BEA FALCON EX Industrial Motion Sensors
Motion Sensor with Explosion-Proof/Flame-Proof Housing
BEA’s FALCON EX combines a microwave activation sensor with an explosion-proof / flame-proof housing, which is ideal for use in unique environments such as chemical manufacturing, petroleum refining, and agriculture.
The FALCON EX can be mounted from 11 ½ feet to 23 feet to fit any industrial application. For lower mounting heights, BEA’s FALCON EX XL can be mounted from 6 ½ feet to 11 ½ feet. The FALCON EX WIDE is available for wide detection fields, with a mounting height range of 11 ½ feet to 21 feet.
The explosion-proof / flame-proof housing is a NEMA 4X, water-proof rated enclosure designed as an IP66 housing. This housing achieves UL Class I, Div. 1, Groups B, C, D; Class II, Div. 1 & 2, Groups E, F, G; and Class III.
Features
- Energy savings - Bidirectional, unidirectional approach, and unidirectional depart microwave detection options.
- Adjustable detection settings - Six modes of detection filtering for pedestrian and parallel traffic rejection.
- Easy to program - Remote control programming enables users to quickly and safely make changes from the ground.
- Explosion-proof and highly durable - Explosion-proof / flame-proof housing weighs 11 pounds.
- 10FALCONEX100 - Standard mounting heights w/ 100 ft. cable
- 10FALCONEXXL100 - Low mounting heights w/ 100 ft. cable
Specifications
- Technology: Microwave Doppler Radar
- Radiated Frequency: 24.150 GHz
- Transmitter Radiated Frequency: < 20 dBm EIRP
- Radiated Power Density: < 5 mW / cm²
- Detection Mode: Motion
- Detection Zone
- FALCON EX: 13’ × 16’ @ 16’
- FALCON EX XL: 13’ × 61/2’ @ 81 ⁄5’
- FALCON EX WIDE: 30’ × 11’ @ 21’ Typical at 30° and field size 9
- Tilt Angles: -90 – 30° in elevation
- Output - Relay (free of potential change-over contact)
- Max. Contact Voltage: 42 VAC / VDC
- Max. Contact Current: 1 A (resistive)
- Max. Switching Power: 30 W (DC); 60 VA (AC)
- Minimum Detection Speed: 2 in / s
- Mains Frequency: 50 – 60 Hz
- Supply Voltage: 12 – 24 VAC; ±10%; 12 – 24 VDC; 30% / -10%
- Maximum Power Consumption: < 2 W
- Mounting Height
- FALCON EX: 11 1/2 – 23’
- FALCON EX XL: 6 1/2 – 11 1/2’
- FALCON EX WIDE: 11 1/2 – 21’
- Dimensions: Housing & Bracket - 5 1/2” (L) × 7 1/2” (W) × 9” (H)
- Electrical Access: NPT Pipe Thread - 3/4”
- Weight: 10 lbs.
- Cable Length: See User’s Guide for reference (Housing); Powder-coated steel (Bracket)
- Materials: Copper-free Aluminum / Aluminum
- Temperature Range: -22 – 140 °F
- Housing Certification: See User’s Guide
- Norm Conformity
- EMC: 2004 / 108 / EC
- R&TTE: 1999 / 5 / EC
Product Literature