initial limits: press SET OPEN and SET CLOSE together to enter limit setting mode, use the MOVE GATE buttons to drive the gate to each limit, and press the matching SET button at each position. Cycling the gate afterward sets the force automatically. The operator exits limit setting mode automatically once both limits are set.
Page 22: Obstruction Test
The REVERSAL FORCE dial fine-tunes force for wind and seasonal changes. If the gate stops short of a limit, increase force slightly clockwise. After every adjustment, run the obstruction test: place an object between the open gate and a rigid structure, without triggering external entrapment devices. Run the gate in the close direction; it should stop and reverse on contact. If it doesn't, reduce force slightly counterclockwise. Repeat the test in the open direction.
Programming
Page 23: Programming Remote Controls
Up to 50 Security+ 2.0® remotes or KPW250 keypads, plus 2 keyless entries, can be stored in memory. To program a remote, press and release the LEARN button (the green XMITTER LED lights), then press the remote button to program within 30 seconds. Three programming options exist: single button as open only, single button as open/close/stop, or three separate buttons for open, close, and stop.
Page 24: Internet Gateway, CPO, and Gate Hold Open
The LiftMaster Internet Gateway pairs through an online account at myliftmaster.com after connecting it to a router and powering it on, then pressing LEARN twice on the primary operator.
Constant Pressure Override (CPO) is for use with KPW5 and KPW250 keypads, temporarily bypassing a faulted entrapment protection device using a valid 4-digit PIN plus holding the # key. The Gate Hold Open feature disables the Timer-to-Close and keeps the gate at the open limit using the same PIN entry method, or a programmed remote to restart the gate.
To erase all remote codes: press LEARN, then press and hold it again for about 6 seconds until the XMITTER LED flashes. To erase limits: hold SET OPEN and SET CLOSE together for 5 seconds until both LEDs blink rapidly.
Operation
Page 25: Control Board Overview
The control board includes SET OPEN and SET CLOSE buttons for limits, MOVE GATE buttons for jogging the gate during setup, a BATT FAIL option switch, a BIPART DELAY switch for dual gates, a LEARN button for remotes, a TIMER-TO-CLOSE dial (0 to 180 seconds, 0 is off), a REVERSAL FORCE dial, TEST buttons for open/stop/close, status LEDs, a diagnostics display showing operator type, firmware version, and error codes, and a BACKDRIVE switch: set to MANUAL, the gate can be pushed open or closed by hand during a power loss; set to SECURE, the gate is difficult to push open or closed.
Page 26: Manual Disconnect, Reset Switch, Operator Alarm, and Remote Control
Press the reset switch to RESET/DISCONNECT, then release the handle on the operator arm to allow the gate to be opened and closed manually (on dual gates, release the handle on both operators). To resume normal function, tighten the handle by pushing it down.
The reset switch, located on the front of the operator, stops a moving gate like a stop button, and also energizes the solenoid lock and disables the maglock for two minutes.
The alarm sounds for up to 5 minutes if the operator detects an obstruction, incorrect installation, tight or broken hinges, a vehicle pushing the gate, a foreign object on the frame, or the gate hitting a curb, twice consecutively. Clear the obstruction and press reset to silence the alarm. Three short beeps during a command indicate a low battery.
With a single-button remote, pressing it opens a closed gate, stops it mid-open on a second press, and closes it on a third. The same logic applies in reverse when the gate starts open.
Accessory Wiring
Page 27 to 28: External Control Devices, Locks, and Miscellaneous Wiring
The EXIT input is a soft open command for exit probes, telephone entry, or exit loop detectors. SHADOW holds the gate open at the limit when a loop is positioned under the gate. INTERRUPT holds the gate open and reverses a closing gate when a photoelectric sensor or loop sits outside the gate.
The maglock output is a normally-closed relay contact that activates before and during motor movement. The Fire Department Open input acts as a hard open, overriding external safeties. Accessory power provides 12 Vdc at 500mA max, either switched (on during motion and for 5 seconds after) or unswitched (always on).
Maintenance
Page 29 to 30: Maintenance Chart and Batteries
Check entrapment protection devices and the gate monthly. Inspect the manual disconnect, sprockets and chains, accessories, electrical connections, chassis mounting bolts, and the operator every six months. Replace the battery every 3 years using only LiftMaster part 29-NP712. Always disconnect all power, including the battery, before servicing; the AC Power switch only disconnects AC power, not battery power.
The operator comes with one 7AH battery. One 33AH battery (A12330SGLPK) with the 33AH Battery Harness (K94-37236) and an additional battery tray (K10-36183) may be used in place of the 7AH battery.
Troubleshooting
Page 31: Reading Diagnostic Codes
To view codes, the display shows the code sequence number followed by the code itself. The display cycles through up to 20 saved codes, most recent first. Press and release STOP to exit; the display also times out after two minutes. To reset the code history, press and hold STOP for six seconds until "Er" then "CL" alternate, then release.
Page 35 to 37: Troubleshooting Chart
| Symptom | Possible Causes | Solutions |
|---|---|---|
| Operator does not run, diagnostic display off | No power, blown fuse, dead battery, defective control board | Check AC and battery power, check fuses, charge or replace the battery, replace control board if needed |
| Control board powers up but motor does not run | Stuck reset switch, active stop input, low battery, active open/close input, triggered entrapment device | Check the reset switch and stop button, charge or replace the battery, check all inputs for a stuck-on signal |
| Gate moves but cannot set correct limits, or does not fully open/close when setting limits | Gate not moving to a limit position, gate too difficult to move | Use manual disconnect, confirm the gate moves easily through its entire range limit to limit, repair the gate as needed |
| Gate stops during travel and reverses immediately | Active open/close control, active loop detector, low battery voltage | Check inputs, confirm battery voltage is sufficient, clear obstructions and retest |
| Gate opens but will not close | Open control active, loop detector active, low battery, Fire Dept input active, TTC not set, close entrapment device active | Check all listed inputs, battery power, and the Timer-to-Close setting |
| Interrupt loop does not stop/reverse the gate | Detector setup incorrect, defective detector | Review settings, replace detector |
| Photoelectric or edge sensor does not stop/reverse the gate | Incorrect wiring or defective sensor | Check wiring, retest, replace the sensor if faulty |
| Alarm sounds for up to 5 minutes | Double entrapment detected (two obstructions in one activation) | Clear the obstruction, press reset to silence the alarm |
| On dual-gate system, incorrect gate opens/closes first | Incorrect Bipart switch setting | Set Bipart switch ON on the operator that opens second and OFF on the operator that opens first |
| Solar operator not getting enough cycles per day | Insufficient panel wattage, excessive accessory draw, old battery, insufficient sunlight | Add solar panels, reduce accessory load, replace the battery, or relocate panels away from obstructions |
Page 32 to 34: Diagnostic Codes Table
| Code | Meaning | Solution |
|---|---|---|
| 31 | Main control board internal failure | Disconnect all power for 15 seconds, then reconnect. Replace board if it continues. |
| 35 | Max-run-time exceeded | Check for an obstruction, then reprogram the limits |
| 36 / 37 | Product ID error / failure | Erase limits and reset if board was replaced, or reseat the product ID harness |
| 38 | Hard stop limit (Arm 1) | Re-adjust the limit or the mounting |
| 40 / 41 | Battery overvoltage / overcurrent | Check the harness; confirm correct battery voltage for the system |
| 42 | No battery at boot up | Check battery connections; replace if depleted below the minimum voltage for the system |
| 43 / 44 / 45 | Exit / Shadow / Interrupt loop error | Check loop wiring for a short or open connection |
| 46 | Wireless edge battery low | Replace batteries in the wireless edge |
| 53 | Brownout occurred | Review power supply and wiring; allow time for a fresh boot on power cycle |
| 54 | Wireless second operator communication error | Check the second operator for power; deactivate and re-learn the wireless feature if needed |
| 60 | Minimum entrapment protection devices not installed | Review entrapment protection connections; at least one external device is required |
| 61-68 | Entrapment input held, or wireless edge issue | Check wiring, alignment, and obstruction on the relevant input |
| 69-75 | Entrapment device triggered, causing reversal or preventing close/open | No action required if an obstruction occurred; otherwise check alignment, inputs, and wiring |
| 80-84 | Communication fault between operators or boards, or non-monitored device detected | Check communication method, power, and connections; confirm connected devices are monitored |
| 91 | Force reversal (Operator 1) | Check for obstruction; confirm mechanical assembly is engaged and free to move |
| 99 | Normal operation | No action required |
Appendix
Page 38: Dual Gate Settings and Types of Installations
For dual gate installations, the manual recommends setting all accessories and board configurations on the primary operator. A standard installation mounts the operator on its own concrete pad beside the gate post; a compact installation is used when the operator arm would hit an obstruction with the gate fully open.
Page 39 to 40: Compact Installation Steps 1 to 4
The compact installation variant covers determining the concrete pad location, pad and operator attachment, shortening the operator arm, and positioning the gate bracket, following the same general sequence as the standard installation but with adjusted dimensions for tighter clearance.
Page 41 to 44: Step 8 - Solar Panels
Solar panels are not provided. Requirements include a minimum of one and maximum of three 10W solar panels (Model SP10W12V) in parallel, and either a 7AH or 33AH battery. A heater cannot be used with a solar application. Solar installations are not supported in northern climates or areas with heavy fog, lake effect snow, or rain. Panels must be mounted facing due south, clear of shade, using the provided angle bracket.
Page 45: Limit Setup with a Remote Control
Requires a 3-button remote programmed for OPEN, CLOSE, and STOP. With the gate closed, press SET OPEN and SET CLOSE together to enter limit setting mode, then jog the gate to each position using the remote's OPEN and CLOSE buttons, pressing STOP to confirm each position before pressing OPEN or CLOSE again to lock it in. Cycling the gate afterward sets the force automatically.
Wiring Diagram
Page 46: Wiring Diagram
WARNING: To protect against fire and electrocution, DISCONNECT power (AC or solar and battery) BEFORE installing or servicing the operator. Replace fuses ONLY with a fuse of the same type and rating. The full wiring diagram covers the control board, photoelectric sensor and edge sensor terminals, hard-wired open/close/stop and exit inputs, battery connections, and power wiring.
Repair Parts
Page 47: Repair Parts
Parts not shown in the diagram: Wiring Harness with product ID assembly (K94-37336), Battery Harness for 7AH batteries (K94-37230), and Battery Harness for 33AH batteries (K94-37236).
Accessories
Page 48 to 49: Entrapment Protection, Remote Controls, and Miscellaneous
Available entrapment protection accessories include the monitored through-beam photoelectric sensor (LMTBUL), monitored retro-reflective photoelectric sensor (LMRRUL), Commercial Protector System (CPS-UN4, CPSUN4G), monitored wireless edge kit (LMWEKITU), and monitored wireless edge transmitter (LMWETXU). Remote control options range from the 3-button 893MAX to the keyless entry 877MAX and the universal 811LM/813LM remotes.
Other accessories include the STAR1000 commercial receiver, LOOPDETLM plug-in loop detector, CP3 vehicle sensing probe, MG1300 magnetic gate lock, KPW250 wireless keypad, 828LM Internet Gateway, and the optional heater accessory.
Warranty
Page 50: LiftMaster Three Year Limited Warranty
LiftMaster warrants this product against defects in materials and workmanship for 3 years from the date of purchase, contingent on following the installation, operation, maintenance, and testing instructions in this manual. The warranty does not cover gate or gate hardware issues, damage from improper installation or care, labor for reinstalling repaired units, or battery replacement. Call 1-800-528-2806 for warranty service before dismantling the product.
Common Questions
Why won't my LiftMaster RSW12UL gate operator run at all?
Check for power first. This can mean no AC power reaching the control board, a blown fuse, or a dead battery if you're running on battery power only. If the diagnostic display isn't lit, start with the power source and fuses before assuming the control board has failed.
How many entrapment protection devices does the RSW12UL need?
UL 325 requires two independent monitored entrapment protection devices for each entrapment zone. The RSW12UL has one built-in device, so you must add at least one more external device, such as a photoelectric sensor or edge sensor, per entrapment zone.
How do I set the open and close limits on a LiftMaster RSW12UL?
Press and release the SET OPEN and SET CLOSE buttons at the same time to enter limit setting mode. Use the MOVE GATE buttons to move the gate to each limit, pressing SET OPEN or SET CLOSE as you reach each position, then cycle the gate to automatically set the force.
What is the BACKDRIVE switch on the RSW12UL control board?
The BACKDRIVE switch controls how the gate behaves during a power loss. Set to MANUAL, the gate can be pushed open or closed by hand. Set to SECURE, the gate becomes difficult to push open or closed if AC and battery power are both lost.
How do I program a new remote control to the RSW12UL?
Press and release the LEARN button on the control board. The green XMITTER LED will light up. Then press the button on your remote you want to program. The operator beeps and the LED turns off once programming is successful.
What does it mean when the RSW12UL alarm sounds for several minutes?
A long alarm, up to 5 minutes, means the operator detected a double entrapment condition, meaning two obstructions within a single gate cycle. Clear the obstruction, then press the reset switch to silence the alarm and reset the operator.
What is diagnostic code 60 on a LiftMaster RSW12UL?
Code 60 means the minimum number of monitored entrapment protection devices is not installed. The operator requires at least one external device connected in either the open or closed direction before it will run.
How often should the RSW12UL be tested and serviced?
Entrapment protection devices and the gate itself should be checked monthly. The manual disconnect, sprockets and chains, accessories, electrical connections, chassis mounting bolts, and the operator should be inspected every six months. The battery should be replaced every 3 years using only LiftMaster part 29-NP712.
Can the RSW12UL run on solar power?
Yes. The RSW12UL supports solar power up to 12 Vdc at 30 watts max, using a minimum of one and maximum of three 10W solar panels in parallel, paired with a 7AH or 33AH battery. A heater cannot be used in a solar application.
What is the maximum gate weight the RSW12UL can handle?
The RSW12UL is rated from 1000 lbs at 6 feet down to 400 lbs at 16 feet, depending on gate length. It is approved for Class I and II vehicular swing gate applications.